Janet Hanley

Janet Hanley

Auto-generated profile, based on publicly available information

Janet Hanley

Edinburgh Napier University, School of Health and Social Science, Sighthill Campus, Edinburgh EH11 4BN

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2013 in BMJ
Verified
Journal Article
Open access
PDF file
HPHilary Pinnock
Hilary Pinnock
JHJanet Hanley
Janet Hanley
LMLucy McCloughan
Lucy McCloughan
ATAllison Todd
Allison Todd
AKAshma Krishan
Ashma Krishan
BMBrian McKinstry
Brian McKinstry
Objective To test the effectiveness of telemonitoring integrated into existing clinical services such that intervention and control groups have access to the same clinical care. Design Researcher blind, multicentre, randomised controlled trial. Setting UK primary care (Lothian, Scotland). Participants Adults with at least one admission for chronic obstructive pulmonary disease (COPD) in the year before randomisation. We excluded people who had other significant lung disease, who were unable to provide informed consent or complete the study, or who had other significant social or clinical problems. Interventions Participants were recruited between 21 May 2009 and 28 March 2011, and centrally randomised to receive telemonitoring or conventional self monitoring. Using a touch screen, telemonitoring participants recorded a daily questionnaire about symptoms and treatment use, and monitored oxygen saturation using linked instruments. Algorithms, based on the symptom score, generated alerts if readings were omitted or breached thresholds. Both groups received similar care from existing clinical services. Main outcome measures The primary outcome was time to hospital admission due to COPD exacerbation up to one year after randomisation. Other outcomes included number and duration of admissions, and validated questionnaire assessments of health related quality of life (using St George’s respiratory questionnaire (SGRQ)), anxiety or depression (or both), self efficacy, knowledge, and adherence to treatment. Analysis was intention to treat. Results Of 256 patients completing the study, 128 patients were randomised to telemonitoring and 128 to usual care; baseline characteristics of each group were similar. The number of days to admission did not differ significantly between groups (adjusted hazard ratio 0.98, 95% confidence interval 0.66 to 1.44). Over one year, the mean number of COPD admissions was similar in both groups (telemonitoring 1.2 admissions per person (standard deviation 1.9) v control 1.1 (1.6); P=0.59). Mean duration of COPD admissions over one year was also similar between groups (9.5 days per person (standard deviation 19.1) v 8.8 days (15.9); P=0.88). The intervention had no significant effect on SGRQ scores between groups (68.2 (standard deviation 16.3) v 67.3 (17.3); adjusted mean difference 1.39 (95% confidence interval −1.57 to 4.35)), or on other questionnaire outcomes. Conclusions In participants with a history of admission for exacerbations of COPD, telemonitoring was not effective in postponing admissions and did not improve quality of life. The positive effect of telemonitoring seen in previous trials could be due to enhancement of the underpinning clinical service rather than the telemonitoring communication. Trial registration ISRCTN96634935. Funding: The trial was funded by an NHS applied research programme grant from the Chief Scientist Office of the Scottish government (ARPG/07/03). The funder had no role in study design and the collection, analysis, and interpretation of data and the writing of the article and the decision to submit it for publication. NHS Lothian supported the telemonitoring service and the clinical services.

