Chuntian Zhao

Chuntian Zhao

Auto-generated profile, based on publicly available information

Chuntian Zhao

Failure Mechanics and Engineering Disaster Prevention Key Laboratory of Sichuan Province, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2024 in Separation and Purification Technology
Verified
Journal Article
Closed access
FLFengxia Long
Fengxia Long
DGDanyal Ghani
Danyal Ghani
RHRongfu Huang
Rongfu Huang
CZChuntian Zhao
Chuntian Zhao

1 November 2013 in Wear
Verified
Journal Article
Closed access
RZRi Zhang
Ri Zhang
HLHaixiao Liu
Haixiao Liu
CZChuntian Zhao
Chuntian Zhao

7 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SZShizhong Zhang
Shizhong Zhang
HLHongmei Li
Hongmei Li
CZChuntian Zhao
Chuntian Zhao
Magnetic flux leakage (MFL) inspection is widely used in testing and evaluating of defects in ferromagnetic structures, providing important assurances for their safe operations. The calculation of MFL signals based on defects shape is critical for the accuracy of defect evaluation. The existing methods mainly include magnetic dipole model (MDM) and finite element method (FEM), while MDM is incapable of calculating the MFL fields of complex defects, and FEM is time-consuming for the MFL analysis. It is necessary to develop a method which can calculate MFL fields of arbitrary defects fast. In this paper, we propose the magnetic charge element method (MCEM) based on the microscopic mechanism of magnetization and the theory of MDM, which can quickly calculate the MFL fields of arbitrary defects. The effectiveness of the proposed method is verified by a series of simulations and MFL inspection experiments. The results show that the proposed method has the same accuracy as the existing methods. Compared with the FEM, the computation time is greatly reduced.

9 December 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHongmei Li
Hongmei Li
CZChuntian Zhao
Chuntian Zhao
FZFuchen Zhang
Fuchen Zhang
ZHZhiyuan Hu
Zhiyuan Hu
LDLi Ding
Li Ding
The effects of mechanical stress on the magnetic characteristics of materials indicates it possible to quantitatively measure and evaluate stress via the testing of stress-induced magnetic component. At present, however, the stress-associated magnetic component is extracted from the inducting magnetic field, which is mingled with the environmental magnetic field and the residual magnetic field of the materials. Both factors are difficult to be isolated, leading to (1) poor stress measuring precision; (2) misunderstanding of the mechanism between stress and the magnetic characteristics. In this paper, the relationships between the stresses and the excitation magnetic fields of three materials are investigated, with a proposed method to extract the stress-induced component. The results show that (1) the stress effect on the excitation magnetic field is evident, and a method to extract the stress-induced magnetic component is proposed; (2) the relationship between the stress and the stress-induced magnetic component is affected by the material’s permeability and conductivity. The findings and proposed methods are helpful to enrich the understanding of the magneto-mechanical effect and improve the stress measurement.

19 June 2016
Verified
Conference Paper
Closed access
PDF file
YLYanyao Li
Yanyao Li
TZTianyu Zhang-Jin
Tianyu Zhang-Jin
WRWeidong Ruan
Weidong Ruan
Yong BaiYong Bai
Yong Bai
CZChuntian Zhao
Chuntian Zhao
Pipelines are of most importance to subsea systems. The leakage of pipelines which may be caused by aging or corrosion will lead to serious environmental damage and significant economic losses. In this paper, a submarine pipeline leak detection system is developed to protect environment and also improve the safety of subsea system via quick detection and relatively correct location. The leak detection system includes data acquisition devices, wireless communication devices, the calculation part is also involved, like data processing module, leak detection module, pattern recognition module and positioning module. The corrected flow balance principle and a statistical analysis method, namely Wald’s Sequential Probability Ratio Test (SPRT), are used to decide whether it is leak-free or leak-present. Besides, a pattern recognition system is developed to minimize false alarms. The method of Hydraulic Grade Line was employed to locate the leakage. Our study provides a quick response to leak detection as well as leak location. A quick and convenient method to leak detection and location is provided by this paper.

1 April 2026 in NDT & E International
Verified
Journal Article
Closed access
ZHZhiyuan Hu
Zhiyuan Hu
MGMuhong Guo
Muhong Guo
RHRanran Huang
Ranran Huang
CZChuntian Zhao
Chuntian Zhao
HLHongmei Li
Hongmei Li