Sabiniano Roman

Sabiniano Roman

Auto-generated profile, based on publicly available information

Sabiniano Roman

Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, Sheffield, United Kingdom

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Acta Biomaterialia
Verified
Journal Article
Open access
MFMartin Frydrych
Martin Frydrych
SRSabiniano Román
Sabiniano Román
SMSheila MacNeil
Sheila MacNeil
BCBiqiong Chen
Biqiong Chen
Large three-dimensional poly(glycerol sebacate) (PGS)/poly(l-lactic acid) (PLLA) scaffolds with similar bulk mechanical properties to native low and high stress adapted adipose tissue were fabricated via a freeze-drying and a subsequent curing process. PGS/PLLA scaffolds containing 73vol.% PGS were prepared using two different organic solvents, resulting in highly interconnected open-pore structures with porosities and pore sizes in the range of 91-92% and 109-141μm, respectively. Scanning electron microscopic analysis indicated that the scaffolds featured different microstructure characteristics, depending on the organic solvent in use. The PGS/PLLA scaffolds had a tensile Young's modulus of 0.030MPa, tensile strength of 0.007MPa, elongation at the maximum stress of 25% and full shape recovery capability upon release of the compressive load. In vitro degradation tests presented mass losses of 11-16% and 54-55% without and with the presence of lipase enzyme in 31days, respectively. In vitro cell tests exhibited clear evidence that the PGS/PLLA scaffolds prepared with 1,4-dioxane as the solvent are suitable for culture of adipose derived stem cells. Compared to pristine PLLA scaffolds prepared with the same procedure, these scaffolds provided favourable porous microstructures, good hydrophilic characteristics, and appropriate mechanical properties for soft tissue applications, as well as enhanced scaffold cell penetration and tissue in-growth characteristics. This work demonstrates that the PGS/PLLA scaffolds have potential for applications in adipose tissue engineering.

14 June 2013 in BJU International
Verified
Journal Article
Closed access
PDF file
AMAltaf Mangera
Altaf Mangera
ABAnthony James Bullock
Anthony James Bullock
SRSabiniano Roman
Sabiniano Roman
CCChristopher R. Chapple
Christopher R. Chapple
SMSheila MacNeil
Sheila MacNeil

19 July 2013 in Neurourology and Urodynamics
Verified
Journal Article
Closed access
PDF file
SRSabiniano Roman
Sabiniano Roman
AMAltaf Mangera
Altaf Mangera
NONadir I. Osman
Nadir I. Osman
ABAnthony James Bullock
Anthony James Bullock
CCChristopher R. Chapple
Christopher R. Chapple
SMSheila MacNeil
Sheila MacNeil

1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
GGGiulia Gigliobianco
Giulia Gigliobianco
SRSabiniano Roman Regueros
Sabiniano Roman Regueros
NONadir I. Osman
Nadir I. Osman
JBJulio Bissoli
Julio Bissoli
ABAnthony James Bullock
Anthony James Bullock
SMSheila Macneil
Sheila Macneil
Stress urinary incontinence (SUI) and pelvic organ prolapse (POP) are major health issues that detrimentally impact the quality of life of millions of women worldwide. Surgical repair is an effective and durable treatment for both conditions. Over the past two decades there has been a trend to enforce or reinforce repairs with synthetic and biological materials. The determinants of surgical outcome are many, encompassing the physical and mechanical properties of the material used, and individual immune responses, as well surgical and constitutional factors. Of the current biomaterials in use none represents an ideal. Biomaterials that induce limited inflammatory response followed by constructive remodelling appear to have more long term success than biomaterials that induce chronic inflammation, fibrosis and encapsulation. In this review we draw upon published animal and human studies to characterize the changes biomaterials undergo after implantation and the typical host responses, placing these in the context of clinical outcomes.

