11 March 2021 in IEEE Transactions on Instrumentation and Measurement
Haptics plays an important role in grasping and manipulating objects for human hands and artificial robotic hands. The density of tactile receptors at the tips of the fingers is very high, reaching 140 units/cm 2 . However, the density of the existing tactile sensors is very low. To increase the density of the 3-D tactile sensor, a novel high-density arrayed and curved 3-D tactile sensor based on bionic compound eye with the density up to 42 units/cm 2 is proposed in this article. The tactile sensor can detect both normal force and shear force since it is isotropic. The force measurement setup has been successfully built with a sensitivity of 0.000280 mN/Gray for normal force and 0.0262 N/ μm for shear force. The sensor will provide a technical basis for force measurement of surgical robots and manipulators.
23 February 2026 in IEEE Transactions on Instrumentation and Measurement
Tactile sensing is a foundational technology for advancing artificial intelligence and flexible electronics. Magnetically based tactile sensors show considerable promise; however, prior research has predominantly focused on magnetic films, overlooking the optimization of the non-magnetic elastic layer. This study introduces a complementary design strategy that enhances performance through geometric optimization of the non-magnetic elastic layer. A flexible magnetic tactile sensor (FMTS) with a sandwich architecture is presented, and a systematic quantitative analysis is conducted to show how elastic-layer geometry affects sensitivity and measurement range. A clear geometry-performance relationship is established by comparing planar, hemispherical, and directionally anisotropic pyramidal microstructures and integrating magnetic field modeling with mechanical analysis. Relative to the planar baseline, hemispherical and pyramidal microstructures improve normal-force sensitivity by factors of 2.47 and 5.34, and shear-force sensitivity by factors of 2.12 and 4.28, respectively, while the normal-force measurement range can be tuned from 1700 gf (planar) down to 380 gf (pyramidal). The FMTS achieves triaxial decoupling with quantified crosstalk, exhibits long-term stability (as validated by stress-relaxation and creep tests) and environmental robustness (under thermal and humidity tests), and demonstrates practical utility in grip-force monitoring. In summary, this work establishes a new design dimension for high-performance flexible magnetic sensors by tailoring elastic microstructures—an approach conceptually distinct from, yet functionally complementary to, prevailing magnetization strategies.
11 November 2026 in IEEE Robotics and Automation Letters