Serkan Doganay

Serkan Doganay

Auto-generated profile, based on publicly available information

Serkan Doganay

Mechatronics Engineering Department, İzmir Kâtip Çelebi University, 35620 Cigli, Izmir, Turkey

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
HKHalil Dogacan Koca
Halil Dogacan Koca
SDSerkan Doganay
Serkan Doganay
ATAlpaslan Turgut
Alpaslan Turgut
ITIsmail Hakki Tavman
Ismail Hakki Tavman
SRSaidur Rahman
Saidur Rahman
IMIslam Mohammed Mahbubul
Islam Mohammed Mahbubul

1 September 2019 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
SDSerkan Doganay
Serkan Doganay
RARahime Alsangur
Rahime Alsangur
ATAlpaslan Turgut
Alpaslan Turgut

1 March 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
HKHalil Dogacan Koca
Halil Dogacan Koca
SDSerkan Doganay
Serkan Doganay
ATAlpaslan Turgut
Alpaslan Turgut

1 March 2019 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
SDSerkan Doganay
Serkan Doganay
ATAlpaslan Turgut
Alpaslan Turgut
LCLevent Cetin
Levent Cetin

1 January 2015 in Applied Thermal Engineering
Verified
Journal Article
Closed access
SDSerkan Doganay
Serkan Doganay
ATAlpaslan Turgut
Alpaslan Turgut

25 May 2020 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
SDSerkan Doganay
Serkan Doganay
LCLevent Cetin
Levent Cetin
MEMehmet Akif Ezan
Mehmet Akif Ezan
ATAlpaslan Turgut
Alpaslan Turgut
In this study, a novel rotating permanent magnetic actuator (PMA) system is proposed to manipulate magnetic nanofluids to pump chemicals inside micro-sized channels with circular paths. The PMA consists of two permanent magnet pairs and a rotor-like structure. A semicircular-shaped microchannel with a square cross-section area is located at the top of the actuator in order to investigate the performance of the PMA. Fe 3 O 4 -water magnetic nanofluid is employed as a working fluid for the manipulation inside the microchannel. In the first stage of this work, a numerical survey is conducted to determine the most suitable angular distance between permanent magnets of a pair in terms of generated magnetic field form in the microchannel region and velocity distribution of magnetic nanofluid within the semicircular microchannel when the permanent magnets are stationary. Preliminary experiments are then carried out for the stationary permanent magnets to validate the predicted flow-field results. Performance tests for different PMA speeds (7.5–30 rpm) and particle concentrations (1%–3% by vol.) indicate that it is possible to manipulate the magnetic nanofluid inside the semicircular channel within a velocity range of 58.7–940 µ m s −1 , which corresponds to a flow rate range of 0.56–9.02 µ L min −1 . The results confirm that the proposed PMA system provides flow rate requirements in analytical microfluidic applications such as low flow drug delivery (1–10 µ L min −1 ), cell sorting (6.1 µ L min −1 ), and pathogen detection (3–5.83 µ L min −1 ).