16 June 2021 in IEEE Transactions on Industrial Electronics
In this article, we analyze the negative impact of phase-locked loop (PLL) on the stability of the doubly fed induction generators system. The small-signal disturbance of PLL mainly affects the coordinate transformation of the rotor current and introduces a negative resistance within PLL bandwidth. Two impedance reshaping methods are carried out to weaken this negative resistance. A virtual impedance in the conventional current control is added to the first reshaping method. The second reshaping method completely removes the coordinate transformation of the rotor current by switching the control target from current to power. The difference between these two reshaping methods is analyzed based on the equivalent single-input single-output impedance model. The experimental results validate the effectiveness of these two reshaping methods and the superiority of the second reshaping method at a lower short-circuit ratio.
11 June 2024 in IEEE Transactions on Industrial Electronics
Due to the limited overcurrent capability of semiconductor components, the grid-forming (GFM) inverters require additional overcurrent protection schemes. This article analyzes the interaction between the circular current limiter and different types of virtual impedance from the perspective of transient stability. The established unified equivalent circuit model reveals the mechanism of current limitation by the circular limiter, which is based on both the feedforward-virtual impedance (FVI) method and embedded-virtual impedance (EVI) method. Although with the same current-limiting effects, the power-angle characteristics of these two methods are different. The dominant factor influencing transient stability is demonstrated by the analysis of power-angle trajectory. This study observes that the EVI method exhibits superior transient stability compared to the FVI method under the same parameters. Further, a parameter-switching approach based on the EVI method is proposed, which aims to achieve an extended fault ride-through duration. Finally, theoretical analysis is validated through simulations and control hardware-in-the-loop experiments.
15 February 2022 in IEEE Transactions on Industrial Electronics
The phase-locked loop (PLL) will have a negative impact on the stability of doubly fed induction generators (DFIG) system under inductive weak grid. Some PLL-less methods have been presented to remove the PLL such as switching the synchronous reference frame to the virtual reference frame or αβ -frame. Based on the equivalent single-input single-output impedance model, it is found that the DFIG systems implemented in the virtual reference frame or αβ -frame are more stable than synchronous reference frame. The reason is that the stator voltage will disturb the reference current calculation of the virtual reference frame and αβ -frame, then introduce a reference calculation matrix G cal . This matrix will keep the phase of DFIG system always −90° around fundamental frequency, then narrow the negative resistance band and enhance the phase margin (PM). In order to further illustrate the stability improvement caused by G cal , this article proposes a stability improvement method by emulating the G cal in synchronous reference frame, so as to improve the PM while retaining the advantages of PLL under unbalanced or harmonically distorted voltage, and fault ride through. The experimental results validate the aforementioned conclusions.
6 May 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Impedance measurement is an effective method to obtain the impedance characteristic of renewable power generation equipment (RPGE) for stability analysis. Frequency-coupling characteristic of RPGE will bring about the difficulty to measuring the impedance in a wide frequency band based on broadband signals. In order to guarantee the accuracy of the broadband impedance measurement considering the frequency–coupling characteristic, this article explores the method to accurately measure the frequency–coupling characteristic of the RPGE. The signal-to-noise ratio (SNR) issue in view of the measurement of the frequency–coupling characteristic is also investigated. Accordingly, an evaluation method for measurement accuracy is proposed. The evaluation results will be adopted to guide the design for the perturbation amplitudes. The redesigned multi-sine signal will be used in another group of measurements so as to achieve a targeted accuracy level. Finally, experiments based on the Typhoon control-hardware-in-loop (CHIL) platform are carried out to verify the reliability of the proposed evaluation method and the effectiveness of the proposed design method for the perturbation amplitudes.
18 December 2020 in IEEE Transactions on Power Electronics
Direct power control (DPC) can reduce the complexity of a controller and enhance the dynamic response for doubly fed induction generators (DFIG) system. The high-frequency resonance (HFR) issues will be analyzed for the DFIG system based on DPC under inductive weak grid in this article. Based on the simplified high-frequency impedance model of the DFIG system based on DPC and the Bode diagram of equivalent single-input single-output impedance, it is found that a strong frequency coupling related to the components of system delay in off-diagonal admittance will cause the high-frequency phase to change periodically for the DFIG system. Therefore, the DFIG system will show capacitive or even negative resistance to introduce potential risk of HFR at high frequency. The stability of a DFIG system will be further deteriorated as the system delay increases. An impedance reshaping control strategy is proposed to reduce the degree of frequency coupling at high frequency for eliminating the negative effects of system delay, so that HFR can be suppressed. The experimental results validate the availability of the proposed reshaping control strategy.
18 January 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
With the increasing penetration of renewable energy, it is important to analyze the impedance characteristic of renewable energy grid-connected system (REGS) to implement the stability analysis of the grid connection operation. In order to further improve the accuracy of the broadband impedance measurement, this article proposes a design method for the multisine signal considering both the signal-to-noise ratios (SNRs) of the perturbation signal and the response signal in the impedance measurement. By quantitatively analyzing the mathematical relationship between the SNRs and the measurement error, the principle to select the minimum SNR requirement of the perturbation and response signal can be obtained so as to guide the amplitude design of the perturbation signal, which can further improve the broadband impedance measurement accuracy. The multisine signal is adopted in this article to realize the proposed design method. In the application of the multisine signal, in order to limit the peak value of the multisine signal to avoid overmodulation, an improved phase design method for the multisine signal based on crest factor reduction algorithm is proposed. Finally, experiments based on the Typhoon control-hardware-in-loop (CHIL) platform are carried out to verify the effectiveness of the proposed design method for the multisine signal in the impedance measurement.