Qi Yu

Qi Yu

Auto-generated profile, based on publicly available information

Qi Yu

State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LTLingwen Tan
Lingwen Tan
XWXiangyuan Wang
Xiangyuan Wang
QYQi Yu
Qi Yu
BYBocheng Yu
Bocheng Yu
MYMeng Yixuan
Meng Yixuan
Zhu LiMinZhu LiMin
Zhu LiMin
An electromagnetic-piezoelectric hybrid actuated nanopositioner for atomic force microscopy (AFM) is proposed. Applying the hybrid serial-parallel-kinetic design, the parallel xy -stage is actuated by the normal-stressed electromagnetic actuators to conduct planar scanning in a large scope. The z -axis is serially carried by the xy -stage and is actuated by a piezoelectric actuator (PEA) to track the sample’s topography with high speed. Moreover, a novel flexure mechanism is proposed for motion guidance and decoupling of the xy -stage, featuring the higher resonant frequency along the x -axis to satisfy the requirement of a faster planar axis in AFM imaging. The analytical model of the nanopositioner is established to optimally determine the parameters, and the results are verified by finite-element analysis. A prototype is fabricated and tested. Experimental results demonstrate that the triaxial strokes of 94.4 μm (x-axis), 102.8 μm ( y -axis), and 5.22 μm ( z -axis) are achieved, and the resonant frequencies are identified as 735 Hz ( x -axis), 650 Hz ( y -axis), and 6340 Hz ( z -axis), respectively. The implemented feedback controllers ensure the accuracy of high-speed trajectory tracking. Finally, the AFM imaging based on the proposed nanopositioner is conducted, confirming its effectiveness for large-scope and high-rate AFM imaging.

18 June 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XWXiangyuan Wang
Xiangyuan Wang
BYBocheng Yu
Bocheng Yu
LTLingwen Tan
Lingwen Tan
MYMeng Yixuan
Meng Yixuan
QYQi Yu
Qi Yu
Zhu LiMinZhu LiMin
Zhu LiMin
High-throughput raster scanning enables high-rate atomic force microscopy (AFM) imaging in a large area. This article proposes a novel serial-kinematic tri-axial AFM scanner to meet the different stroke and bandwidth requirements of each axis in AFM raster scanning. By means of hybrid actuation, this scanner combines the high-force-density and long-range merits of the normal-stressed electromagnetic actuator (NSEA) and the high-resonant-frequency advantage of the piezoelectric actuator (PEA). The X - and Y -stages are actuated by the self-developed NSEAs. Specifically, the X -axial moving mass is minimized by elaborately designing the serial kinematics and the flexure-internal structure. Thus, a high resonant frequency of 1313.2 Hz is achieved along the X -axis while realizing a 212.7 $\mu$ m stroke. The Y -stage is designed with a large moving platform. Thus, it can carry the entire XZ -stage to conduct the long-range Y -axial scanning. As for the Z -stage, a PEA is adopted as the actuator to track the surface topography at a high rate. The advancement of the proposed scanner is demonstrated in AFM imaging. Excellent results in both the large-area coarse scanning and the high-speed, high-resolution fine scanning reveal the strong nanopositioning capability of this development.

2 June 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XWXiangyuan Wang
Xiangyuan Wang
LTLingwen Tan
Lingwen Tan
QYQi Yu
Qi Yu
HWHao Wu
Hao Wu
MYMeng Yixuan
Meng Yixuan
Zhu LiMinZhu LiMin
Zhu LiMin
Achieving high-throughput uniform scanning of stick-slip actuators is challenging because the conventional sharp triangular trajectory can easily induce dynamic friction between the compliant mechanism and the end-effector, which can lead to scanning failures. To address these issues, this article proposes a smooth trajectory that integrates a linear rising edge for uniform sampling with a cubic B-spline curve for smooth transitions. By optimizing the parameters, the trajectory effectively minimizes peak acceleration and reduces high-frequency components, thereby enhancing both scanning throughput and accuracy. The experimental results demonstrated that the proposed trajectory yielded a scanning throughput 2.86 times greater than that achieved with the conventional triangular trajectory. Moreover, the proposed trajectory demonstrated superior accuracy in scanning across all tested frequencies. This advancement is significant for expanding the applications of stick-slip actuators in high-throughput scenarios.

1 April 2026 in Review of Scientific Instruments
Verified
Journal Article
Closed access
QYQi Yu
Qi Yu
HWHao Wu
Hao Wu
ZHZhiHan Hong
ZhiHan Hong
XWXiangYuan Wang
XiangYuan Wang
Zhu LiMinZhu LiMin
Zhu LiMin
The achievable performance of the complementary-filter-based parallel control for a compound dual-stage nano-positioning system is limited by its model-based sequential design structure. This study proposes a frequency-response-data-based optimization approach for the simultaneous and systematic design of the complementary-filter-based dual-feedback controller. The design procedure and corresponding Nyquist stability analysis are presented in detail. By directly utilizing frequency response data, the proposed method mitigates the effects of system identification errors. The controller design objective is formulated as a constrained optimization problem to achieve a flat amplitude frequency response with high control bandwidth. Comparative experiments conducted on a dual-stage nano-positioning system verify the effectiveness of the proposed approach. The proposed method reduces the root-mean-square tracking error from 70.6 nm using the baseline integral controller to 21.3 nm at 50 Hz sinusoidal tracking, demonstrating its clear superiority.

6 July 2025 in Precision Engineering
Verified
Journal Article
Closed access
QYQi Yu
Qi Yu
YMYixuan Meng
Yixuan Meng
XWXiangyuan Wang
Xiangyuan Wang
LTLingwen Tan
Lingwen Tan
LZLimin Zhu
Limin Zhu