1 September 2016 in Journal of Shoulder and Elbow Surgery
26 January 2009 in Journal of General Physiology
The slow-channel congenital myasthenic syndrome (SCCMS) is a disorder of the neuromuscular junction caused by gain-of-function mutations to the muscle nicotinic acetylcholine (ACh) receptor (AChR). Although it is clear that the slower deactivation time course of the ACh-elicited currents plays a central role in the etiology of this disease, it has been suggested that other abnormal properties of these mutant receptors may also be critical in this respect. We characterized the kinetics of a panel of five SCCMS AChRs (αS269I, βV266M, ɛL221F, ɛT264P, and ɛL269F) at the ensemble level in rapidly perfused outside-out patches. We found that, for all of these mutants, the peak-current amplitude decreases along trains of nearly saturating ACh pulses delivered at physiologically relevant frequencies in a manner that is consistent with enhanced entry into desensitization during the prolonged deactivation phase. This suggests that the increasingly reduced availability of activatable AChRs upon repetitive stimulation may well contribute to the fatigability and weakness of skeletal muscle that characterize this disease. Also, these results emphasize the importance of explicitly accounting for entry into desensitization as one of the pathways for burst termination, if meaningful mechanistic insight is to be inferred from the study of the effect of these naturally occurring mutations on channel function. Applying a novel single-channel–based approach to estimate the contribution of Ca2+ to the total cation currents, we also found that none of these mutants affects the Ca2+-conduction properties of the AChR to an extent that seems to be of physiological importance. Our estimate of the Ca2+-carried component of the total (inward) conductance of wild-type and SCCMS AChRs in the presence of 150 mM Na+, 1.8 mM Ca2+, and 1.7 mM Mg2+ on the extracellular side of cell-attached patches turned out be in the 5.0–9.4 pS range, representing a fractional Ca2+ current of ∼14%, on average. Remarkably, these values are nearly identical to those we estimated for the NR1-NR2A N-methyl-d-aspartate receptor (NMDAR), which has generally been considered to be the main neurotransmitter-gated pathway of Ca2+ entry into the cell. Our estimate of the rat NMDAR Ca2+ conductance (using the same single-channel approach as for the AChR but in the nominal absence of extracellular Mg2+) was 7.9 pS, corresponding to a fractional Ca2+ current of 13%.
1 November 2015 in Journal of Surgical Research
1 November 2020 in Journal of Orthopaedics
23 January 2022 in Cureus
Prosthetic joint infection (PJI) and metallosis are known complications of total hip arthroplasty (THA) and are causes for revision surgeries. Articulating metal surfaces in total hip arthroplasty with corrosion at modular junctions can lead to the release of metal ions that can cause an immune-mediated biological reaction. There are few cases in the literature of both coinciding together. We describe a case of chronic Cutibacertium acnes PJI and metallosis co-occurring in a 64-year-old female after THA with a dual mobility construct. After undergoing uncomplicated left THA through a modified Hardinge approach, the patient dislocated anteriorly after four weeks and required revision of her acetabular component to a less anteverted position. Nine months later, she presented with hip pain and was found to have medial wall fragmentation and cystic changes around the greater trochanter on radiographs, elevated serum cobalt and chromium levels, and a benign noninfected hip aspiration. During her revision procedure, intraoperative histopathology showed over 20 neutrophils per high power field in multiple samples and fluid aspirates demonstrating Gram-positive rods. She was also found to have pseudotumor formation with the erosion of the anterior and posterior capsules with black debris on the femoral stem trunnion and the backside of the modular dual mobility liner. An antibiotic spacer was placed and her cultures grew into C. acnes. She completed six weeks of intravenous ceftriaxone and, during her "drug holiday," she dislocated her spacer and was found to have a lateral femoral diaphyseal stress fracture at the distal end of her spacer. She underwent stage II of her revision, and while the plan was to continue her antibiotics, she had an adverse reaction and was transitioned to oral antibiotics for six months. Due to delayed healing, she underwent additional irrigation and debridement with head and liner exchange. Her wound then healed, and at her one-year final follow-up, she was able to ambulate without pain, and her serum inflammatory and metal ion levels were within normal limits. Concurrent PJI and metallosis from articulating metal interfaces can occur, and a high index of suspicion is necessary to properly manage both conditions.
1 January 2021 in Orthopedic Research and Reviews
Introduction: Numerous thermal free radical stabilization techniques are used in the production of highly cross-linked polyethylene (HXLPE) to improve oxidative stability. Little knowledge exists on the effects of in vivo time on the mechanical properties of HXLPE. The purpose of this study was to determine if free radical stabilization of HXLPE impacts mechanical properties as well as oxidative stability of acetabular liner rims after extended in vivo time. Methods: Retrieved and control remelted, single annealed and sequentially annealed HXLPE liner rims were tested for mechanical properties. Oxidation was measured with FTIR spectroscopy and crystalline phase composition measured with Raman spectroscopy. Results: No correlation was found between in vivo, ex vivo time and hardness for annealed groups. A statistically significant difference in hardness was identified between free radical stabilization groups. No correlation between maximum rim oxidation and in vivo time was found. Detectable levels of rim oxidation were present in 100% of single annealed, 75% of sequentially annealed, and 25% of remelted retrieved liners. Single and sequentially annealed liners demonstrated oxidation and increased crystallinity. Rim mechanical properties change in vivo for implant types. With in vivo time, retrieved remelted HXLPE demonstrated decreased mechanical properties, whereas retrieved single and sequentially annealed HXLPE properties remained stable. All liner cohorts demonstrated evidence of rim oxidation. Subsequent changes in crystallinity were only observed in oxidized annealed liners. Conclusion: HXLPE acetabular liner rims show evidence of in vivo mechanical property degradation, notably in remelted HXLPE, which may be a risk factor in rim fracture and catastrophic implant failure.