Kathleen H. McCarthy

Kathleen H. McCarthy

Auto-generated profile, based on publicly available information

Kathleen H. McCarthy

Division of Trauma and Burn Surgery, Children’s National Hospital , Washington, DC 20010

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2024 in Journal of the American Medical Informatics Association
Verified
Journal Article
Closed access
PDF file
MKMary S Kim
Mary S Kim
BPBeomseok Park
Beomseok Park
GSGenevieve J Sippel
Genevieve J Sippel
AMAaron H Mun
Aaron H Mun
WYWanzhao Yang
Wanzhao Yang
RBRandall S Burd
Randall S Burd
Human monitoring of personal protective equipment (PPE) adherence among healthcare providers has several limitations, including the need for additional personnel during staff shortages and decreased vigilance during prolonged tasks. To address these challenges, we developed an automated computer vision system for monitoring PPE adherence in healthcare settings. We assessed the system performance against human observers detecting nonadherence in a video surveillance experiment. The automated system was trained to detect 15 classes of eyewear, masks, gloves, and gowns using an object detector and tracker. To assess how the system performs compared to human observers in detecting nonadherence, we designed a video surveillance experiment under 2 conditions: variations in video durations (20, 40, and 60 seconds) and the number of individuals in the videos (3 versus 6). Twelve nurses participated as human observers. Performance was assessed based on the number of detections of nonadherence. Human observers detected fewer instances of nonadherence than the system (parameter estimate −0.3, 95% CI −0.4 to −0.2, P < .001). Human observers detected more nonadherence during longer video durations (parameter estimate 0.7, 95% CI 0.4-1.0, P < .001). The system achieved a sensitivity of 0.86, specificity of 1, and Matthew’s correlation coefficient of 0.82 for detecting PPE nonadherence. An automated system simultaneously tracks multiple objects and individuals. The system performance is also independent of observation duration, an improvement over human monitoring. The automated system presents a potential solution for scalable monitoring of hospital-wide infection control practices and improving PPE usage in healthcare settings.

6 August 2024 in American Journal of Infection Control
Verified
Journal Article
Closed access
MKMary S. Kim
Mary S. Kim
ASAleksandra Sarcevic
Aleksandra Sarcevic
GSGenevieve J. Sippel
Genevieve J. Sippel
KMKathleen H. McCarthy
Kathleen H. McCarthy
EWEleanor A. Wood
Eleanor A. Wood
RBRandall S. Burd
Randall S. Burd