Stanislav Bondarenko

Stanislav Bondarenko

Auto-generated profile, based on publicly available information

Stanislav Bondarenko

Sytenko Institute of Spine and Joint Pathology National Academy of Medical Sciences of Ukraine, Kharkiv, Ukraine

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2018 in HIP International
Verified
Journal Article
Closed access
SBStanislav Bondarenko
Stanislav Bondarenko
NDNinel Dedukh
Ninel Dedukh
VFVolodymyr Filipenko
Volodymyr Filipenko
MAMandus Akonjom
Mandus Akonjom
ABAhmed Amine Badnaoui
Ahmed Amine Badnaoui
RSRan Schwarzkopf
Ran Schwarzkopf
Background: There is a lack of comparative data on osseointegration (BIC) of acetabular cup surfaces in hip arthroplasty in both normal bone mineral density and in conditions of osteoporosis. Aim: To compare osseointegration of acetabular implants with various types of surfaces in an animal model with normal and osteoporotic bone tissue. Material and Methods: The study was performed on 60 rats. To simulate osteoporosis ovariectomy was performed in 30 animals. Thirty healthy rats served as controls. In standardised defects of the distal metadiaphysis of the femur we implanted: porous tantalum Trabecular Metal (A), Trabecular Titanium (B), Titanium with Gription coating (C), Stiktite (D), and Tritanum (E). Bone apposition (osseointegration) was defined as all areas of direct “bone-to-implant contact” (BIC). Results: No qualitative morphological differences in the evaluation of BIC around different implant types was seen in normal rats and rats with osteoporosis. Connective tissue areas around implants were larger in rats with osteoporosis. Morphometric studies showed that the highest BIC were seen in implants A and B, both in healthy animals ([72.00 ± 3.48]% and [67.46 ± 1.69]%) and ones with osteoporosis ([59.19 ± 2.10]% and [53.36 ± 2.57]%). BIC was (60.10 ± 2.05)%, (60.26 ± 2.36)%, and (61.78 ± 2.27)% around implants C, D and E in healthy rats, respectively. BIC in osteoporosis was (45.39 ± 2.37)%, (47.81 ± 2.41)% and (42.10 ± 1.44)%, respectively. Conclusion: Our study showed that the evaluated implants have good BIC features. Furthermore, based on histomorthometry and histology, Porous tantalum Trabecular Metal (A) and Trabecular Titanium (B) implants exhibit higher BIC with bone tissue.

13 August 2017 in Regulatory Mechanisms in Biosystems
Verified
Journal Article
Open access
PDF file
SBS. E. Bondarenko
S. E. Bondarenko
MAM. Akonjom
M. Akonjom
VFV. A. Filipenko
V. A. Filipenko
DMD. V. Morozenko
D. V. Morozenko
ABA. Badnaoui
A. Badnaoui
KGK. V. Gliebova
K. V. Gliebova
The importance of biomarkers to predict recovery following total hip arthroplasty (THA) is still unclear to clinicians. To assess the preoperative biomarkers of patients with pseudoarthrosis of the femoral neck and their dynamics in the early postoperative period after THA, 50 patients aged 33 to 82 years old, 18 males and 32 females diagnosed with pseudoarthrosis of the femoral neck after failed internal fixation and failed conservative management were studied. The control group consisted of 30 healthy people aged 27 to 50 years, 13 males, 17 females. Patients’ blood was examined for biochemical markers upon admission, and then on the 7th and 14th days after surgery. Their blood serum content of total protein, albumin, glycoproteins, sialic acids, chondroitin sulfates, haptoglobin, glucose, cholesterol, triglycerides, ALT, AST, alkaline phosphatase, GGT, acid phosphatase, thymol index; interleukins (IL-1, IL-4 and IL-6.) and C-reactive protein was measured. The content of glycoproteins in the blood exceeded normal by 2.3 times, chondroitin sulfate by 4.7 times, sialic acids by 1.5 times, haptoglobin by 55.8%, fibrinogen by 19.1%, globulin by 19,6%, alkaline phosphatase activity by 72.3%, IL-1 by 94.7 and IL-6 by 3 times, C-reactive protein by 2.6 times. After THA there was a gradual decrease in blood biochemical and immunological markers. The most informative laboratory markers were glycoproteins, chondroitin sulfates, sialic acids, haptoglobin, activity of alkaline phosphatase, IL-1, IL-6 and IL-4, and C-reactive protein. Subsequent research is required to validate these dynamics.

