Pezhman Sasanpour

Pezhman Sasanpour

Auto-generated profile, based on publicly available information

Pezhman Sasanpour

Department of Medical Physics and Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SJSomayeh Jafarinejad
Somayeh Jafarinejad
MGMahmoud Ghazi-Khansari
Mahmoud Ghazi-Khansari
FGForough Ghasemi
Forough Ghasemi
PSPezhman Sasanpour
Pezhman Sasanpour
MHMohammad Reza Hormozi-Nezhad
Mohammad Reza Hormozi-Nezhad
Catecholamine neurotransmitters, generally including dopamine (DA), epinephrine (EP) and norepinephrine (NE) are known as substantial indicators of various neurological diseases. Simultaneous detection of these compounds and their metabolites is highly recommended in early clinical diagnosis. To this aim, in the present contribution, a high performance colorimetric sensor array has been proposed for the detection and discrimination of catecholamines based on their reducing ability to deposit silver on the surface of gold nanorods (AuNRs). The amassed silver nanoshell led to a blue shift in the longitudinal localized surface plasmon resonance (LSPR) peak of AuNRs, creating a unique pattern for each of the neurotransmitters. Hierarchical cluster analysis (HCA) and linear discriminate analysis (LDA) pattern recognition techniques were employed to identify DA, EP and NE. The proposed colorimetric array is able to differentiate among individual neurotransmitters as well as their mixtures, successfully. Finally, it was shown that the sensor array can identify these neurotransmitters in human urine samples.

5 September 2011 in Journal of Materials Chemistry
Verified
Journal Article
Closed access
PDF file
EMEbrahim Mehdipoor
Ebrahim Mehdipoor
MAMohsen Adeli
Mohsen Adeli
MBMasoumeh Bavadi
Masoumeh Bavadi
PSPezhman Sasanpour
Pezhman Sasanpour
BRBizhan Rashidian
Bizhan Rashidian
Iron oxide nanoparticles, γ-Fe2O3NP, were deposited onto the surface of multi-walled carbon nanotubes and CNT/γ-Fe2O3NP hybrid nanomaterials were obtained. Then linear-dendritic ABA type block copolymers consisting of polyethylene glycol as B block and poly(citric acid) as A block, PCA–PEG–PCA, were synthesized and cisplatin (cis-diamminedichloroplatinum (CDDP)—a platinum-based chemotherapy drug) was conjugated with their carboxyl functional groups and CDDP/PCA–PEG–PCA anticancer prodrugs were prepared. Noncovalent interactions between CDDP/PCA–PEG–PCA anticancer prodrugs and CNT/γ-Fe2O3NP hybrid nanomaterials led to CDDP/PCA–PEG–PCA/CNT/γ-Fe2O3NP drug delivery systems. There are several key features of these hybrid drug delivery systems: (i) their ability to cross cell membranes and also high surface area per unit weight for high drug loading assigned to CNTs, (ii) high functionality, water solubility and biocompatibility assigned to PCA–PEG–PCA linear-dendritic copolymers and (iii) targeting tumors using a magnetic field assigned to γ-Fe2O3 nanoparticles. The efficacy of drug delivery systems for killing the cancer cells and targeting the drugs towards tumors was investigated.

13 January 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
MVMohaddeseh Vafaiee
Mohaddeseh Vafaiee
RMRaheleh Mohammadpour
Raheleh Mohammadpour
MVManouchehr Vossoughi
Manouchehr Vossoughi
EAElham Asadian
Elham Asadian
MJMahyar Janahmadi
Mahyar Janahmadi
PSPezhman Sasanpour
Pezhman Sasanpour
Carbon nanotubes (CNTs) coatings have been shown over the past few years as a promising material for neural interface applications. In particular, in the field of nerve implants, CNTs have fundamental advantages due to their unique mechanical and electrical properties. In this study, carbon nanotubes multi-electrode arrays (CNT-modified-Au MEAs) were fabricated based on gold multi-electrode arrays (Au-MEAs). The electrochemical impedance spectra of CNT-modified-Au MEA and Au-MEA were compared employing equivalent circuit models. In comparison with Au-MEA (17 Ω), CNT-modified-Au MEA (8 Ω) lowered the overall impedance of the electrode at 1 kHz by 50%. The results showed that CNT-modified-Au MEAs have good properties such as low impedance, high stability and durability, as well as scratch resistance, which makes them appropriate for long-term application in neural interfaces.

18 March 2017 in Microchimica Acta
Verified
Journal Article
Closed access
PDF file
AKAli Karimizefreh
Ali Karimizefreh
FMFarzaneh Aghakhani Mahyari
Farzaneh Aghakhani Mahyari
MVMaryam VaezJalali
Maryam VaezJalali
RMRaheleh Mohammadpour
Raheleh Mohammadpour
PSPezhman Sasanpour
Pezhman Sasanpour

17 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SBSaeedesadat Badieyan
Saeedesadat Badieyan
ADArezou Dilmaghani-Marand
Arezou Dilmaghani-Marand
MHMohammad Javad Hajipour
Mohammad Javad Hajipour
AAAli Ameri
Ali Ameri
MRMohammad Reza Razzaghi
Mohammad Reza Razzaghi
PSPezhman Sasanpour
Pezhman Sasanpour
The polarization imaging technique is a powerful approach to probe microstructural and optical information of biological structures (e.g., tissue samples). Here, we have studied the polarization properties of different bacterial colonies in order to evaluate the possibility of bacterial detection and discrimination. In this regard, we have taken the backscattering Mueller matrix images of four different bacteria colonies (i.e., Escherichia coli,Lactobacillus rhamnosus,Rhodococcus erythropolis, andStaphylococcus aureus). Although the images have the potential to distinguish qualitatively different bacterial colonies, we explored more accurate and quantitative parameters criteria for discrimination of bacterial samples; more specifically, we have exploited the Mueller matrix polar decomposition (MMPD),frequency distribution histogram (FDH), and central moment analysis method. The outcomes demonstrated a superior capacity of Mueller matrix imaging, MMPD, and FDH in bacterial colonies identification and discrimination. This approach might pave the way for a reliable, efficient, and cheap way of identification of infectious diseases.

27 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MVMohaddeseh Vafaiee
Mohaddeseh Vafaiee
MVManouchehr Vossoughi
Manouchehr Vossoughi
RMRaheleh Mohammadpour
Raheleh Mohammadpour
PSPezhman Sasanpour
Pezhman Sasanpour
Multi electrode arrays (MEA) have been exploited in different electrophysiological applications. In neurological applications, MEAs are the vital interfaces between neurons and the electronic circuits with dual role; transmitting electric signal to the neurons and converting neural activity to the electric signal. Since the performance of the electrodes has a direct effect on the quality of the recorded neuronal signal, as well as the stimulation, the true choice of electrode material for MEA is crucial. Gold is one of the best candidates for fabrication of MEAs due to its high electrical conductivity, biocompatibility and good chemical stability. However, noble metals such as gold do not adhere well to the glass substrate. Consequently while exposing to the water, gold films are damaged, which impose limitations in the exploiting of gold thin films as the electrode. In this paper, a simple and cost effective method for the fabrication of gold electrode arrays is proposed. Using various mechanical (adhesion test and scratch strength), morphological (AFM and SEM) and electrochemical methods, the fabricated electrodes are characterized. The results show that the fabricated electrode arrays have significantly high scratch strength and stability within the aqueous medium. In addition, the electrical properties of the electrodes have been improved. The proposed electrodes have the potential to be exploited in other applications including electronics, electrochemistry, and biosensors.