1 January 2016 in Acta Biomaterialia
Verified
Journal Article
Open access
NMNaside Mangir
Naside Mangir
ABAnthony James Bullock
Anthony James Bullock
SRSabiniano Roman
Sabiniano Roman
NONadir Osman
Nadir Osman
CCChristopher Chapple
Christopher Chapple
SMSheila Macneil
Sheila Macneil
An underlying abnormality in collagen turnover is implied in the occurrence of complications and recurrences after mesh augmented pelvic floor repair surgeries. Ascorbic acid is a potent stimulant of collagen synthesis. The aim of this study is to produce ascorbic acid releasing poly-lactic acid (PLA) scaffolds and evaluate them for their effects on extracellular matrix production and the strength of the materials. Scaffolds which contained either l-ascorbic acid (AA) and Ascorbate-2-Phosphate (A2P) were produced with emulsion electrospinning. The release of both drugs was measured by UV spectrophotometry. Human dermal fibroblasts were seeded on scaffolds and cultured for 2weeks. Cell attachment, viability and total collagen production were evaluated as well as mechanical properties. No significant differences were observed between AA, A2P, Vehicle and PLA scaffolds in terms of fibre diameter and pore size. The encapsulation efficiency and successful release of both AA and A2P were demonstrated. Both AA and A2P containing scaffolds were significantly more hydrophilic and stronger in both dry and wet states compared to PLA scaffolds. Fibroblasts produced more collagen on scaffolds containing either AA or A2P compared to cells grown on control scaffolds. This study is the first to directly compare the two ascorbic acid derivatives in a tissue engineered scaffold and shows that both AA and A2P releasing electrospun PLA scaffolds increased collagen production of fibroblasts to similar extents but AA scaffolds seemed to be more hydrophilic and stronger compared to A2P scaffolds. Mesh augmented surgical repair of the pelvic floor currently relies on non-degradable materials which results in severe complications in some patients. There is an unmet and urgent need for better pelvic floor repair materials. Our current understanding suggests that the ideal material should be able to better integrate into sites of implantation both biologically and mechanically. The impact of vitamin C on extracellular matrix production is well established but we in this study have undertaken a critical comparison of two derivatives of vitamin C as they are released from a biodegradable scaffold. This strategy proved to be equally useful with both derivatives in terms of new tissue production yet we observed significant differences in mechanical properties of these biomaterials.

21 July 2015 in Journal of Anatomy
Verified
Journal Article
Open access
PDF file
LZLeyla Zilic
Leyla Zilic
PGPhilippa E. Garner
Philippa E. Garner
TYTong Yu
Tong Yu
SRSabiniano Roman
Sabiniano Roman
JHJohn W. Haycock
John W. Haycock
SWStacy‐Paul Wilshaw
Stacy‐Paul Wilshaw
Current nerve tissue engineering applications are adopting xenogeneic nerve tissue as potential nerve grafts to help aid nerve regeneration. However, there is little literature that describes the exact location, anatomy and physiology of these nerves to highlight their potential as a donor graft. The aim of this study was to identify and characterise the structural and extracellular matrix (ECM) components of porcine peripheral nerves in the hind leg. Methods included the dissection of porcine nerves, localisation, characterisation and quantification of the ECM components and identification of nerve cells. Results showed a noticeable variance between porcine and rat nerve (a commonly studied species) in terms of fascicle number. The study also revealed that when porcine peripheral nerves branch, a decrease in fascicle number and size was evident. Porcine ECM and nerve fascicles were found to be predominately comprised of collagen together with glycosaminoglycans, laminin and fibronectin. Immunolabelling for nerve growth factor receptor p75 also revealed the localisation of Schwann cells around and inside the fascicles. In conclusion, it is shown that porcine peripheral nerves possess a microstructure similar to that found in rat, and is not dissimilar to human. This finding could extend to the suggestion that due to the similarities in anatomy to human nerve, porcine nerves may have utility as a nerve graft providing guidance and support to regenerating axons.