Colin M. Baker

Colin M. Baker

Auto-generated profile, based on publicly available information

Colin M. Baker

Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
GGGraham S. Goh
Graham S. Goh
CBColin M. Baker
Colin M. Baker
STSaad Tarabichi
Saad Tarabichi
SCSean Clark
Sean Clark
MAMatthew S. Austin
Matthew S. Austin
JLJess H. Lonner
Jess H. Lonner

9 February 2023 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
STSaad Tarabichi
Saad Tarabichi
GGGraham S. Goh
Graham S. Goh
CBColin M. Baker
Colin M. Baker
ECEmanuele Chisari
Emanuele Chisari
ASAlisina Shahi
Alisina Shahi
JPJavad Parvizi
Javad Parvizi
Background: No single test has demonstrated absolute accuracy in the diagnosis of periprosthetic joint infection (PJI). Serological markers are often used as screening tools in the workup of patients with suspected PJI. This study aimed to determine the diagnostic utility of plasma D-dimer for PJI in a variety of clinical scenarios. Methods: This prospective study enrolled 502 patients undergoing revision hip or knee arthroplasty. PJI was defined per a modified version of the 2018 International Consensus Meeting (ICM) criteria. Plasma D-dimer, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and fibrinogen were measured preoperatively. Receiver operating characteristic curves were used to assess the utility of each biomarker in the diagnosis of PJI. Pairwise comparison with Bonferroni correction was performed to determine whether the differences in areas under the curve (AUCs) between the markers were significant. Results: Of the 412 patients included, 317 (76.9%) did not have an infection (aseptic group) and 95 (23.1%) had an infection (PJI group). All 4 serological markers, D-dimer (AUC, 0.860; sensitivity, 81.3%; specificity, 81.7%), CRP (AUC, 0.862; sensitivity, 90.4%; specificity, 70.0%), ESR (AUC, 0.833; sensitivity, 73.9%; specificity, 85.2%), and fibrinogen (AUC, 0.798; sensitivity, 74.7%; specificity, 75.4%), demonstrated comparable accuracy for the diagnosis of PJI (all p > 0.05). When examining the performance of the different inflammatory markers in diagnosing infection caused by indolent organisms, D-dimer demonstrated the highest sensitivity at 93.8%. Conclusions: We found that plasma D-dimer was noninferior to serum CRP and ESR in the diagnosis of PJI and may be a useful adjunct when screening patients undergoing revision total joint arthroplasty. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.

7 March 2022 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CBColin M. Baker
Colin M. Baker
CRCamilo Restrepo
Camilo Restrepo
WHWilliam J. Hozack
William J. Hozack