12 December 2018 in Biomedical Engineering / Biomedizinische Technik
Safety-relevant gait situations (walking on stairs and slopes, walking backwards, walking with small steps, simulated perturbations of swing phase extension) were investigated in a motion analysis laboratory with six unilateral transfemoral amputees using two different microprocessor-controlled prosthetic knee joints (Rheo Knee XC, C-Leg). A randomized crossover design was chosen. The study results imply that the performance and safety potential of a microprocessor-controlled knee joint can be associated with the individual control algorithms and the technological concepts that are implemented to generate motion resistances for controlling flexion and extension movements. When walking with small steps, advantages of the “default swing” concept used in the Rheo Knee XC were identified due to a highly reproducible swing phase release. However, when walking backwards, this concept may lead to an uncontrolled knee flexion which partly resulted in falls. When walking down stairs, walking on slopes or while recovering from a stumble after perturbations of the swing phase extension, the C-Leg demonstrated a reliable prosthetic side load-bearing capacity resulting in reduced loading on the residual body. In contrast, the Rheo Knee XC required increased compensatory movements of the remaining locomotor system in order to compensate for reduced load-bearing and safety reserves.
1 September 2021 in Gait & Posture
It is common practice to align transfemoral prosthetic sockets in adduction, due to the physiologic, adducted femoral alignment in unimpaired legs. An adducted femoral and socket alignment helps tightening hip abductors to stabilize the pelvis and reduce pelvic and trunk related compensatory movements. How do different socket adduction conditions (SAC) of transfemoral sockets affect pelvic and trunk stabilization during level ground walking in the frontal plane? Seven persons with transfemoral amputation with medium residual limb length participated in this study. The prosthetic alignment in the sagittal plane was performed according to established recommendations. SAC varied (0°, 3°, 6°, 9°). Kinematic and kinetic parameters were recorded in a gait laboratory with a 12-camera optoelectronic system and two piezoelectric force plates embedded in a 12-m walkway. The measurements were performed during level ground walking with self-selected comfortable gait speed. In the frontal plane, nearly all investigated kinematic and kinetic parameters showed a strong correlation with the SAC. The pelvis was raised on the contralateral side throughout the gait cycle with increasing SAC. During the prosthetic side stance phase, the mean shoulder obliquity and mean lateral trunk lean to the prosthetic side tended to be reduced with increased SAC. Prosthetic side hip abduction moment decreased with increasing SAC. The results confirm that transfemoral SAC contributes to pelvic stabilization and reduced compensatory movements of the pelvis and trunk. Transfemoral SAC of 6 ± 1° for bench alignment seems adequate for amputees with medium residual limb length. However, the optimum value for the individual patient may differ slightly.
16 May 2020 in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
BACKGROUND: An often assumed advantage of polycentric knee joints compared to monocentric ones is the improved ground clearance during swing phase due to the geometric shortening of the lower leg segment (LLS). OBJECTIVE: To investigate whether polycentric knee joints considerably improve ground clearance and to evaluate the influence of prosthetic alignment on the extent of ground clearance. METHODOLOGY: 11 polycentric and 2 monocentric knee joints were attached to a rigid, stationary testing device. Shortening of the LLS and the resulting ground clearance during knee flexion were measured. Prosthetic components were mounted at the same height and the anterior-posterior position was in accordance with the manufacturer's alignment recommendations. FINDINGS: Shortening of up to 14.7 (SD=0.0) mm at the instance of minimal ground clearance during swing phase was measured. One knee joint elongated by 4.4 (SD=0.0) mm. Measurements of the ground clearance demonstrated differences up to 25.4 (SD=0.0) mm. One monocentric knee joint provided more ground clearance when compared to 8 of the polycentric knee joints investigated. CONCLUSION: Only some polycentric knee joints shorten appreciably during swing phase. With an optimized prosthetic alignment and a well-designed swing phase control, a monocentric knee joint may generate greater ground clearance compared to a polycentric knee joint. LAYMAN’S ABSTRACT Tripping is a safety risk for amputees and it is mainly affected by ground clearance during swing phase. An often assumed advantage of polycentric knee joints compared to monocentric ones is the improved ground clearance during swing phase due to the geometric shortening of the lower leg segment (LLS). Based on this statement safety benefits for above knee-amputees due to reduced danger of stumbling are discussed commonly for the entire group of polycentric knee joints. We believe that this statement is not true for all polycentric knee joint designs. Therefore, we analyzed 11 polycentric and two monocentric knee joints in a rigid, stationary testing device with their individual prosthetic alignments according to the manufacturer’s alignment recommendations. Shortening of the LLS and the resulting ground clearance during knee flexion were measured. The results showed shortening effects of up to 15 mm. One knee joint elongated by 4 mm. One monocentric knee joint provided more ground clearance when compared to 8 of the polycentric knee joints investigated. We conclude, that only some polycentric knee joints shorten appreciably during swing phase. With an optimized prosthetic alignment a monocentric knee joint may generate greater ground clearance compared to a polycentric knee joint. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/33768/26547 How To Cite: Köhler T.M, Bellmann M, Blumentritt S. Polycentric Exoprosthetic Knee Joints – Extent of Shortening during Swing Phase. Canadian Prosthetics & Orthotics Journal. 2020;Volume3, Issue1, No.5. https://doi.org/10.33137/cpoj.v3i1.33768 Corresponding Author: Thomas Maximilian Köhler, MScOttobock: Hermann-Rein-Straße 2a, 37075, Göttingen.E-mail: thomasmaximilian.koehler@ottobock.deORCID: https://orcid.org/0000-0002-5063-121X
26 August 2025 in Gait & Posture
Prosthetic fittings for persons with a transfemoral amputation should provide adequate ground clearance (GC) during prosthetic side swing to minimize the risk of stumbling or falling. Insufficient ground clearance often leads to compensatory movements that consequently influence gait biomechanics negatively. How do different prosthetic components and alignment of a transfemoral prosthesis affect prosthetic side GC and compensatory strategies during level walking? Eight persons with transfemoral amputation were enrolled. Three different knee joints (one monocentric and two polycentric) as well as two prosthetic feet (with and without passive dorsiflexion) were investigated. For prosthetic alignment, ap-position of the knee and foot as well as prosthesis length were varied. Kinematic and kinetic parameters were recorded with a 12-camera optoelectronic system and two force plates embedded in a 12-m walkway. The measurements were performed during level walking with self-selected slow, mid and fast gait speed. Several consistent effects were observed. GC increased with higher prosthetic swing knee flexion angle, a more anterior knee position and more posterior foot position. The individual swing phase control of the investigated knee joints showed a higher impact on GC than by geometric shortening effects of the polycentric knee joints. Passive ankle dorsiflexion enhanced GC, but the more anterior position of the foot (recommended by the manufacturer) eliminates this effect. Shortening of the prosthesis did not affect GC consistently but resulted in negative impact on the pelvis and trunk. To compensate for a lack of GC, vaulting was primarily observed. The findings provide experts with a comprehensive overview of relevant factors influencing ground clearance. The importance of prosthetic alignment and prosthetic knee swing phase control was particularly evident. This can help to optimize the prosthetic fitting to the needs of the user and to reduce unnatural compensatory strategies.