1 March 2020 in Review of Scientific Instruments
The beam energy of the circular electron–positron collider should be measured precisely to the order of 1 MeV, in order to decrease the uncertainty of the Higgs/W/Z bosons’ mass measurement. For this purpose, a lepton bunch is extracted from the collider and collides with an Yttrium–Aluminum–Garnet laser pulse. After the inverse Compton scattering, the main beam and the scattered beam pass through an analytical magnetic field and are deflected to different angles. At the end of the drift beam pipes, the deflecting distances are detected with the spatial resolution of several microns. The systematic uncertainties caused by the detector arrangement, the magnetic field, the angle between the detector plane and the incident beam, and the synchrotron radiation are discussed in detail. The simulations of the statistical errors are given with a toy Monte Carlo sample. With some proper corrections, the beam energy uncertainty of the Higgs mode is around 2 MeV. Our method is applicable to different operating modes of the collider.
1 January 2021 in Acta Physica Sinica
The accurate calibration of the beam energy of the circular electron-positron collider (CEPC) is performed to accurately measure the mass width of Higgs particle and the mass of W/Z boson, thus providing the basic experimental basis for the accurate test of the standard model. Based on this, the error control of beam energy is required to be at a level of 10–5. Compton backscattering method is suitable for high precision calibration of beam energy in the Hundred GeV high energy electron collider. In this work, the CEPC beam energy is predicted to reach a theoretical accuracy of about 3 MeV by using the accurate measurement of the scattered photon energy after microwave electron Compton backscattering. Firstly, TM01 mode microwave transmission in circular waveguide is selected according to the design requirements, and the electromagnetic field distribution and Poynting vector under this condition are solved. According to the photon distribution and transmission in the waveguide, the design idea is proposed to simplify the complexity of calculation, and the parameters conforming to the design requirements are solved by combining the simultaneous equations of the high purity germanium detector sensitivity and the background of synchrotron radiation. Using the optimal set of waveguide inner diameter, microwave wavelength and electron incident angle data, the derivative of the differential scattering cross section with respect to energy and the collision brightness are obtained when the microwave power is 100 W. The scattered photon density of 15 MeV energy is further obtained, and the signal-to-noise ratio is analyzed according to the photon density of synchrotron radiation under this energy. The feasibility of the scheme is demonstrated theoretically and the technical difficulties and problems to be further studied are discussed.
21 September 2026 in EPJ Techniques and Instrumentation
Accurate mass determination of nuclear materials in large-volume containers is hindered by geometric constraints that preclude conventional 4 π detector encapsulation. This study optimizes the design of a semi-wrapped neutron multiplicity counter tailored for kilogram-scale material assay under restricted access conditions. Based on Geant4 Monte-Carlo simulations, a detection system comprising 60 3 He proportional tubes was optimized. Detector pressure, active length, and moderator assembly were systematically evaluated to maximize the figure of merit (FOM). System performance was assessed using material samples ranging from 1000 g to 5000 g. The optimized detector achieved a detection efficiency of 12.85% and a die-away time of 35 μs, yielding a FOM of 2.17. Mass inversion results exhibited stable relative errors ranging 4.76% to 5.60% across the entire mass range. This work confirms that a semi-wrapped configuration can achieve performance metrics comparable to those of traditional $\mathrm{4\pi }$ systems. The proposed methodology offers a viable solution for passive neutron multiplicity counting in geometrically constrained storage and reprocessing scenarios.