Yi Li

Yi Li

Auto-generated profile, based on publicly available information

Yi Li

National Measurement Institute, Lindfield, NSW, Australia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
IDImanka Jayathilaka Ranmanna Dewayalage
Imanka Jayathilaka Ranmanna Dewayalage
WYWei Yan
Wei Yan
FEFrederick S. Emms
Frederick S. Emms
IBIlya F. Budovsky
Ilya F. Budovsky
YLYi Li
Yi Li
Duane RobinsonDuane Robinson
Duane Robinson
Non-ideal frequency response and voltage non-linearity of high-voltage instrument transformers directly impact the accuracy of high-voltage measurements in the presence of harmonics. Characterization of voltage instrument transformer frequency response is generally performed at low voltage with sinusoidal test signals. Those results may not accurately represent the response of the instrument transformer when subjected to distorted waveforms in modern power systems. This paper presents a calibration system for the evaluation of harmonic measurement accuracy of single-phase instrument transformers with rated voltages up to 132/√3 kV using multi-tone test signals containing a high-voltage fundamental component and superimposed harmonics up to 10 kHz. Such signals would represent the realistic operating conditions of high-voltage instrument transformers. The performance of the developed system was analyzed by obtaining the voltage ratio and phase displacement of the reference capacitive voltage divider from 50 Hz to 10 kHz at 1 kV with an expanded uncertainty of 0.07% for the voltage ratio error and 0.09 crad for the phase error. The effect of voltage linearity at harmonic frequencies and the effect of the fundamental voltage on the errors of the measurements of harmonics were also evaluated. The results prove that the system is capable of calibrating high-voltage instrument transformers under distorted waveform conditions with an uncertainty of 0.13 % for ratio and 0.15 crad for phase error at harmonic frequencies from 100 Hz to 10 kHz, and 0.02 % and 0.04 crad at the fundamental power frequency of 50 Hz.

21 March 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
WYWei Yan
Wei Yan
WZWei Zhao
Wei Zhao
YLYi Li
Yi Li

17 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DDDongxue Dai
Dongxue Dai
YLYi Li
Yi Li
JWJiafu Wang
Jiafu Wang
FEFrederick Emms
Frederick Emms
HSHaiming Shao
Haiming Shao
NIM (National Institute of Metrology, China) and NMIA (National Measurement Institute, Australia) carried out a comparison program, which included low-voltage capacitance, the voltage dependence of high-voltage capacitance and the dielectric dissipation factor (DDF) at 50 Hz. The travelling standards included a low-voltage standard capacitor, a dissipation factor standard and a 100 kV compressed-gas capacitor. The capacitance and DDF of the standard capacitor, measured by the two institutes, agreed within 2 μF/F and 2×10 -6 , respectively, at 50 Hz and 500 V. DDF measurements at nominal values of 0.00000, 0.0001 and 0.001 agreed within 6×10 -6 at 50 Hz and 10 kV. The capacitance change of a 100 kV compressed-gas capacitor measured by the two institutes agreed within 2 μF/F over the voltage range from 10 kV to 100 kV. The success of the program proved comparisons using a re-filled high-voltage compressed gas capacitor and a low-voltage standard capacitor can be conveniently used to validate the complete traceability chain of the measurement of high-voltage capacitance at 50 Hz. The program also proved that DDF measurements with different implementations of traceability chain via capacitance and resistance would agree well within the uncertainties required by industrial measurements and a commercial DDF standard that has undergone international air travel would be sufficiently stable.