18 September 2023 in World Journal of Orthopedics
Verified
Journal Article
Open access
SBStanislav Bondarenko
Stanislav Bondarenko
VFVolodymyr Filipenko
Volodymyr Filipenko
NANataliya Ashukina
Nataliya Ashukina
VMValentyna Maltseva
Valentyna Maltseva
GIGennadiy Ivanov
Gennadiy Ivanov
RSRan Schwarzkopf
Ran Schwarzkopf
The irrational and prolonged use of antibiotics in orthopaedic infections poses a major threat to the development of antimicrobial resistance. To combat antimicrobial resistance, researchers have implemented various novel and innovative modalities to curb infections. Nanotechnology involves doping ions/metals onto the scaffolds to reach the target site to eradicate the infective foci. In this connotation, we reviewed silver nanoparticle technology in terms of mechanism of action, clinical applications, toxicity, and regulatory guidelines to treat orthopaedic infections.

3 August 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
SBStanislav Bondarenko
Stanislav Bondarenko
NANataliya Ashukina
Nataliya Ashukina
VMValentyna Maltseva
Valentyna Maltseva
GIGennadiy Ivanov
Gennadiy Ivanov
ABAhmed Amine Badnaoui
Ahmed Amine Badnaoui
RSRan Schwarzkopf
Ran Schwarzkopf
Background: To compare structural features of the femoral bone of ovariectomized and non-ovariectomized rats after implantation of porous materials (TANTALUM, CONCELOC, TTM, ATLANT).Methods: Experiments were carried out on 56 white laboratory female rats aged 6 months. Rats were randomly assigned into groups: sham-operated control group (SH) or ovariectomy group (OVX). Four different commercial implant materials (TTM, CONCELOC, TANTALUM, ATLANT) were placed into the defects (diameter 2.5 mm, depth 3.0 mm) in the distal metaphysis of femurs. Rats were sacrificed 45 days after surgery. Histological study was performed and the percentage of the bone area (BA%) around the implant at a distance of 500 μm in the cancellous area was measured.Results: Formation of mature bone tissue of varying degrees around all of the implants was detected. In OVX rats cancellous bone defect zone was characterized by a high density of osteocytes on the surface. In the SH group, no differences in BA% among implant materials were found. In OVX rats, the BA% around ATLANT implants was 1.5-time less (p= 0.002) than around TANTALUM. The BA% around the rest of the materials was not statistically different.Conclusions: Bone formation around the studied porous titanium and tantalum materials in the osteoporosis model was lower than in normal bone. There were differences in bone formation around the different materials in the osteoporosis model, while in the normal bone model, these differences were absent.

18 April 2021 in World Journal of Orthopedics
Verified
Journal Article
Open access
SBStanislav Bondarenko
Stanislav Bondarenko
VFVolodymyr Filipenko
Volodymyr Filipenko
MKMichael Karpinsky
Michael Karpinsky
OKOlena Karpinska
Olena Karpinska
GIGennadiy Ivanov
Gennadiy Ivanov
RSRan Schwarzkopf
Ran Schwarzkopf
Osseointegration of porous titanium and tantalum implants in ovariectomized rabbits: A biomechanical study

27 March 2015 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
OTOlexiy Tyazhelov
Olexiy Tyazhelov
Volodymyr FilipenkoVolodymyr Filipenko
Volodymyr Filipenko
OYOleksandr Yaresko
Oleksandr Yaresko
SBStanislav Bondarenko
Stanislav Bondarenko
Recently for improving techniques of operations in orthopedics and traumatology they widely used mathematical modeling. Need of this presented work is due to the lack of studies of the stress-strain state (SSS) of pelvic bones in terms of modeling of the whole pelvic ring. Objective: using mathematical modeling to study the impact of SSS on separate parts of the pelvis. Methods: A geometric model of pelvis was developed at the biomechanical laboratory of the SI «Sytenko Institute of Spine and Joint Pathology National Academy of Medical Science of Ukraine», Kharkivbased on techniques for creating models by geometric sections obtained from tomographic images. There were taken into account some ties subjected tension while standing on one leg. The model was built in the program SolidWorks, and calculations were made using the program ANSYS. For evaluation of SSS Mises stresses were selected. For comparison of SSS there were studied three models of pelvic bones. Results: it was revealed that acetabulum and sacroiliac joint are the most strenuous parts for all models. When modeling the pubic symphysis it was found decreasing of the stress state in the front section of the acetabulum to 4.3 MPa (10.2 MPa for model A) and a slight increasing — 15.8 MPa (13.1 MPa for model A). For the model there was established rais­ing of SSS in front of the acetabulum (14.1 MPa) and decreasing (9.3 MPa) in the area of the sacroiliac joint in comparison with model A. Conclusion: The use of a comprehensive model of the pelvis with all its components makes it possible to accurately reflect SSS in comparison to previously used models and assess the impact of certain items of pelvic ring on SSS of its individual parts.