21 August 2025 in medRxiv
Previous TGIRT-seq analysis of RNAs in Inflammatory Breast Cancer (IBC) patient tumors, peripheral blood mononuclear cells (PBMCs) and plasma identified a short T-cell receptor mRNA fragment ( TRBJ1-6 ) as a potential IBC biomarker that was detected in plasma samples from IBC patients but not patients with non-inflammatory breast cancer or healthy donors. Here, we traced the origin of this TRBJ1-6 RNA fragment to IBC patient PBMCs and used a high-throughput RT-PCR/Cas12a assay with larger numbers of samples to confirm its prevalence in IBC patient PBMCs. Detection of this RNA was enhanced by T4 polynucleotide kinase treatment, indicating the presence of a 2’,3’-cyclic phosphate. Analysis of previous TGIRT-seq datasets revealed gene expression differences in IBC patient PBMCs that could contribute to TRBJ1-6 RNA prevalence in IBC patient PBMCs and plasma. Our results support the identification of the TRBJ1-6 RNA fragment as a novel, readily detectable blood-based RNA biomarker derived from IBC-patient immune cells, addressing a major unmet need for diagnosing IBC. Teaser: A novel type of blood-based biomarker for diagnosis of Inflammatory Breast Cancer
23 May 2026 in Surgical Innovation
Background: In minimally invasive surgery (MIS), maintaining consistent optical clarity is essential for surgical safety and efficiency. However, lens contamination events (LCEs) such as fogging and debris accumulation continue to disrupt visualization, requiring frequent camera removal and cleaning that prolongs operative time and is linked to surgical injuries. Objective: Determine performance of an artificial intelligence (AI) model, LUCID, for the detection of laparoscopic lens contamination. Methods: Surgical video footage was collected from the central Texas region and annotated to classify the lens state as “clean” or “dirty.” An AI model was trained on this dataset to detect lens contamination. 9 additional laparoscopic procedures were analyzed by the model and validated by human reviewers to determine true model performance. Results: Across the 9 cases analyzed by LUCID and validated by reviewers, the model achieved an overall accuracy of 90.42%, with a precision of 94.45%, sensitivity of 91.19%, and specificity of 88.80%, demonstrating potential for the use of LUCID to assess optical clarity in MIS. Conclusion: AI-enhanced visualization assessment presents a promising approach to enable objective detection of visual clarity in MIS. With compromised vision being a known problem with serious safety concerns, and future applications for AI-enhanced surgery requiring clear visualization for high performance, the importance of clear visualization is paramount more than ever before. Future work may look to standardize visual clarity across operative settings to mitigate variability in clinical outcomes.