24 May 2013 in BMJ
Verified
Journal Article
Open access
PDF file
BMBrian McKinstry
Brian McKinstry
JHJanet Hanley
Janet Hanley
SWSarah Wild
Sarah Wild
CPClaudia Pagliari
Claudia Pagliari
MPMary Paterson
Mary Paterson
PPPaul Padfield
Paul Padfield
Objective To determine if an intervention consisting of telemonitoring and supervision by usual primary care clinicians of home self measured blood pressure and optional patient decision support leads to clinically important reductions in daytime systolic and diastolic ambulatory blood pressure in patients with uncontrolled blood pressure. Design Multicentre randomised controlled trial. Setting 20 primary care practices in south east Scotland. Participants 401 people aged 29-95 years with uncontrolled blood pressure (mean daytime ambulatory measurement ≥135/85 mm Hg but ≤210/135 mm Hg). Intervention Self measurement and transmission of blood pressure readings to a secure website for review by the attending nurse or doctor and participant, with optional automated patient decision support by text or email for six months. Main outcome measures Blinded assessment of mean daytime systolic ambulatory blood pressure six months after randomisation. Results 200 participants were randomised to the intervention and 201 to usual care; primary outcome data were available for 90% of participants (182 and 177, respectively). The mean difference in daytime systolic ambulatory blood pressure adjusted for baseline and minimisation factors between intervention and usual care was 4.3 mm Hg (95% confidence interval 2.0 to 6.5; P=0.0002) and for daytime diastolic ambulatory blood pressure was 2.3 mm Hg (0.9 to 3.6; P=0.001), with higher values in the usual care group. The intervention was associated with a mean increase of one general practitioner (95% confidence interval 0.5 to 1.6; P=0.0002) and 0.6 (0.1 to 1.0; P=0.01) practice nurse consultations during the course of the study. Conclusions Supported self monitoring by telemonitoring is an effective method for achieving clinically important reductions in blood pressure in patients with uncontrolled hypertension in primary care settings. However, it was associated with increase in use of National Health Service resources. Further research is required to determine if the reduction in blood pressure is maintained in the longer term and if the intervention is cost effective. Trial registration Current Controlled Trials ISRCTN72614272.

4 March 2013 in Journal of Clinical Nursing
Verified
Journal Article
Closed access
PDF file
PFPeter Fairbrother
Peter Fairbrother
JUJenny Ure
Jenny Ure
JHJanet Hanley
Janet Hanley
LMLucy McCloughan
Lucy McCloughan
MDMartin Denvir
Martin Denvir
TTThe Telescot programme team
The Telescot programme team

1 August 2019 in Health Technology Assessment
Verified
Journal Article
Closed access
AMAlasdair MJ MacLullich
Alasdair MJ MacLullich
Susan ShenkinSusan Shenkin
Susan Shenkin
SGSteve Goodacre
Steve Goodacre
MGMary Godfrey
Mary Godfrey
JHJanet Hanley
Janet Hanley
AGAlasdair Gray
Alasdair Gray
Background: Delirium is a common and serious neuropsychiatric syndrome, usually triggered by illness or drugs. It remains underdetected. One reason for this is a lack of brief, pragmatic assessment tools. The 4 ‘A’s test (Arousal, Attention, Abbreviated Mental Test – 4, Acute change) (4AT) is a screening tool designed for routine use. This project evaluated its usability, diagnostic accuracy and cost.Methods: Phase 1 – the usability of the 4AT in routine practice was measured with two surveys and two qualitative studies of health-care professionals, and a review of current clinical use of the 4AT as well as its presence in guidelines and reports. Phase 2 – the 4AT’s diagnostic accuracy was assessed in newly admitted acute medical patients aged ≥ 70 years. Its performance was compared with that of the Confusion Assessment Method (CAM; a longer screening tool). The performance of individual 4AT test items was related to cognitive status, length of stay, new institutionalisation, mortality at 12 weeks and outcomes. The method used was a prospective, double-blind diagnostic test accuracy study in emergency departments or in acute general medical wards in three UK sites. Each patient underwent a reference standard delirium assessment and was also randomised to receive an assessment with either the 4AT (n = 421) or the CAM (n = 420). A health economics analysis was also conducted.Results: Phase 1 found evidence that delirium awareness is increasing, but also that there is a need for education on delirium in general and on the 4AT in particular. Most users reported that the 4AT was useful, and it was in widespread use both in the UK and beyond. No changes to the 4AT were considered necessary. Phase 2 involved 785 individuals who had data for analysis; their mean age was 81.4 (standard deviation 6.4) years, 45% were male, 99% were white and 9% had a known dementia diagnosis. The 4AT (n = 392) had an area under the receiver operating characteristic curve of 0.90. A positive 4AT score (> 3) had a specificity of 95% [95% confidence interval (CI) 92% to 97%] and a sensitivity of 76% (95% CI 61% to 87%) for reference standard delirium. The CAM (n = 382) had a specificity of 100% (95% CI 98% to 100%) and a sensitivity of 40% (95% CI 26% to 57%) in the subset of participants whom it was possible to assess using this. Patients with positive 4AT scores had longer lengths of stay (median 5 days, interquartile range 2.0–14.0 days) than did those with negative 4AT scores (median 2 days, interquartile range 1.0–6.0 days), and they had a higher 12-week mortality rate (16.1% and 9.2%, respectively). The estimated 12-week costs of an initial inpatient stay for patients with delirium were more than double the costs of an inpatient stay for patients without delirium (e.g. in Scotland, £7559, 95% CI £7362 to £7755, vs. £4215, 95% CI £4175 to £4254). The estimated cost of false-positive cases was £4653, of false-negative cases was £8956, and of a missed diagnosis was £2067.Limitations: Patients were aged ≥ 70 years and were assessed soon after they were admitted, limiting generalisability. The treatment of patients in accordance with reference standard diagnosis limited the ability to assess comparative cost-effectiveness.Conclusions: These findings support the use of the 4AT as a rapid delirium assessment instrument. The 4AT has acceptable diagnostic accuracy for acute older patients aged > 70 years.Future work: Further research should address the real-world implementation of delirium assessment. The 4AT should be tested in other populations.Trial registration: Current Controlled Trials ISRCTN53388093.Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full inHealth Technology Assessment; Vol. 23, No. 40. See the NIHR Journals Library website for further project information. The funder specified that any new delirium assessment tool should be compared against the CAM, but had no other role in the study design or conduct of the study.

