The aim of this paper is to present the interest of implementing digital controllers using field-programmable gate array (FPGA) components. To this purpose, a variety of current control techniques, which is applied to alternating current machine drives, is designed and implemented. They consist of on-off current controllers, proportional-integral current controller, and predictive current controller. The quality of the regulated current is significantly improved. It is mainly due to a very important reduction of the execution time delay. Indeed, in all described techniques, the execution time of the designed hardware architectures is only a few microseconds. This time reduction derives directly from the possibility offered by FPGAs to design very powerful dedicated architectures. Numerous experimental results are given in order to illustrate the efficiency of FPGA-based solutions to achieve high-performance control of electrical systems.
7 April 2011 in IEEE Transactions on Power Electronics
This paper focuses on sensor fault detection and isolation (FDI) for electrical systems. A new, easy and fast FDI algorithm is proposed, keeping system performances unchanged under certain faulty sensor conditions when reconfigurations are available. The proposed FDI algorithm is derived from a parity space approach and is based on temporal redundancies. It is insensitive to parameter variations since no model knowledge is required. Also, it is available for a large class of electrical systems such as single- or three-phase power converters, dc or ac electrical drives, etc. Moreover, the residual threshold used for FDI is accurately defined and is suitable for the whole operating range. Simulations results are presented to illustrate the good functionality of theoretical developments. Numerous experimental results are also shown to validate the effectiveness of the proposed FDI algorithm and to highlight its advantages for the control of electrical systems.
16 May 2013 in IEEE Transactions on Power Electronics
This paper presents an easy and a robust sensor fault detection and isolation (FDI) and fault tolerant control (FTC) of a single phase PWM rectifier for electrical railway traction application. Catenary current sensor and dc link voltage sensor failures are considered. The FDI method is based on observers and residual generation. The different FDI algorithm steps allow a good detection and isolation of the sensor fault and identify the faulty sensor. The reconfiguration strategy consists of two steps with open loop control and closed loop control working. Simulation results are presented to illustrate the good performance of the FTC procedure. Experimental results are also presented to show the effectiveness of the proposed FDI and FTC algorithms and good performances of the rectifier after the reconfiguration.
8 November 2016 in IEEE Transactions on Power Electronics
Grid-connected converters (GcCs) employ LCL filters instead of simple L filters in order to meet new grid codes and their on-going changes in the near future. Active damping methods, without power losses, are preferred to passive ones for solving the resonance problems of LCL-filter-based GcCs ( LCL-GcCs). However, large changes in the grid inductance (typically under weak grid conditions and in rural areas) may compromise the system stability. Moreover, the delay of digital controllers will change system phase-frequency characteristics and consequently will affect the system stability. In view of this, this paper proposes a systematic design procedure for the active damping of voltage-oriented PI control for LCL- GcCs. The procedure considers active damping methods based on capacitor current feedback and is aimed to ensure stable operation under severe grid inductance variations while taking into account the influence of digital control delay and LCL filter parameters changes on the system stability. Simulation and experimental results are presented and discussed in order to validate the proposed design procedure.
28 April 2009 in IEEE Transactions on Industrial Electronics
This paper presents a grid-connection control strategy of doubly fed induction generator wind system based on the direct control of both a virtual torque and rotor flux of the generator. This control is achieved with no proportional-integral regulator and requires the measurement of only grid voltages, rotor currents, and rotor position. The same switching table is used for grid synchronization and for running process. A field-programmable-gate-array-based design of the proposed control is developed and tested on a 4-kW experimental prototype. Experimental results are provided to show the effectiveness of the fast and soft grid-connection method developed.