Heidarali Shayanfar

Heidarali Shayanfar

Auto-generated profile, based on publicly available information

Heidarali Shayanfar

Center of Excellence for Power Systems Automation and Operation School of Electrical Engineering Iran University of Science and Technology Tehran Iran

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2022 in Applied Energy
Verified
Journal Article
Closed access
Mehdi MehdinejadMehdi Mehdinejad
Mehdi Mehdinejad
HSHeidarali Shayanfar
Heidarali Shayanfar
BMBehnam Mohammadi-Ivatloo
Behnam Mohammadi-Ivatloo

13 May 2013 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MEMasoud Esmaili
Masoud Esmaili
KGKiarash Gharani
Kiarash Gharani
HSHeidar Ali Shayanfar
Heidar Ali Shayanfar
Phasor measurement units (PMUs) have made it possible to observe and control wide-area power systems. In this paper, a new redundant observability method as a mixed-integer linear programming (MILP) is presented for optimal PMU placement. Redundant observation of buses enhances measurement reliability. The proposed method improves observability redundancy by a new objective function while using the same number of PMUs as the existing methods. Because of using MILP, the global optimal integer solution is achieved with a zero optimality gap. In addition, a systematic novel approach is proposed to incorporate already installed branch flow measurements in the PMU placement problem leading to a reduced number of PMUs required for system observability. This approach is able to handle both single and multiple flow measurements incident to a bus. PMU placement in case of PMU failure or branch outage is also studied. The proposed method along with an existing method is tested on four IEEE and Polish 3375-bus test systems. Obtained results, discussed in detail, show the efficiency of the proposed method in both speed and accuracy.

8 January 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
KHKazem Haghdar
Kazem Haghdar
HSHeidar Ali Shayanfar
Heidar Ali Shayanfar
This paper presents the computation of optimal DC sources and switching angles using the Generalized Pattern Search (GPS) optimization method for harmonic elimination in a cascaded MultiLevel Inverter (MLI). The goal is to solve nonlinear equations for eliminating low-order harmonics and reaching desired fundamental component. For case study 5 and 7-level inverter are chosen. The 7-level inverter with equal DC sources and 5 and 7-level inverter with an optimal DC source are applied to eliminate 5th and 7th harmonics. To obtain this goal, MATLAB software is used. Considering simulation results, cost and simpler implementation, 5-level inverter with an optimized DC source is more effective in all modulation indexes in comparison with 7-level inverter. Also, results demonstrate the superiority of GPS over Genetic Algorithm (GA) in attaining accurate global minima. For better evaluation of optimizing more DC sources and GPS performance in comparison with GA, 7-level inverter with two optimal DC sources is applied to eliminate 5th, 7th, 11th, and 13th harmonics. Finally, to validate the accuracy of the 5-level inverter with an optimal DC source and GPS performance, the experimental results are provided for a 5-level cascaded H-bridge inverter.


15 February 2022 in IEEE Access
Verified
Journal Article
Open access
Mehdi MehdinejadMehdi Mehdinejad
Mehdi Mehdinejad
HSHeidar Ali Shayanfar
Heidar Ali Shayanfar
Behnam Mohammadi-IvatlooBehnam Mohammadi-Ivatloo
Behnam Mohammadi-Ivatloo
HNHamed Nafisi
Hamed Nafisi
In this paper, a fully decentralized local energy market based on peer-to-peer(P2P) trading is proposed for small-scale prosumers. In the proposed market, the prosumers are classified as buyers and sellers and can bilaterally engage in energy trading (P2P) with each other. The buyer prosumers are equipped with electrical storage and can participate in a demand response (DR) program while protecting their privacy. In addition to bilateral negotiating with the local sellers, these players can compensate for their energy deficiency from the upstream market as the retail market at hours without local generation. In this paper, the retail market price is assumed uncertain. Robust optimization is applied to model this uncertainty in the buyer prosumers model. The proposed decentralized robust optimization guarantees the solution’s existence for each realization of uncertainty components. Furthermore, it performs optimization to realize the hard worse case from uncertainty components. A fully decentralized approach known as the fast alternating direction method of multipliers (FADMM) is employed to solve the proposed decentralized robust problem. The proposed approach does not require third-party involvement as a supervisory node nor disclose the players’ private information. Numerical studies were carried out on a small distribution system with several prosumers. The numerical results suggested the operationality and applicability of the proposed decentralized robust framework and the decentralized solving method.

4 February 2022 in Sustainable Cities and Society
Verified
Journal Article
Closed access
MSMohammad Seyfi
Mohammad Seyfi
Mehdi MehdinejadMehdi Mehdinejad
Mehdi Mehdinejad
BMBehnam Mohammadi-Ivatloo
Behnam Mohammadi-Ivatloo
HSHeidarali Shayanfar
Heidarali Shayanfar