Salina Abdul Samad

Salina Abdul Samad

Auto-generated profile, based on publicly available information

Salina Abdul Samad

Department of Electrical, Electronics and Systems Engineering, Universiti Kebangsaan Malaysia, 43600Bangi, Malaysia

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2014 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MHM A Hannan
M A Hannan
Saad MutasharSaad Mutashar
Saad Mutashar
SSSalina A Samad
Salina A Samad
AHAini Hussain
Aini Hussain
The development of implanted devices is essential because of their direct effect on the lives and safety of humanity. This paper presents the current issues and challenges related to all methods used to harvest energy for implantable biomedical devices. The advantages, disadvantages, and future trends of each method are discussed. The concept of harvesting energy from environmental sources and human body motion for implantable devices has gained a new relevance. In this review, the harvesting kinetic, electromagnetic, thermal and infrared radiant energies are discussed. Current issues and challenges related to the typical applications of these methods for energy harvesting are illustrated. Suggestions and discussion of the progress of research on implantable devices are also provided. This review is expected to increase research efforts to develop the battery-less implantable devices with reduced over hole size, low power, high efficiency, high data rate, and improved reliability and feasibility. Based on current literature, we believe that the inductive coupling link is the suitable method to be used to power the battery-less devices. Therefore, in this study, the power efficiency of the inductive coupling method is validated by MATLAB based on suggested values. By further researching and improvements, in the future the implantable and portable medical devices are expected to be free of batteries.

28 December 2011 in Sensors
Verified
Journal Article
Open access
PDF file
MHM A Hannan
M A Hannan
Saad MutasharSaad Mutashar
Saad Mutashar
SSSalina A. Samad
Salina A. Samad
AHAini Hussain
Aini Hussain
Implanted medical devices are very important electronic devices because of their usefulness in monitoring and diagnosis, safety and comfort for patients. Since 1950s, remarkable efforts have been undertaken for the development of bio-medical implanted and wireless telemetry bio-devices. Issues such as design of suitable modulation methods, use of power and monitoring devices, transfer energy from external to internal parts with high efficiency and high data rates and low power consumption all play an important role in the development of implantable devices. This paper provides a comprehensive survey on various modulation and demodulation techniques such as amplitude shift keying (ASK), frequency shift keying (FSK) and phase shift keying (PSK) of the existing wireless implanted devices. The details of specifications, including carrier frequency, CMOS size, data rate, power consumption and supply, chip area and application of the various modulation schemes of the implanted devices are investigated and summarized in the tables along with the corresponding key references. Current challenges and problems of the typical modulation applications of these technologies are illustrated with a brief suggestions and discussion for the progress of implanted device research in the future. It is observed that the prime requisites for the good quality of the implanted devices and their reliability are the energy transformation, data rate, CMOS size, power consumption and operation frequency. This review will hopefully lead to increasing efforts towards the development of low powered, high efficient, high data rate and reliable implanted devices.

1 January 2004
Verified
Conference Paper
Closed access
AMA.M. Muad
A.M. Muad
AHA. Hussain
A. Hussain
SSS.A. Samad
S.A. Samad
MMM.M. Mustaffa
M.M. Mustaffa
BMB.Y. Majlis
B.Y. Majlis
Vision based automatic lane tracking system requires information such as lane markings, road curvature and leading vehicle be detected before capturing the next image frame. Placing a camera on the vehicle dashboard and capturing the forward view results in a perspective view of the road image. The perspective view of the captured image somehow distorts the actual shape of the road, which involves the width, height, and depth. Respectively, these parameters represent the x, y and z components. As such, the image needs to go through a pre-processing stage to remedy the distortion using a transformation technique known as an inverse perspective mapping (IPM). This paper outlines the procedures involved.

30 June 2014 in Sensors
Verified
Journal Article
Open access
PDF file
Saad MutasharSaad Mutashar
Saad Mutashar
MHM A Hannan
M A Hannan
SSSalina A. Samad
Salina A. Samad
AHAini Hussain
Aini Hussain
The use of wireless communication using inductive links to transfer data and power to implantable microsystems to stimulate and monitor nerves and muscles is increasing. This paper deals with the development of the theoretical analysis and optimization of an inductive link based on coupling and on spiral circular coil geometry. The coil dimensions offer 22 mm of mutual distance in air. However, at 6 mm of distance, the coils offer a power transmission efficiency of 80% in the optimum case and 73% in the worst case via low input impedance, whereas, transmission efficiency is 45% and 32%, respectively, via high input impedance. The simulations were performed in air and with two types of simulated human biological tissues such as dry and wet-skin using a depth of 6 mm. The performance results expound that the combined magnitude of the electric field components surrounding the external coil is approximately 98% of that in air, and for an internal coil, it is approximately 50%, respectively. It can be seen that the gain surrounding coils is almost constant and confirms the omnidirectional pattern associated with such loop antennas which reduces the effect of non-alignment between the two coils. The results also show that the specific absorption rate (SAR) and power loss within the tissue are lower than that of the standard level. Thus, the tissue will not be damaged anymore.

17 November 2015 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
Safat Bin WaliSafat Bin Wali
Safat Bin Wali
MHM A Hannan
M A Hannan
AHAini Hussain
Aini Hussain
SSSalina A. Samad
Salina A. Samad
The main objective of this study is to develop an efficient TSDR system which contains an enriched dataset of Malaysian traffic signs. The developed technique is invariant in variable lighting, rotation, translation, and viewing angle and has a low computational time with low false positive rate. The development of the system has three working stages: image preprocessing, detection, and recognition. The system demonstration using a RGB colour segmentation and shape matching followed by support vector machine (SVM) classifier led to promising results with respect to the accuracy of 95.71%, false positive rate (0.9%), and processing time (0.43 s). The area under the receiver operating characteristic (ROC) curves was introduced to statistically evaluate the recognition performance. The accuracy of the developed system is relatively high and the computational time is relatively low which will be helpful for classifying traffic signs especially on high ways around Malaysia. The low false positive rate will increase the system stability and reliability on real-time application.

17 June 2011 in Sensors
Verified
Journal Article
Open access
PDF file
MMMazlina Mamat
Mazlina Mamat
SSSalina Abdul Samad
Salina Abdul Samad
MHM A Hannan
M A Hannan
This paper reports the design of an electronic nose (E-nose) prototype for reliable measurement and correct classification of beverages. The prototype was developed and fabricated in the laboratory using commercially available metal oxide gas sensors and a temperature sensor. The repeatability, reproducibility and discriminative ability of the developed E-nose prototype were tested on odors emanating from different beverages such as blackcurrant juice, mango juice and orange juice, respectively. Repeated measurements of three beverages showed very high correlation (r > 0.97) between the same beverages to verify the repeatability. The prototype also produced highly correlated patterns (r > 0.97) in the measurement of beverages using different sensor batches to verify its reproducibility. The E-nose prototype also possessed good discriminative ability whereby it was able to produce different patterns for different beverages, different milk heat treatments (ultra high temperature, pasteurization) and fresh and spoiled milks. The discriminative ability of the E-nose was evaluated using Principal Component Analysis and a Multi Layer Perception Neural Network, with both methods showing good classification results.