Gordana Stanković-Babić

Gordana Stanković-Babić

Auto-generated profile, based on publicly available information

Gordana Stanković-Babić

Clinical Center, Clinic for Eye Diseases, Niš + Faculty of Medicine, Niš

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Vojnosanitetski Pregled
Verified
Journal Article
Open access
PDF file
JDJasmina Djordjevic-Jocic¹
Jasmina Djordjevic-Jocic¹
GZGordana Zlatanovic
Gordana Zlatanovic
DVDragan Veselinovic
Dragan Veselinovic
PJPredrag Jovanovic
Predrag Jovanovic
VDVidosava Djordjevic
Vidosava Djordjevic
USUrsula Schlotzer-Schrehardt
Ursula Schlotzer-Schrehardt
Background/Aim. Transforming growth factor-b1 (TGF-b1), oxidative stress and imbalance between matrix metalloproteinases (MMPs) and their tissue inhibitors (TIMPs) may play an important role in pathogenesis of pseudoexfoliation syndrome/glaucoma (PEX Sy/Gl). The aim of the study was to measure concentrations of TGF- b1, MMP-2, TIMP-2 in the aqueous humor in the examined group, as well as to compare the biochemical findings with the following clinical parameters: degree of chamber angle pigmantation, presence of pseudoexfoliation and the value of intraocular pressure (IOP). Methods. Aqueous samples from 30 patients with cataract, 30 patients with PEX Sy, 36 patients with PEX Gl, and 42 patients with primary open-angle glaucoma (POAG) were collected during phacoemulsification cataract surgery. TGF b1, MMP-2, TIMP-2 Fluotokine Multi Analyze Profiling kits and Luminex technology were used to simultaneously measure TGF b1, MMP-2 and TIMP-2. Results. TGF- ?1, MMP-2, TIMP-2 were detected in human aqueous from all the groups with the highest level in the group with PEX Gl. Statistically, a significant correlation between the levels of TGF b1, MMP-2, TIMP-2 in the aqueous humor of the patients with PEX Gl and the IOP value was confirmed (p < 0.05). In this group, the positive correlations between the TGF b1 concentration in the aqueous humor and the presence of pseudoexfoliation (p < 0.01), on the one hand, and between the TIMP-2 level and the presence of pseudoexfoliation (p < 0.05), on the other, were reported. A statistically significant positive correlation of TGF-b1 and MMP-2, and the degree of chamber angle pigmentation in the PEX Gl group was confirmed (p < 0.05). In the POAG group, TIMP-2 values were in a negative correlation with the degree of pigmentation (p < 0.05), and the IOP value (p < 0.05). Conclusion. TGF b1 and MMP-2 affect the degree of chamber angle pigmentation and the degree of pseudoexfoliation in patients with pseudoexfoliative glaucoma.

7 September 2017 in Ophthalmic Research
Verified
Journal Article
Closed access
MZMaja Zivkovic
Maja Zivkovic
VDVolkan Dayanir
Volkan Dayanir
MZMarko Zlatanovic
Marko Zlatanovic
GZGordana Zlatanovic
Gordana Zlatanovic
VJVesna Jaksic
Vesna Jaksic
SJSvetlana Jovanovic
Svetlana Jovanovic
Aim: To compare ganglion cell (GCL) and inner plexiform layer (IPL) thickness in patients at different stages of primary open-angle glaucoma (POAG), determine their sensitivity and specificity values, and correlate thickness values with mean deviations (MD). Methods: This prospective, cross- sectional study was conducted in a group of patients with confirmed POAG who were compared to an age- and gender-matched control group. Glaucomatous damage was classified according to the Hodapp-Parrish-Anderson scale: glaucoma stage 1 (early), glaucoma stage 2 (moderate), and glaucoma stage 3 (severe). The average, minimum, and all 6 sectoral (superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal) GCL + IPL thicknesses were measured and compared between groups. Results: The average GCL + IPL thickness of 154 eyes of 93 patients in glaucoma stages 1, 2, 3, and 94 eyes of 47 persons in the control group were 76.79 ± 8.05, 65.90 ± 7.92, 57.38 ± 10.00, and 86.01 ± 3.68 μm, respectively. There were statistically significant differences in the average, minimum, and all 6 sectoral GCL + IPL values among the groups. The areas under the receiver operating characteristic curve for average and minimum GCL + IPL thickness values were 0.93 and 0.94, respectively, sensitivity 91.5 and 88.3%, and specificity 98.9 and 100%, respectively. Both thickness values showed significant correlations with MD. Each micrometer decrease in the average GCL + IPL thickness was associated with a 0.54-dB loss in MD. Conclusion: GCL + IPL layer thickness is a highly specific and sensitive parameter in differentiating glaucomatous from healthy eyes showing progressive damage as glaucoma worsens. Loss of this layer is highly correlated with overall loss of visual field sensitivity.

1 January 2016 in Medicinski Pregled
Verified
Journal Article
Open access
PDF file
RBRade R. Babić
Rade R. Babić
SBStanković Gordana Babić
Stanković Gordana Babić
SBStrahinja R. Babić
Strahinja R. Babić
NBNevena R. Babić
Nevena R. Babić
This paper is intended to celebrate the 120th anniversary of the discovery of X-rays. X-rays (Roentgen-rays) were discovered on the 8th of November, 1895 by the German physicist Wilhelm Conrad Roentgen. Fifty days after the discovery of X-ray, on December 28, 1895, Wilhelm Conrad Roentgen published a paper about the discovery of X-rays - ?On a new kind of rays? (Wilhelm Conrad Roentgen: ?ber eine neue Art von Strahlen. In: Sitzungsberichte der W?rzburger Physik.-Medic.-Gesellschaft. 1895.). Therefore, the date of 28th of December, 1895 was taken as the date of X-rays discovery. This paper describes the work of Wilhelm Conrad Roentgen, Nikola Tesla, Mihajlo Pupin and Maria Sklodowska-Curie about the nature of X-rays. The fantastic four - Wilhelm Conrad Roentgen, Nikola Tesla, Mihajlo Idvorski Pupin and Maria Sklodowska-Curie set the foundation of radiology with their discovery and study of X-rays. Five years after the discovery of X-rays, in 1900, Dr Avram Vinaver had the first X-ray machine installed in Sabac, in Serbia at the time when many developed countries did not have an X-ray machine and thus set the foundation of radiology in Serbia.

