1 February 2020 in Analytica Chimica Acta
1 June 2018 in Biosensors and Bioelectronics
1 June 2016 in Materials Science and Engineering: C
28 March 2019 in Journal of the Electrochemical Society
Herein, a simple and selective electrochemical sensor was proposed for non-enzymatic determination of hydrogen peroxide (H2O2). This sensor was fabricated by incorporation of the novel nanostructured orthorhombic vanadium pentoxide (V2O5) into the carbon paste electrode (CPE) which provides significant catalytic activities for H2O2 reduction. The electrochemical impedance spectroscopy (EIS) studies illustrated lower charge transfer resistance (Rct) of the V2O5 modified CPE compared to the unmodified CPE. The effects of various experimental factors such as solution pH, applied potential and amount of modifier were studied in an amperometric mode. After optimization, the proposed method displayed a wide linear detection range from 5.0 to 1400.0 μM with a low detection limit of 2.5 μM based S/N = 3 and a response time less than 5 s. The sensitivity of 3.44 μA μM−1 cm−2 was acquired in the present method for H2O2 quantification is considerably better than other reported amperometric sensors with similar detection limits. In addition, the designed sensor depicted good reproducibility, remarkable selectivity, and excellent stability. The modified CPE was applicable for analysis of H2O2 in some cosmetic and personal care products.
1 March 2016 in Materials Science and Engineering: C
4 January 2020 in Journal of the Electrochemical Society
In this study, novel modifiers composed of multi walled carbon nanotubes (MWCNTs) and a series of noncyclic crown-type polyethers were prepared. The ligand loaded MWCNTs along with a room temperature ionic liquid (RTIL) 1-butyl-3-methylimidazolium hexafluoro phosphate ([bmim][PF 6 ]) were used for modification of a simple and low-cost carbon paste electrode (CPE). The modified CPE was employed for the determination of thallium(I) in aqueous medium using differential pulse anodic stripping voltammetry (DPASV) method. The effect of different experimental conditions such as supporting electrolyte, solution pH, accumulation potential, accumulation time, and modifier dosage were investigated and optimized. By DPASV, a linear dynamic range of 0.3–70 μ g l −1 was achieved. The detection limit (3S b ) was found to be 0.08 μ g l −1 , below the maximum allowable limit (2 μ g l −1 ) of the U.S. Environmental Protection Agency (USEPA). The present assay was also showed acceptable reproducibility with a relative standard deviation (RSD) value of 3.8% at 25.0 μ g l −1 level ( n = 7). The applicability of this electrode was successfully explored by measuring of thallium(I) in some natural waters without interference from sample matrix.