Paola Scarparo

Paola Scarparo

Auto-generated profile, based on publicly available information

Paola Scarparo

Department of Interventional Cardiology Thoraxcenter, Erasmus University Medical Centre Rotterdam The Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
RIRiccardo Improta
Riccardo Improta
PSPaola Scarparo
Paola Scarparo
JWJeroen Wilschut
Jeroen Wilschut
QWQuinten Wolff
Quinten Wolff
JDJoost Daemen
Joost Daemen
RDRoberto Diletti
Roberto Diletti
Objectives: To compare stent recoil (SR) of the thin‐strut durable‐polymer Zotarolimus‐eluting stent (dp‐ZES) and the ultrathin‐strut bioabsorbable‐polymer Sirolimus‐eluting stent (bp‐SES) in chronic total occlusions (CTOs) and to investigate the predictors of high SR in CTOs.Background: Newer ultrathin drug eluting stent might be associated with lower radial force and higher elastic recoil due to the thinner strut design, possibly impacting on the rate of in‐stent restenosis and thrombosis.Methods: Between January 2017 and November 2019, consecutive patients with CTOs undergoing percutaneous coronary intervention were evaluated. Only patients treated with dp‐ZES or bp‐SES were included and stratified accordingly. Quantitative coronary angiography analysis was used to assess absolute SR, relative SR, absolute focal SR, relative focal SR, high absolute, and high relative focal SR.Results: A total of 128 lesions (67 treated with dp‐ZES and 61 with bp‐SES) in 123 patients were analyzed. Between bp‐SES and dp‐ZES no differences were found in absolute SR (p = .188), relative SR (p = .138), absolute focal SR (p = .069), and relative focal SR (p = .064). High absolute and high relative focal SR occurred more frequently in bp‐SES than in dp‐ZES (p = .004 and p = .015). Bp‐SES was a predictor of high absolute focal SR (Odds ratio [OR] 3.29, 95% confidence interval [CI] 1.50–7.22, p = .003]. High‐pressure postdilation and bp‐SES were predictors of high relative focal SR (OR 2.22, 95% CI 1.01–4.86, p = .047; OR 2.74, 95% CI 1.24–6.02, p = .012, respectively).Conclusions: Both stents showed an overall low SR. However, ultra‐thin strut bp‐SES was a predictor of high absolute and high relative focal SR.

1 November 2021 in Journal of Invasive Cardiology
Verified
Journal Article
Closed access
PSPaola Scarparo
Paola Scarparo
MGMenno van Gameren
Menno van Gameren
JWJeroen Wilschut
Jeroen Wilschut
JDJoost Daemon
Joost Daemon
WDWijnand K. Den Dekker
Wijnand K. Den Dekker
RDRoberto Diletti
Roberto Diletti
We compared very long-term clinical outcomes in STEMI patients with either large or small thrombus burden. Original Contribution from Journal of Invasive Cardiology. mortality ST-segment elevation myocardial infarction thrombus burden

1 June 2020 in Canadian Journal of Cardiology
Verified
Journal Article
Closed access
PSPaola Scarparo
Paola Scarparo
JWJeroen Wilschut
Jeroen Wilschut
NMNicolas M. Van Mieghem
Nicolas M. Van Mieghem
RDRoberto Diletti
Roberto Diletti

27 July 2026 in JACC: Cardiovascular Interventions
Verified
Journal Article
Open access
PSPaola Scarparo
Paola Scarparo
PAPierfrancesco Agostoni
Pierfrancesco Agostoni
OGOmer Goktekin
Omer Goktekin
CMCarlo Di Mario
Carlo Di Mario
AAAlexandre Avran
Alexandre Avran
RDRoberto Diletti
Roberto Diletti

