Fahmy Bendary

Fahmy Bendary

Auto-generated profile, based on publicly available information

Fahmy Bendary

Electrical Engineering Department, Faculty of Engineering Shoubra, Benha University, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2020 in IEEE Access
Verified
Journal Article
Open access
ZEZeinab Elkady
Zeinab Elkady
NANaser M.B. Abdel-Rahim
Naser M.B. Abdel-Rahim
AMAhmed A. Mansour
Ahmed A. Mansour
FBFahmy M. Bendary
Fahmy M. Bendary
The dynamic voltage restorer’s (DVR) transient, steady-state, and dynamic responses are essential requirements for protecting sensitive loads against upstream voltage disturbances via the DVR’s ride-through capabilities. DVRs also look after transient oscillation at the instant of entering, and /or exiting by the DVR. This paper presents an enhanced, optimized, and less complex DVR control system structure, which is capable of improving the transient, steady-state, and dynamic responses as well as eliminating inherent transient oscillations. The control system comprises a closed-loop feedback control signal and feedforward upstream disturbance detection signal. Incorporating the feedforward term helps, dramatically, in improving the system response and eliminating the transient oscillations in the load voltage. The error signals are adapted using a PI controller to make the load voltage faithfully track its predefined reference waveform. The controller is implemented in the dq synchronous rotating reference frame. The parameters of the PI controller are selected using modern population-based optimization called the Harris Hawks Optimization (HHO) technique. The results obtained using the HHO technique are compared with two other optimization algorithms, namely Particle Swarm Optimization (PSO) and Whale Optimization Algorithm (WOA). The results show that the HHO gives the best system response. The system is simulated using MATLAB/Simulink and the validation via Typhoon HIL402 real-time emulator. Both HIL402 validation and simulation results show that the proposed control scheme recovers normal operation against voltage disturbance within approximately 1.2 milliseconds without overshoot with steady-state error near zero and significantly dampens the inherent voltage oscillation that occurs at the instant of DVR entrance and/or exit.

6 January 2021 in Journal of Electrical Systems and Information Technology
Verified
Journal Article
Open access
PDF file
MFMohamed Fayez
Mohamed Fayez
MMMohamed Mandor
Mohamed Mandor
MEMohamed El-Hadidy
Mohamed El-Hadidy
FBFahmy Bendary
Fahmy Bendary
Inter-area oscillations are, by far, the most detrimental oscillation category to the integrity of synchronously interconnected power systems. Inter-area oscillations are characterized by the inherent weak damping. The inherent poor damping associated with the inter-area oscillations leaves open wide probabilities for irrevocable widespread blackouts with the consequent eventual devastating outcomes measured in terms of the huge economic casualties and the possible human fatalities. The main purpose of this work is to mitigate inter-area power oscillations. This article explores the effectiveness of dual thyristor controlled braking resistor units with Interval Type-2 fuzzy-based centralized architecture for neutralizing the jeopardy of inter-area power oscillations in Kundur’s two-area test system using MATLAB™/Simulink environment. The effectiveness of the proposed scheme is examined by considering four case studies with different degrees of severity. The simulation results show that the proposed scheme is simple yet effective in treating the inter-area oscillations appropriately under the considered case studies.

9 July 2020 in Bulletin of the Faculty of Engineering. Mansoura University
Verified
Journal Article
Open access
PDF file
RMReham H. Mohammed
Reham H. Mohammed
FBF. Bendary
F. Bendary
KEK. Elserafi
K. Elserafi
AGA. Ghanem
A. Ghanem
MSM. Soliman
M. Soliman
In this article a three non-model based trajectory tracking controllers for rigid simple open chain robot manipulator are investigated. The first is a Fuzzy-PID controller, it is considered as a reference benchmark to compare its results with the others which are a proportional Derivative (PD) tuned using genetic algorithm (GA) and an Adaptive Neuro Fuzzy Inference System (ANFIS). The simulation is carried out for the first three joints of robot arm (PUMA560) aiming to track aquintic polynomial trajectory with minimum errors, and good disturbance rejection. Simulation results, shows that using Fuzzy-PID has better steady state error and RMS error than the ANFIS and PD tuned using GA. The three controllers are tested by simulated under the same conditions using SIMULINK under MATLAB2013a.