Gernot Plank

Gernot Plank

Auto-generated profile, based on publicly available information

Gernot Plank

Gottfried Schatz Research Center: Division of Medical Physics and Biophysics, Medical University of Graz, Graz, Austria

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2012 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JBJ. D. Bayer
J. D. Bayer
RBR. C. Blake
R. C. Blake
GPG. Plank
G. Plank
NTN. A. Trayanova
N. A. Trayanova

1 January 2008 in Progress in Biophysics and Molecular Biology
Verified
Journal Article
Closed access
EVE.J. Vigmond
E.J. Vigmond
RSRodrigo Weber Dos Santos
Rodrigo Weber Dos Santos
APA.J. Prassl
A.J. Prassl
MDM. Deo
M. Deo
GPG. Plank
G. Plank

13 November 2011 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
SNSteven A. Niederer
Steven A. Niederer
EKEric Kerfoot
Eric Kerfoot
ABAlan P. Benson
Alan P. Benson
MBMiguel O. Bernabeu
Miguel O. Bernabeu
OBOlivier Bernus
Olivier Bernus
NSNic P. Smith
Nic P. Smith
Ongoing developments in cardiac modelling have resulted, in particular, in the development of advanced and increasingly complex computational frameworks for simulating cardiac tissue electrophysiology. The goal of these simulations is often to represent the detailed physiology and pathologies of the heart using codes that exploit the computational potential of high-performance computing architectures. These developments have rapidly progressed the simulation capacity of cardiac virtual physiological human style models; however, they have also made it increasingly challenging to verify that a given code provides a faithful representation of the purported governing equations and corresponding solution techniques. This study provides the first cardiac tissue electrophysiology simulation benchmark to allow these codes to be verified. The benchmark was successfully evaluated on 11 simulation platforms to generate a consensus gold-standard converged solution. The benchmark definition in combination with the gold-standard solution can now be used to verify new simulation codes and numerical methods in the future.

1 December 2003 in Journal of Electrocardiology
Verified
Journal Article
Closed access
EVEdward J Vigmond
Edward J Vigmond
MHMatt Hughes
Matt Hughes
GPG Plank
G Plank
LLL.JOshua Leon
L.JOshua Leon

1 July 2021 in Medical Image Analysis
Verified
Journal Article
Open access
KGKarli Gillette
Karli Gillette
MGMatthias Gsell
Matthias Gsell
APAnton J. Prassl
Anton J. Prassl
EKElias Karabelas
Elias Karabelas
URUrsula Reiter
Ursula Reiter
GPGernot Plank
Gernot Plank
Cardiac digital twins (Cardiac Digital Twin (CDT)s) of human electrophysiology (Electrophysiology (EP)) are digital replicas of patient hearts derived from clinical data that match like-for-like all available clinical observations. Due to their inherent predictive potential, CDTs show high promise as a complementary modality aiding in clinical decision making and also in the cost-effective, safe and ethical testing of novel EP device therapies. However, current workflows for both the anatomical and functional twinning phases within CDT generation, referring to the inference of model anatomy and parameters from clinical data, are not sufficiently efficient, robust and accurate for advanced clinical and industrial applications. Our study addresses three primary limitations impeding the routine generation of high-fidelity CDTs by introducing; a comprehensive parameter vector encapsulating all factors relating to the ventricular EP; an abstract reference frame within the model allowing the unattended manipulation of model parameter fields; a novel fast-forward electrocardiogram (Electrocardiogram (ECG)) model for efficient and bio-physically-detailed simulation required for parameter inference. A novel workflow for the generation of CDTs is then introduced as an initial proof of concept. Anatomical twinning was performed within a reasonable time compatible with clinical workflows (<4h) for 12 subjects from clinically-attained magnetic resonance images. After assessment of the underlying fast forward ECG model against a gold standard bidomain ECG model, functional twinning of optimal parameters according to a clinically-attained 12 lead ECG was then performed using a forward Saltelli sampling approach for a single subject. The achieved results in terms of efficiency and fidelity demonstrate that our workflow is well-suited and viable for generating biophysically-detailed CDTs at scale.

1 October 2017 in Journal of Computational Physics
Verified
Journal Article
Open access
ANAurel Neic
Aurel Neic
FCFernando O. Campos
Fernando O. Campos
APAnton J. Prassl
Anton J. Prassl
SNSteven A. Niederer
Steven A. Niederer
MBMartin Bishop
Martin Bishop
GPGernot Plank
Gernot Plank
Anatomically accurate and biophysically detailed bidomain models of the human heart have proven a powerful tool for gaining quantitative insight into the links between electrical sources in the myocardium and the concomitant current flow in the surrounding medium as they represent their relationship mechanistically based on first principles. Such models are increasingly considered as a clinical research tool with the perspective of being used, ultimately, as a complementary diagnostic modality. An important prerequisite in many clinical modeling applications is the ability of models to faithfully replicate potential maps and electrograms recorded from a given patient. However, while the personalization of electrophysiology models based on the gold standard bidomain formulation is in principle feasible, the associated computational expenses are significant, rendering their use incompatible with clinical time frames.