Camilla Giaccaglia

Camilla Giaccaglia

Auto-generated profile, based on publicly available information

Camilla Giaccaglia

Laboratoire d'Optique Appliquée, ENSTA Paris, CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, 91120 Palaiseau, France - Institute Curie

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2023 in Physica Medica
Verified
Journal Article
Closed access
LFLuca Fardin
Luca Fardin
CGCamilla Giaccaglia
Camilla Giaccaglia
PBPaolo Busca
Paolo Busca
ABAlberto Bravin
Alberto Bravin

17 March 2025 in Physical Review Applied
Verified
Journal Article
Closed access
LML. Martelli
L. Martelli
OKO. Kononenko
O. Kononenko
IAI.A. Andriyash
I.A. Andriyash
JWJonathan A Wheeler
Jonathan A Wheeler
JGJulien Gautier
Julien Gautier
CTCedric Thaury
Cedric Thaury

28 May 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
CGCamilla Giaccaglia
Camilla Giaccaglia
EBEmilie Bayart
Emilie Bayart
MDMaxime Dubail
Maxime Dubail
CVChaitanya Varma
Chaitanya Varma
SHSophie Heinrich
Sophie Heinrich
LKLena Kononenko
Lena Kononenko
Purpose: This study systematically investigates the radiobiological effects of Very High Energy Electrons (VHEE) generated by a laser-plasma accelerator (LPA), in comparison with Conventional Intermediate Energy Electrons (CIEE) from a conventional linear accelerator (LINAC). Using in vitro, ex vivo , and in vivo models, we evaluate and compare their potential toxicity on healthy tissues. Methods and Materials: Cell survival, tissue response, and developmental toxicity were assessed across three biological models. In vitro , human fibroblasts (MRC5-hTERT) were used to generate post-irradiation survival curves. Ex vivo , precision-cut lung slices (PCLS) from mice were analyzed for radiation-induced inhibition of cell proliferation. In vivo , zebrafish embryos were used to evaluate developmental toxicity through body length and spinal curvature measurements. VHEE irradiations were performed using a broadband electron beam spanning 50–300 MeV, using the Salle Jaune LPA (Laboratoire d’Optique Appliquée, France), while CIEE exposures were performed with a 7 MeV conventional LINAC (Institut Curie, France). Results: In vitro , MRC5-hTERT cells showed no significant difference in radiosensitivity between VHEE and CIEE, with comparable D 10 values (p-value = 0.7). In the ex vivo model, both beams induced a dose-dependent decrease in cell division with no significant inter-beam differences at any dose level (p-value > 0.99). In vivo , zebrafish embryos exhibited dose-dependent body shortening and increased spinal curvature following both VHEE and CIEE exposure. No significant differences were observed between the two modalities at matched doses for any measured metric (p-value ≥ 0.5). Conclusion: This study presents the first comprehensive radiobiological evaluation of a laser-driven VHEE beam across multiple biological models. Under the investigated conditions, VHEE and CIEE irradiations exhibit similar biological toxicity. These findings support the feasibility and potential of VHEE generated with LPA for future clinical applications.

26 December 2025 in bioRxiv
Verified
Preprint
Open access
CGCamilla Giaccaglia
Camilla Giaccaglia
EBEmilie Bayart
Emilie Bayart
CVChaitanya Varma
Chaitanya Varma
JGJean-Philippe Goddet
Jean-Philippe Goddet
JGJulien Gautier
Julien Gautier
AFAlessandro Flacco
Alessandro Flacco
Radiotherapy (RT) is constrained by the narrow therapeutic window between tumour control and normal-tissue toxicity. While FLASH RT has been reported to reduce normal-tissue toxicity at ultra-high dose rates (UHDR) with preserved tumour control in several preclinical models, the radiobiological potential of temporal regimes intermediate between conventional fractionation and FLASH remains largely unexplored. Here, we use a laser-plasma accelerator (LPA) to access this regime by delivering sub-picosecond very high-energy electron (VHEE, 50–300 MeV) pulses at ultra-high instantaneous dose rates (UHIDR; > 10^9 Gy/s) with externally programmable inter-pulse intervals. We introduce Pulsed Fast Fractionation (PFF): ultrashort (fs-ps) pulses delivered under UHIDR conditions with second-scale inter-pulse intervals and implementation-dependent dose per pulse. In this work, we vary the inter-pulse interval from 1 to 10 s while keeping dose per pulse and total dose constant, and identify an interval of 1 s that enhances normal-tumour separation: human fibroblasts exhibit reduced toxicity, whereas colorectal carcinoma cells show increased cytotoxicity under matched dose conditions. In vivo, zebrafish embryos reproduce the interval-dependent normal-tissue protection, supporting relevance in a whole-organism context. These results establish second-scale pulse timing as a biologically active degree of freedom for VHEE delivery, positioning PFF as a temporally optimised approach that complements spatial dose modulation and extends the current fractionation-FLASH framework.

27 March 2026 in Advances in Radiation Oncology
Verified
Journal Article
Open access
CGCamilla Giaccaglia
Camilla Giaccaglia
EBEmilie Bayart
Emilie Bayart
MDMaxime Dubail
Maxime Dubail
CVChaitanya Varma
Chaitanya Varma
SHSophie Heinrich
Sophie Heinrich
AFAlessandro Flacco
Alessandro Flacco
This study systematically investigates the radiobiological effects of very high energy electrons (VHEE) generated by a laser-plasma accelerator (LPA), in comparison with conventional intermediate energy electrons (CIEE) from a conventional linear accelerator. Using in vitro, ex vivo, and in vivo models, we evaluate and compare their potential toxicity on healthy tissues. Cell viability, tissue response, and developmental toxicity were assessed across 3 biological models. In vitro, hTERT-immortalized, human fibroblasts (MRC5-hTERT) were used to generate postirradiation viability-based survival curves following a dose escalation of 2 to 10 Gy. Ex vivo, mouse precision-cut lung slices were analyzed for radiation-induced inhibition of cell replication after 3, 6, and 9 Gy. In vivo, zebrafish embryos were irradiated with 6 and 9 Gy and subsequently evaluated for developmental toxicity through body length and spinal curvature measurements. VHEE irradiations were delivered using the Salle Jaune LPA (Laboratoire d'Optique Appliquée), generating a broad-spectrum electron beam with a mean energy of 140.6 MeV at the biological target, while CIEE irradiations were performed using a conventional 7 MeV linear accelerator (Institut Curie). In vitro, MRC5-hTERT cells showed no significant difference in radiosensitivity between VHEE and CIEE conditions, with comparable D10 values (P value =.7). In the ex vivo model, both beams induced a dose-dependent decrease in cell division with no significant interbeam differences at any dose level (P value >.99). In vivo, zebrafish embryos exhibited dose-dependent body shortening and increased spinal curvature following both VHEE and CIEE exposure. No significant differences were observed between the 2 modalities at matched doses for any measured metric (P value ≥.5). To our knowledge, this study presents the first multiscale radiobiological evaluation of a laser-driven VHEE beam across cellular, tissue, and organismal levels. Under the investigated conditions, VHEE and CIEE irradiations produce similar biological toxicity. These findings support the feasibility and potential of VHEE generated by LPA for future clinical applications.