1 September 2013 in Géotechnique
A series of physical model tests was conducted for the active case of a rigid retaining wall subjected to horizontal translation. The behaviour of a granular retained soil was investigated experimentally using a set of precise miniature pressure cells and particle image velocimetry. The good agreement between the experimental results and the arch-action-based theories for lateral active earth pressure could confirm the arching effect behind the retaining walls in the active translation mode. The distribution of shear strain confirms that, for active wall movement, the failure zone is distinguished from the stationary zone by a shear band behind the wall.
1 August 2016 in Soils and Foundations
1 August 2014 in Engineering Geology
1 April 2012 in International Journal of Geotechnical Engineering
The frictional behavior of a block of moist silica sand No. 6 on a Teflon plate is studied thru a series of slip tests. A relation was found between the supports on the sides and toe and the stability of the sand block. The critical slope angles for the stability of the sand block on the Teflon plate were obtained for three cases of without supports, with only side supports and with both side and toe supports. Based on the results from slip tests, a series of undercut slope physical model tests were conducted where moist sand was uniformly layered inside a rigid acrylic frame fixed on a sloping Teflon plate. The model was instrumented by a set of miniature pressure cells buried inside the model and a row of potentiometers at the top of the slope model. A high speed camera with a capture speed of 500 frames per second was employed to record the crack initiation of the model. Moreover movement distributions of the slopes were recorded and analyzed using particle image velocimetry (PIV) and image pro...
1 August 2011 in Soils and Foundations
1 July 2022 in International Journal of Geomechanics
A narrow backfill refers to the limited space behind a retaining wall, constructed in front of an existing structure or rock face. It is known that the use of the classical analytical methods, developed for infinite half-spaces, is not appropriate for narrow backfills. In this study, the limit-equilibrium analysis with bilinear planar slip surfaces is employed and a theoretical methodology is proposed for the estimation of the active earth pressure inside a narrow backfill, considering the soil arching effect. The suggested approach can estimate the distribution of vertical, horizontal, and shear stresses everywhere inside the narrow backfill. It is observed that, as expected, the distribution of earth pressure against the retaining wall is curvilinear due to the arching effect. The influence of the backfill width, surcharge pressure, backfill internal friction, wall–soil interface friction, and rock face–soil interface friction on the earth pressure distribution is studied. The proposed methodology provides acceptable results when compared with pre-existing analytical and numerical studies. Therefore, the suggested approach can be used for the analysis of narrow backfill retaining walls.