This paper presents a study of rubberized concretes designed by replacing coarse aggregate in normal concrete with ground and crushed scrap tire rubber in various volume ratios. The objective of the study was to investigate the effect of rubber types and rubber content on strength and deformation properties. The compressive strength, static, and dynamic modulus of elasticity of rubberized concrete were tested and studied. The stress-strain hysteresis loops were obtained by loading, unloading, and reloading on specimens. Brittleness index values were calculated based on the hysteretic loops. The experiments revealed that strength and modulus elasticity of rubberized concrete decreased with the increasing amount of rubber content. Compressive strength and modulus of elasticity of crushed rubberized concrete were lower than that of ground rubberized concrete. An American Concrete Institute equation could reasonably predict modulus of elasticity of rubberized concrete. Brittleness index values of rubberized concrete were lower than that of normal concrete, which means that rubberized concrete had higher ductility performance than that of normal concrete.
This paper presents a study of the skewness effect on live load reactions at the piers of continuous bridges. Two prestressed concrete I-beam bridges and one steel I-girder bridge were selected for the study. To evaluate the skew effect, the skew angle of the bridges was varied from 0 to 60° . Live load reaction at support and shear at the beam ends of the selected bridges were determined using finite-element analysis. The comparison of the distribution factors of live load reactions and shear revealed that the distribution factor of reaction at piers was higher than that of shear at beam ends near the same support. The increase in the reaction distribution factor was more significant than that in the shear distribution factor in the interior beam line when the skew angle was greater than 30° . The LRFD shear equations and the Lever rule method could conservatively predict live load reaction distribution for piers in exterior beam lines but underestimate live load reaction distribution in interior beam li...
Two slab-on-girder bridge superstructures are analyzed using grillage models. Different live load placement configurations are investigated to determine the sensitivity of live load shear and moment to vehicle spacing. Results from both bridges show that the distribution factors are relatively insensitive to vehicle spacing. Therefore significant computational speedups are available when applying vehicle loads on an influence surface with a fixed spacing.
Bridge load rating involves performing a series of calculations synonymous with bridge design calculations in order to determine if a bridge is safe for public traffic loads. The AASHTO Load Factor Rating (LFR) is the currently used method in bridge load rating. The Load and Resistance Factor Fating (LRFR) is a new guide manual adopted by the American Association of State Highway and Transportation Officials (AASHTO) in 2001 for condition evaluation of highway bridges. The guide manual reflects the most current technologies and builds on the structural reliability approach inherent in specifications for Load and Resistance Factor Design (LRFD). In this paper, seven prestressed concrete bridges of moderate span length (50 – 117 ft) are analyzed and rated using the AASHTO LFR and AASHTO LRFR methods. The selected bridges include one straight simple span Bulb Tee-girder, three skewed simple span I-girder, and three skewed continuous multi-span I-girder bridges. The comparison study for the prestressed concrete I-section bridges reveals some differences between the rating results using LFR and new LRFR methodologies. The majority of load ratings achieved using the LRFR approach for the prestressed concrete bridges are governed by shear rather than flexure, which is a substantial difference from the LFR method where flexural ratings typically govern for all bridge types.
This paper presents a study of skewness effect on live load reactions at piers of continuous prestressed concrete bridges. Two prestressed concrete bridges were selected for the study, one bridge with two-span and the other with four-span. To study the effect of skewness, the skew angles of the bridges were varied from 0° to 60°. Finite element modeling and analysis were performed on the selected bridges. The comparison for live load reaction and shear revealed that the distribution factor of reaction at piers was higher than that of shear at beam ends near the same support location. The increase in reaction distribution factor was more significant than that in shear distribution factor on the interior beam line when skew angle was greater than 30°. It is recommended that more research be performed for the distribution factor of live load reaction to quantify the responses.