Anna Lee

Anna Lee

Auto-generated profile, based on publicly available information

Anna Lee

Department of Anaesthesia and Intensive Care, Chinese University of Hong Kong, Shatin, Hong Kong

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 1995 in Anaesthesia and Intensive Care
Verified
Journal Article
Open access
PDF file
ALA. Lee
A. Lee
GBG. Bishop
G. Bishop
KHK. M. Hillman
K. M. Hillman
KDK. Daffurn
K. Daffurn
The concept of a Medical Emergency Team was developed in order to rapidly identify and manage seriously ill patients at risk of cardiopulmonary arrest and other high-risk conditions. The aim of this study was to describe the utilization and outcome of Medical Emergency Team interventions over a one-year period at a teaching hospital in South Western Sydney. Data was collected prospectively using a standardized form. Cardiopulmonary resuscitation occurred in 148/522 (28%) calls. Alerting the team using the specific condition criteria occurred in 253/522 (48%) calls and on physiological/pathological abnormality criteria in 121/522 (23%) calls. Survival rate to hospital discharge following cardiopulmonary arrest was low (29%), compared with other medical emergencies (76%).

1 November 2010 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
LCLester A. Critchley
Lester A. Critchley
ALAnna Lee
Anna Lee
AHAnthony M.-H. Ho
Anthony M.-H. Ho
Numerous cardiac output (CO) monitors have been produced that provide continuous rather than intermittent readings. Bland and Altman has become the standard method for validating their performance against older standards. However, the Bland and Altman method only assesses precision and does not assess how well a device detects serial changes in CO (trending ability). Currently, there is no consensus on how trending ability, or trend analysis, should be performed. Therefore, we performed a literature review to identify articles published between 1997 and 2009 that compared methods of continuous CO measurement. Identified articles were grouped according to measurement technique and statistical methodology. Articles that analyzed trending ability were reviewed with the aim of finding an acceptable statistical method. Two hundred two articles were identified. The most popular methods were pulse contour (69 articles), Doppler (54), bioimpedance (38), and transpulmonary or continuous thermodilution (27). Forty-one articles addressed trending, and of these only 23 provided an in-depth analysis. Several common statistical themes were identified: time plots, regression analysis, Bland and Altman using change in CO (ΔCO), and the 4-quadrant plot, which used direction of change of ΔCO to determine the concordance. This plot was further refined by exclusion of data when values were small. Receiver operating characteristic curves were used to define the exclusion zone. In animal studies, a reliable reference standard such as an aortic flowprobe was frequently used, and regression or time plots could be used to show trending. Clinical studies were more problematic because data collection points were fewer (8-10 per subject). The consensus was to use the 4-quadrant plot with exclusion zones and apply concordance analysis. A concordance rate of >92% when using a 15% zone indicated good trending. A new method of presenting trend data (ΔCO) on a polar plot is proposed. Agreement was shown by the angle with the horizontal axis and ΔCO by the distance from the center. Trending can be assessed by the vertical limits of the data, similar to the Bland and Altman method.

30 March 2020 in Anaesthesia
Verified
Journal Article
Closed access
PDF file
ACA. K. M. Chan
A. K. M. Chan
CNC. P. Nickson
C. P. Nickson
JRJ. W. Rudolph
J. W. Rudolph
ALA. Lee
A. Lee
GJGavin Matthew Joynt
Gavin Matthew Joynt

1 April 2002 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
ALAnna Lee
Anna Lee
WKWarwick D. Ngan Kee
Warwick D. Ngan Kee
TGTony Gin
Tony Gin
This quantitative systematic review compared the efficacy and safety of ephedrine with phenylephrine for the prevention and treatment of hypotension during spinal anesthesia for cesarean delivery. Seven randomized controlled trials (n = 292) were identified after a systematic search of electronic databases (MEDLINE, EMBASE, The Cochrane Controlled Trials Registry), published articles, and contact with authors. Outcomes assessed were maternal hypotension, hypertension and bradycardia, and neonatal umbilical cord blood pH values and Apgar scores. For the management (prevention and treatment) of maternal hypotension, there was no difference between phenylephrine and ephedrine (relative risk [RR] of 1.00; 95% confidence interval [CI], 0.96–1.06). Maternal bradycardia was more likely to occur with phenylephrine than with ephedrine (RR of 4.79; 95% CI, 1.47–15.60). Women given phenylephrine had neonates with higher umbilical arterial pH values than those given ephedrine (weighted mean difference of 0.03; 95% CI, 0.02–0.04). There was no difference between the two vasopressors in the incidence of true fetal acidosis (umbilical arterial pH value of <7.2; RR of 0.78; 95% CI, 0.16–3.92) or Apgar score of <7 at 1 and 5 min. This systematic review does not support the traditional idea that ephedrine is the preferred choice for the management of maternal hypotension during spinal anesthesia for elective cesarean delivery in healthy, nonlaboring women.

1 June 2006 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
ALAnna Lee
Anna Lee
LFLawrence T. Y. Fan
Lawrence T. Y. Fan
TGTony Gin
Tony Gin
MKManoj K. Karmakar
Manoj K. Karmakar
WKWarwick D. Ngan Kee
Warwick D. Ngan Kee
The original and modified Mallampati tests are commonly used to predict the difficult airway, but there is controversy regarding their accuracy. We searched MEDLINE and other databases for prospective studies of patients undergoing general anesthesia in which the results of a preoperative Mallampati test were compared with the subsequent rate of difficult airway (difficult laryngoscopy, difficult intubation, or difficult ventilation as reference tests). Forty-two studies enrolling 34,513 patients were included. The definitions of the reference tests varied widely. For predicting difficult laryngoscopy, both versions of the Mallampati test had good accuracy (area under the summary receiver operating characteristic (sROC) curve = 0.89 +/- 0.05 and 0.78 +/- 0.05, respectively). For predicting difficult intubation, the modified Mallampati test had good accuracy (area under the sROC curve = 0.83 +/- 0.03) whereas the original Mallampati test was poor (area under the sROC curve = 0.58 +/- 0.12). The Mallampati tests were poor at identifying difficult mask ventilation. Publication bias was not detected. Used alone, the Mallampati tests have limited accuracy for predicting the difficult airway and thus are not useful screening tests.

1 November 2001 in Annals of Emergency Medicine
Verified
Journal Article
Closed access
AGAlan Garner
Alan Garner
ALAnna Lee
Anna Lee
KHKen Harrison
Ken Harrison
CSCarl H. Schultz
Carl H. Schultz