This review focuses on blood pressure measurement techniques, algorithms, validation standards and recent sensors and technologies to measure arterial pulse.
In the present global context, continuous blood pressure (BP) monitoring is paramount in addressing the global mortality rates attributed to hypertension. Achieving precise insights into the human cardiovascular system necessitates accurate measurement of BP, and the accuracy depends on the faithful recording of oscillations or pulsations. This task ultimately depends on the caliber of the pressure sensor embedded in the BP device. In this context, we have fabricated a flexible resistive pressure sensor based on reduced graphene oxide (rGO) and a polydimethylsiloxane (PDMS) sponge that is highly flexible and sensitive. The designed device operates effectively with a minimal bias voltage of 500 mV, at which point it showed its maximum relative change in current, reaching approximately 25%. Additionally, the sensing device showed a notable change in resistance values, exhibiting almost 100% change in resistance when subjected to a pressure of 400 mmHg and high sensitivity of 0.27 mmHg–1. After promising outcomes were obtained during static pressure measurement, the sensor was used for BP monitoring in humans. The sensor accurately traced the oscillometric waveform (OMW) for distinct systolic blood pressure (SBP) and diastolic blood pressure (DBP) combinations to cover a range of medical situations, including hypotension, standard or normal, and hypertension. The values of SBP, DBP, and MAP were derived from the sensor’s output using the MAA technique, and the errors in these values concerning the simulator and the traditional BP monitor follow the universal AAMI/ESH/ISO protocols. Bland-Altman (B&A) correlation and scatter plots were used to compare the sensor’s results and further validate the proposed sensor. The sensor showed the mean and standard deviation error in the SBP, DBP, and MBP of −0.2 ± 5.9, −0.5 ± 7, and −0.9 ± 4.7 mmHg when compared with the noninvasive blood pressure (NIBP) simulator. The pulse rate (PR) was also calculated from the same OMW for the specified value of 80 beats per minute (bpm) given by the simulator and reported a mean PR value of ∼81 bpm, close to the reference value. The findings show that the flexible resistive sensing device can accurately measure BP and replace the existing sensors of BP devices.
In recent times, the high demand for flexible and wearable pressure sensors to monitor human health, particularly for patients afflicted with hypertension or high blood pressure (BP), has captured the keen interest of researchers. Capacitance-based flexible sensing devices offer real-time metrics regarding vital physiological parameters of the human body, such as BP and pulse rate (PR), thereby enabling the identification of cardiovascular complications. In this regard, we have developed a capacitive pressure sensor using polydimethylsiloxane (PDMS) and deionized water (DIW) and improved its key parameters by adding baking powder to PDMS-DIW. The sensor demonstrated excellent performance in static pressure measurements with a sensitivity of 0.021 Pa−1, detection limit of 1 Pa, and response time of 100 ms. We further investigated its application in human BP monitoring. The sensor successfully captured the oscillometric waveform (OMW) for all 160 participants and demonstrated excellent performance in accurately measuring BP, meeting all criteria outlined as the universal standard when compared with the reference devices: OMRON BP device and the gold-standard mercury-based sphygmomanometer. Furthermore, the sensor accurately provided the PR and agreed well with the reference BP device. Therefore, the developed BP sensor can be a viable alternative to replace the pressure sensors in existing BP devices.