20 May 2010 in Bosnian Journal of Basic Medical Sciences
Verified
Journal Article
Closed access
PDF file
SCSonja Cekić
Sonja Cekić
GSGordana Stanković-Babić
Gordana Stanković-Babić
ZVZlatica Višnjić
Zlatica Višnjić
IJIvan Jovanovic
Ivan Jovanovic
DRDijana Risimic
Dijana Risimic
Congenital abnormalities of the optic disc are not so rare. The etiology for the most of them is unknown. Visual acuity of affected eye may be minimally or severely affected, depending on the extent of lesion. All of these conditions can be unilateral or bilateral. Chíldren who have unilateral optic disc abnormalities generally present during the preschool years with sensory esotropia. Visual acuity may be unaffected like in optic disc pit, optic disc drusen, fibre medullares, ect. However, during the evolution they may cause a decrease in visual acuity like serous retinal detachment in optic disc pit, atrophy or subretinal neovascularisation in optic disc drusen. Some of them like fibre medullares needs only a good diagnose and they do not have any evolution. Fluorescein angiography and ultrasonography may be crucial diagnostic procedures to discover some of them, like optic disc drusen. Optic disc abnormalities may be associated with other congenital disorders of the eye and often central nervous system malformations. Secondary they may be associated retinal detachment, retinochisis, macular edema, choroid neovascularisation and lipid exudation. Some of these conditions may be found on routine ophthalmologic exam such as optic disc drusen and fibre medullares and often are diagnostically problem.The aim of our study was to present some of our cases with different optic disc abnormalities such as fibre medullares, optic disc coloboma, hypoplasio disci, optic disc drusen and optic disc pit.

1 January 2011 in Srpski arhiv za celokupno lekarstvo
Verified
Journal Article
Open access
PDF file
GSGordana Stankovic-Babic
Gordana Stankovic-Babic
MVMilena Vujanovic
Milena Vujanovic
SCSonja Cekić
Sonja Cekić
Introduction. Identical twins account for 0.2% of the world population and 8% of all twins. A ?mirror image? variation can be found in 25% of identical twins. Studies of twins assume a special place in human genetics due to the possibility of comparing genetic and other factors. We present two pairs of identical male twins with mirror-image astigmatism and esotropia. Case Outline. The first was a pair of twelve-year old identical twins with ?mirror image? myopic astigmatism. The Twin 1 had myopic astigmatism in the right eye, while the Twin 2 was affected by the left eye myopic astigmatism. The second was a pair of six-year old identical twins with esotropia and hypermetropic astigmatism. The Twin 1 had esotropia in the left eye, while the right eye was affected in the Twin 2. Esotropia was surgically corrected. Conclusion. In this study we pointed to the role of genetic factors in the development of refractive error, as well as the type of strabismus. Refraction anomalies (myopia, hypermetropia and astigmatism) are complex heterogeneous disorders and ideal for genetic investigation. The knowledge of genetic mechanisms involved in refractive error susceptibility may allow treatment to prevent progression or to further examine gene-environment interactions. We hope that this paper will initiate further investigation of refraction anomalies in twins and future multicentre studies, which, to our knowledge, have not been conducted in our country so far.

20 August 2014 in Biomolecules and Biomedicine
Verified
Journal Article
Open access
PDF file
SCSonja Cekić
Sonja Cekić
TCTatjana Cvetkovic
Tatjana Cvetkovic
IJIvan Jovanovic
Ivan Jovanovic
PJPredrag Jovanovic
Predrag Jovanovic
MPMilica Pesic
Milica Pesic
DRDijana Risimic
Dijana Risimic
The aim of the study was to investegate the correlation between the levels of CRP and YKL-40 in blood samples with morphometric parameters of retinal blood vessels in patients with diabetic retinopathy. Blood laboratory examination of 90 patients included the measurement of glycemia, HbA1C, total cholesterol, LDL-C, HDL-C, triglycerides and CRP. Levels of YKL-40 were detected and measured in serum by ELISA (Micro VueYKL-40 EIA Kit, Quidel Corporation, San Diego, USA). Morphmetric analysis was performed with ImageJ software (http://rsbweb.nih.gov/ij/) for digital retinal photography. We measured the number, diameter of retinal blood vessels in five different parts concentric to the optic disc. Differences between the morphometric parameters and the blood test analysis results were evaluated using the Student’s t – test. One Way ANOVA was used to establish the significance of differences. CRP and YKL-40 levels were moderately higher in the group of patients with severe diabetic retinopathy. Levels of YKL-40 correlated positively with diameter and negatively with number of retinal blood vessels. The average number of the blood vessels per retinal zone was significantly higher in the group of patients with mild non-proliferative diabetic retinopathy than in the group with severe form in the optic disc and all five retinal zones. The average outer diameter of the evaluated retinal zones and optic disc vessels was significantly higher in the group with severe compared to the group with mild diabetic retinopathy. Morphological analysis of the retinal vessels on digital fundus photography and correlation with YKL-40 may be valuable for the follow-up of diabetic retinopathy.