14 December 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RPRichard A Parker
Richard A Parker
CWChristopher J Weir
Christopher J Weir
NRNoah Rubio
Noah Rubio
RRRoberto Rabinovich
Roberto Rabinovich
HPHilary Pinnock
Hilary Pinnock
BMBrian McKinstry
Brian McKinstry
The Bland-Altman limits of agreement method is widely used to assess how well the measurements produced by two raters, devices or systems agree with each other. However, mixed effects versions of the method which take into account multiple sources of variability are less well described in the literature. We address the practical challenges of applying mixed effects limits of agreement to the comparison of several devices to measure respiratory rate in patients with chronic obstructive pulmonary disease (COPD). Respiratory rate was measured in 21 people with a range of severity of COPD. Participants were asked to perform eleven different activities representative of daily life during a laboratory-based standardised protocol of 57 minutes. A mixed effects limits of agreement method was used to assess the agreement of five commercially available monitors (Camera, Photoplethysmography (PPG), Impedance, Accelerometer, and Chest-band) with the current gold standard device for measuring respiratory rate. Results produced using mixed effects limits of agreement were compared to results from a fixed effects method based on analysis of variance (ANOVA) and were found to be similar. The Accelerometer and Chest-band devices produced the narrowest limits of agreement (-8.63 to 4.27 and -9.99 to 6.80 respectively) with mean bias -2.18 and -1.60 breaths per minute. These devices also had the lowest within-participant and overall standard deviations (3.23 and 3.29 for Accelerometer and 4.17 and 4.28 for Chest-band respectively). The mixed effects limits of agreement analysis enabled us to answer the question of which devices showed the strongest agreement with the gold standard device with respect to measuring respiratory rates. In particular, the estimated within-participant and overall standard deviations of the differences, which are easily obtainable from the mixed effects model results, gave a clear indication that the Accelerometer and Chest-band devices performed best.

5 May 2001 in BMJ
Verified
Journal Article
Closed access
PDF file
JHJanet Hanley
Janet Hanley
ACAnn Capewell
Ann Capewell
Suzanne HagenSuzanne Hagen
Suzanne Hagen
The severity index comprises the following two questions. How often do you experience urine leakage (0=never, 1=less than once a month, 2=one or several times a month, 3=one or several times a week, 4=every day and/or night)? How much urine do you lose each time (1=drops or little, 2=more)? The total score is the score for the first question multiplied by the score for the second question (0=dry, 1-2=slight, 3-4=moderate, 6-8=severe). We added the category “dry” for women whose urinary incontinence was cured. A version of the index splitting the “severe” category into severe and very severe has recently been published.3