11 January 2016 in Journal of Ophthalmology
Aim. To asses both choroidal thickness differences among Alzheimer’s type dementia (ATD) patients, mild cognitive impairment (MCI) patients, and healthy control (C) subjects and choroidal thickness relationships with cognitive performance.Methods. A total of 246 eyes of 123 people (41 ATD, 38 MCI, and 44 healthy C subjects) were included in this study. Complete ophthalmological and neurological examination was performed in all subjects. Choroidal thicknesses (CT) were measured at seven locations: the fovea, 500-1500-3000 μm temporal and 500-1500-3000 μm nasal to the fovea by enhanced depth imaging optical coherence tomography (EDI-OCT). Detailed neurological examination including mini mental state examination (MMSE) test which evaluates the cognitive function was applied to all participants.Results. The ages and genders of all participants were similar in all groups. Compared with healthy C subjects, the CT measurements at all regions were significantly thinner both in patients with ATD and in patients with MCI than in healthy C subjects (). The MMSE scores were significantly different among ATD patients, MCI patients, and healthy C subjects. They were,, andin ATD, MCI, and healthy controls, respectively (). There were also significant correlation between MMSE score and choroidal thickness at each location ().Conclusions. CT was reduced in ATD patients and MCI patients. Since vascular structures were affected in ATD patients and MCI patients, they had thin CT. Besides CT was correlated with degree of cognitive impairment. Therefore CT may be a new biomarker in diagnosis and follow-up of MCI and ATD patients.
2 June 2016 in Optics Letters
It is technically difficult to construct wide-angle fundus imaging devices due to the complexity of conventional transpupillary illumination and imaging mechanisms. We report here a new method, i.e., trans-palpebral illumination, for wide-angle fundus photography without the need for pupil dilation. By constructing a smartphone-based prototype imaging device, we demonstrated a 152° view in a single-shot image. The unique combination of low-cost smartphone design and automatic illumination optimization promises an affordable solution to conduct telemedicine assessment of eye diseases, which will improve access to eye care for patients in rural and underserved areas.
29 November 2016 in Journal of Ophthalmology
1 February 2018 in Retina
This study is to develop a low-cost, easy-to-use, wide-field smartphone fundus video camera to enable affordable point-of-care examination and telemedicine. The wide-field smartphone fundus camera is based on a unique design of miniaturized indirect ophthalmoscopy. For proof-of-concept prototype, we used a Samsung Galaxy S6 smartphone and all off-the-shelf components. A fiber coupled LED was used to deliver illumination light through a 1 mm micro mirror, which was conjugated to the subject pupil plane, for retinal illumination. A 60D ophthalmic lens was used to image the retina through the eye, and a plano-convex lens with 90 mm focal length was used to relay the retinal image to the smartphone camera. A totally wireless smartphone fundus camera was constructed, with a whole weight of 255 g. This device allowed both snapshot fundus photography and continuous video recording. 92° field of view (FOV) was achieved in single-shot images. Optic disc, macula, and retinal blood vasculatures can be clearly observed with image quality comparable to standard fundus camera. Miniaturized indirect ophthalmoscopy enabled a low-cost, portable, wide-field smartphone fundus camera, which can foster telemedicine and clinical deployments of wide-field fundus photography for eye disease screening, diagnosis and treatment assessment.
3 December 2014 in Journal of Ophthalmology
Purpose.To examine the macular findings obtained with spectral domain optical coherence tomography (SD OCT) in infants with retinopathy of prematurity (ROP).Materials and Methods.The macular SD OCT images of 190 premature infants were analyzed. Data regarding central foveal thickness (CFT), cystoid macular edema (CME), and cyst grading were compared. The relationships of CFT with gestational age and birth weight were investigated.Results.The results were obtained from 358 eyes of 179 infants (81 females and 98 males) of a mean gestational age ofweeks and a mean birth weight of g. ROP was diagnosed in 126 eyes and CME in 139 eyes. A significantly greater percentage of eyes with ROP were found to have CME (54%) compared to eyes without ROP (31%;). The incidence of CME was 46.3% for stage 1 ROP, 57.1% for stage 2, and 87.5% for stage 3. There was a weakly inverse correlation between CFT, gestational age, and birth weight (,;,, resp., Spearman correlation test).Conclusions.High-quality SD OCT images can be obtained from premature infants using the iVue system. Severity and frequency of CME in premature infants increase as stage of ROP increases.
8 June 2018 in Scientific Reports
In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90° fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.