1 November 2001 in Clinical Biomechanics
1 May 2000 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
A widely used method of treatment for unstable tibial shaft fractures is unilateral external fixation. The majority of fixators act as three distinct devices: an intra-operative reduction device, a device to maintain fracture alignment during healing and an aid to healing by allowing movement at the fracture site. Conventional operative techniques require the surgeon to manipulate a number of degrees of freedom at once, making reduction of the fracture difficult, and results in the fixator being out of alignment with the long axis of the bone. An operative method has been developed that separates reduction and fixation. A dedicated device has been designed to improve the per-operative control of fracture fragments during fracture reduction. The device has been used in clinical trials for the reduction of 22 diaphyseal tibial fractures. Compared with previous operative techniques there has been a saving of 53 per cent in fracture reduction time and an overall saving of 10 per cent in operating time. Fracture alignment has been improved compared with reductions achieved with a fixator which potentially improves healing and lowers the rate of malunion. In each case the fixator has been applied in alignment with the bone, improving dynamization and reducing the likelihood of malunion due to fixator cam slippage.
1 April 2001 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
This paper presents a new design for a device to monitor the motion of fracture fragments in diaphyseal tibial fractures. The device measures the motion that occurs at the fracture site when loaded by gait or by manipulation. It has undergone rigorous calibration and acceptance trials. The device has been used in ethically approved research clinics held at the North Staffordshire Hospital (40 patients). The paper presents a selection of results obtained using the new device. The results demonstrate several new ways of assessing fracture healing by examining fracture site motion. The following conclusions were drawn: 1. If fracture monitoring devices are to be attached to bone screws, it is essential to minimize bone screw errors. To do this, each patient must have similar bone screw lengths, orientations, alignment and siting. This is only achievable using a peroperative reduction device. 2. If fracture stiffness is to be used as a measure of fracture healing, load rate should be controlled; at the very least strain rate should be controlled. 3. It is imperative that fracture stiffness be measured in more than one plane by a biplanar device so that asymmetry may be accommodated. 4. Fracture stiffness, on its own, is probably not a sufficiently rigorous measure of healing end-point. The quantifiably viscoelastic properties of healing callus should be taken into account.
1 May 2016 in The Bone & Joint Journal
In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment. We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty. Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up. At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5). HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term. Cite this article: Bone Joint J 2016;98-B:601–7.
1 January 1997 in Journal of Tribology
This paper describes a combined theoretical and experimental investigation of the eight oil film stiffness and damping coefficients for a novel low impedance hydrodynamic bearing. The novel design incorporates a recess in the bearing surface which is connected to a standard commercial gas bag accumulator; this arrangement reduces the oil film dynamic stiffness and leads to improved machine response and stability. A finite difference method was used to solve Reynolds equation and yield the pressure distribution in the bearing oil film. Integration of the pressure profile then enabled the fluid film forces to be evaluated. A perturbation technique was used to determine the dynamic pressure components, and hence to determine the eight oil film stiffness and damping coefficients. Experimental data was obtained from a laboratory test rig in which a test bearing, floating on a rotating shaft, was excited by a multi-frequency force signal. Measurements of the resulting relative movement between bearing and journal enabled the oil film coefficients to be measured. The results of the work show good agreement between theoretical and experimental data, and indicate that the oil film impedance of the novel design is considerably lower than that of a conventional bearing.
7 April 2013 in Journal of Medical Engineering
This paper examines the question;“ does permanent laser marking affect the mechanical performance of a metallic medical component?” The literature review revealed the surprising fact that very little has been presented or studied even though intuition suggests that its effect could be detrimental to a component's fatigue life. A brief investigation of laser marking suggests that defects greater than 25 μm are possible. A theoretical investigation further suggests that this is unlikely to cause issues with relation to fast fracture but is highly likely to cause fatigue life issues. An experimental investigation confirmed that laser marking reduced the fatigue life of a component. This combination of lines of evidence suggests, strongly, that positioning of laser marking is highly critical and should not be left to chance. It is further suggested that medical device designers, especially those related to orthopaedic implants, should consider the position of laser marking in the design process. They should ensure that it is in an area of low stress amplitude. They should also ensure that they investigate worst-case scenarios when considering the stress environment; this, however, may not be straightforward.