1 June 2008 in Investigative Ophthalmology & Visual Science
Purpose. To assess the variation in macular thickness measurements in healthy Caucasian and African American men and women through Stratus OCT optical coherence tomography (OCT-3). methods. One hundred sixty-six eyes of 83 healthy patients underwent complete ophthalmologic examination in this prospective study. Exclusion criteria included a diagnosis of diabetes mellitus, hypertension, intraocular pressure (IOP) greater than 21 mm Hg, history of eye surgery or trauma, or evidence of eye disease. For analysis purposes, the authors excluded those participants in whom OCT signal strength was <7 in each eye. A fast macular thickness protocol consisting of a 6-mm radial scan centered on the fovea was used for the analysis, and the data were analyzed using the t-test for independence and linear regression. Both eyes of each patient were analyzed using the OCT-3, and analysis showed a statistically significant correlation between right and left eyes. Therefore, only one eye from each patient was randomly selected for final correlation and analysis. results. Mean foveal thickness (MFT) for Caucasians was 32 μm greater than for African Americans (217 vs. 185 μm, respectively; P < 0.001). The MFT was significantly thicker in males than in females (220 vs. 197 μm, respectively; P < 0.001). conclusions. The fovea is significantly less thick in African Americans and females than in Caucasians and males. Racial and sexual differences should be considered when interpreting an OCT scan.
1 April 2006 in Journal of American Association for Pediatric Ophthalmology and Strabismus
1 September 2003 in Journal of Cataract & Refractive Surgery
A survey of pediatric cataract surgery and intraocular lens (IOL) implantation practice patterns of adult and pediatric cataract surgeons was performed in October 2001. Questionnaires were distributed to the American Society of Cataract and Refractive Surgery and the American Association for Pediatric Ophthalmology and Strabismus. The overall return rate was 12.6% and 41.0%, respectively. Results show that pediatric cataract surgery with IOL implantation is being performed at a younger age than 8 years ago. Also, pediatric cataract surgery practice patterns are evolving in step with advances in adult surgery but with notable differences.
1 January 2011 in Journal of Cataract & Refractive Surgery
Management of the posterior capsule significantly affects the outcome of pediatric cataract surgery. Posterior capsule opacification (PCO) is rapid and virtually inevitable in very young children when adult-style cataract surgery is performed and the posterior capsule is left intact. In eyes with pediatric cataract, primary posterior capsulotomy and vitrectomy are considered routine surgical steps, especially in younger children. The site of intraocular lens (IOL) fixation and the surgical technique used also affect the prevalence of PCO. The present systematic review evaluates the options available to prevent PCO or ensure a clear central visual axis after pediatric cataract surgery. Newer approaches to posterior capsule management such as pars plicata posterior capsulorhexis, sutureless vitrectomy, sealed-capsule irrigation, and bag-in-the-lens IOL are discussed. Management of the posterior capsule in the presence of a preexisting posterior capsule defect and posterior capsule plaque and options to treat PCO are also reviewed. No author has a financial or proprietary interest in any material or method mentioned.
1 September 2004 in Journal of Cataract & Refractive Surgery
To obtain measurements of the white-to-white distance and the anterior chamber and ciliary sulcus diameters in phakic human eyes obtained post-mortem to find a correlation between these measurements. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Twenty-two phakic human eyes obtained from eye banks within 24 hours of death were evaluated. The following measurements were performed: white-to-white distance, anterior chamber diameter with a plastic sizer after a small limbal incision, and anterior chamber and ciliary sulcus diameters after fixation and sagittal section of the eyes. The first 10 eyes were studied at the 6 o'clock to 12 o'clock meridian and the last 12 eyes, at the 3 o'clock to 9 o'clock meridian. A positive correlation was found between the white-to-white measurements and the anterior chamber diameter in the 10 eyes studied at the 6 o'clock to 12 o'clock meridian but not in the 12 eyes studied at the 3 o'clock to 9 o'clock meridian. The latter is the meridian frequently used by surgeons to perform white-to-white measurements and thus choose the overall size of the phakic intraocular lens to be implanted. No correlation was found between the white-to-white measurements and the ciliary sulcus diameter in the 2 meridians. Experimental studies using cadaver eyes are helpful in evaluating sizing techniques for phakic IOL implantation as well as in better understanding the anatomical relationships between ocular structures.
1 December 2014 in Journal of American Association for Pediatric Ophthalmology and Strabismus