1 August 2023 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
PSPaola Scarparo
Paola Scarparo
TSThom Schermers
Thom Schermers
RIRiccardo Improta
Riccardo Improta
IKIsabella Kardys
Isabella Kardys
JWJeroen Wilschut
Jeroen Wilschut
RDRoberto Diletti
Roberto Diletti
Objectives: To evaluate the stent expansion of the durable‐polymer Zotarolimus‐eluting stent (dp‐ZES), the durable‐polymer Everolimus‐eluting stent (dp‐EES), and the bioabsorbable‐polymer Sirolimus‐eluting stent (bp‐SES) in calcified coronary chronic total occlusions (CTO).Background: The newer generation stents with ultrathin struts might raise concerns regarding reduced radial strength and higher stent recoil (SR) when implanted in calcified CTOs.Methods: Between January 2017 and June 2021 consecutive patients with CTO undergoing percutaneous coronary intervention with dp‐ZES, dp‐EES, or bp‐SES were evaluated. The analysis was performed in calcific and in noncalcific CTOs. Quantitative coronary angiography analysis was used to assess diameter stenosis (DS), absolute and relative SR, absolute and relative focal SR, absolute and relative balloon deficit (BD), and absolute and relative focal BD. The primary endpoint was DS.Results: A total of 213 CTOs were evaluated, 115 calcific CTOs (dp‐ZES:25, dp‐EES:29, bp‐SES:61) and 98 non‐calcific CTOs (dp‐ZES:41, dp‐EES:11, bp‐SES:46). In calcific CTOs, residual DS was lower in dp‐ZES than in dp‐EES and bp‐SES (−1.00% [−6.50–6.50] vs. 13.00% [7.0–19.00] vs. 15.00% [5.00–20.00]; p < 0.001). Dp‐ZES was also an independent predictor of residual DS ≤ 10% (OR 11.34, 95% CI 2.6–49.43, p = 0.001). Absolute and relative focal SR and absolute and relative SR were similar between dp‐ZES, dp‐EES, and bp‐SES (p = 0.913, p = 0.890, p = 0.518, p = 0.426, respectively). In noncalcified CTOs, the residual DS was similar in the three groups (p = 0.340). High relative focal SR was less frequent in dp‐ZES than in dp‐EES and in bp‐SES (19.5% vs. 54.5% vs. 37.0%; p < 0.048).Conclusions: The three stent platforms demonstrated an overall low residual DS when implanted in CTOs. However, dp‐ZES was associated with the lowest residual DS and identified as independent predictor of residual DS ≤ 10% in patients with calcific CTOs. Dp‐ZES was associated with a lower incidence of high relative focal stent recoil, in noncalcific CTOs. Balloon deficit might be considerate as a surrogate for stent expansion in calcified CTOs.

2 November 2022 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
ASAlessandra Scoccia
Alessandra Scoccia
PSPaola Scarparo
Paola Scarparo
TNTara Neleman
Tara Neleman
HKHala Kakar
Hala Kakar
JWJeroen Wilschut
Jeroen Wilschut
RDRoberto Diletti
Roberto Diletti
Background Angiography-based vessel fractional flow reserve (vFFR) demonstrated a strong correlation with invasive fractional flow reserve (FFR) in both a pre- and post-percutaneous coronary intervention (PCI) setting. However, the role of vFFR and its correlation with post-PCI FFR in chronic coronary occlusions (CTO) has not been evaluated yet. We sought to investigate the diagnostic performance of post-PCI vFFR with post-PCI FFR as a reference in patients undergoing successful CTO PCI. Methods Between March 2016 and April 2020, a total of 80 patients from the FFR-SEARCH (prospective registry) and FFR REACT (randomized controlled trial) studies underwent successful CTO recanalization with post-PCI FFR measurements. Results A total of 50 patients (median age 66 (interquartile range [IQR]: 56-74) years, 76% were male) were eligible for the analysis. Median post-PCI FFR was 0.89 (IQR: 0.84-0.94), while median post-PCI vFFR was 0.91 (IQR: 0.85-0.94) (p 0.10). Suboptimal physiological results, defined as FFR and vFFR <0.90, were identified in 26 (52%) and in 21 (42%) patients, respectively. A strong correlation (r = 0.82) was found between vFFR and FFR with a mean bias of 0.013 +/- 0.051. Receiver-operating characteristics curve analysis revealed an excellent accuracy of vFFR in predicting FFR <0.90 (area under the curve: 0.97; 95% confidence interval: 0.93-1.00). Conclusion Post-PCI vFFR shows a good correlation with post-PCI FFR and a high diagnostic accuracy for post-PCI FFR <= 0.90 in patients undergoing successful PCI of a CTO lesion.