Lucas Vatanabe Pazinato

Lucas Vatanabe Pazinato

Auto-generated profile, based on publicly available information

Lucas Vatanabe Pazinato

Interventional Radiology, Department of Radiology, University of São Paulo Medical School, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2022 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
TLTÚLIO LEITE
TÚLIO LEITE
LPLucas Vatanabe Pazinato
Lucas Vatanabe Pazinato
EBEdgar Bortolini
Edgar Bortolini
OPOsvaldo Ignacio Pereira
Osvaldo Ignacio Pereira
CNCesar Higa Nomura
Cesar Higa Nomura
JMJoaquim Mauricio Motta-Leal-Filho
Joaquim Mauricio Motta-Leal-Filho

1 January 2022 in Annals of Hepatology
Verified
Journal Article
Open access
MCMarlone Cunha-Silva
Marlone Cunha-Silva
FNFernando L. Ponte Neto
Fernando L. Ponte Neto
PAPriscila S. de Araújo
Priscila S. de Araújo
LPLucas V. Pazinato
Lucas V. Pazinato
RGRaquel D. Greca
Raquel D. Greca
DMDaniel F. Mazo
Daniel F. Mazo
The EncephalApp Stroop Test was developed to more easily diagnose minimal hepatic encephalopathy (MHE). A cut-off of >274.9sec (ONtime+OFFtime) reached a 78% sensitivity and 90% specificity in the validation study, but it has been poorly studied in Brazil. We aim to analyze the usefulness of this diagnostic method and to describe a cut-off value to screen MHE in Brazil. In this cross-sectional and single-center study, three positive psychometric tests defined the diagnosis of MHE as the gold standard. We evaluated gender, age, education, familiarity with smartphones, etiology of cirrhosis, Child-Pugh/MELD scores, and previous hepatic encephalopathy (HE). Healthy controls and patients without HE were compared for the task validation. The Chi-square and Mann-Whitney tests, logistic regression analysis, and ROC curves were used for statistical evaluation. We included 132 patients with cirrhosis (61% male) and 42 controls (62% male) around 51y. Sixty-three were diagnosed with MHE on psychometric tests and 23 had clinical HE. Viral hepatitis (38%) was the major etiology of cirrhosis. The median MELD was 10 and Child-Pugh A was more frequent (70%). There was no significant difference in test results between controls and patients without HE. There was also no influence of gender, age, education, and familiarity with smartphones in the test results. Child-Pugh A was associated with MHE (p=0.0106). A cut-off of >269.8sec (ONtime+OFFtime) had an 87% sensitivity and 77% specificity to detect MHE (p=0.002). This is a valid and reliable tool for screening MHE. However, optimal cut-off values need to be validated locally.

8 April 2021 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
LPLucas Vatanabe Pazinato
Lucas Vatanabe Pazinato
TLTulio Fabiano de Oliveira Leite
Tulio Fabiano de Oliveira Leite
EBEdgar Bortolini
Edgar Bortolini
OPOsvaldo Ignacio Pereira
Osvaldo Ignacio Pereira
CNCesar Higa Nomura
Cesar Higa Nomura
JMJoaquim Mauricio Motta-Leal-Filho
Joaquim Mauricio Motta-Leal-Filho
Background: Percutaneous retrieval of intravascular foreign bodies has recently increased as a treatment option. Purpose: To report our single-center experience of the percutaneous retrieval of 14 intravascular embolized catheter fragments in children and to conduct a literature review. Material and Methods: MEDLINE databases were searched for case reports and series including children and iatrogenic catheter fragments or guidewires retrieved through percutaneous techniques. We also conducted a retrospective analysis of 14 cases from our institution over a 14-year period. A total of 27 studies were selected comprising 74 children, plus our 14 unpublished cases. Statistical analyses were performed using Microsoft Excel version 2016. Results: Port catheter fragments and peripherally inserted central catheters (PICCs) were the most embolized foreign bodies and the pulmonary artery was the most common site of embolization in 44.1% of cases. Analysis of the retrieval technique demonstrated a preference for extraction through the femoral vein (81.7%) and using snare techniques (93.5%). The success rate of percutaneous retrieval was 96.6% with only 1.1% of procedure-related complications. Patients were asymptomatic in 77.2% of cases, presented septic complications in 2.3%, and no deaths were reported. Median fluoroscopy time was 10 min (range = 1.7–80 min) and median procedure length was 60 min (range = 35–208 min). Conclusion: Percutaneous retrieval of intravascular foreign bodies is a feasible, safe, and efficient technique in children and should be considered the preferred treatment option.

7 April 2022 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
LPLucas Vatanabe Pazinato
Lucas Vatanabe Pazinato
FUFelipe Shoiti Urakawa
Felipe Shoiti Urakawa
DSDaniel Takeshi Setuguti
Daniel Takeshi Setuguti
JMJoaquim Mauricio da Motta-Leal-Filho
Joaquim Mauricio da Motta-Leal-Filho
MMMarcos Roberto de Menezes
Marcos Roberto de Menezes

30 June 2021 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
TLTÚLIO LEITE
TÚLIO LEITE
LPLucas Vatanabe Pazinato
Lucas Vatanabe Pazinato
TNThiago Franchi Nunes
Thiago Franchi Nunes
JMJoaquim Mauricio Motta-Leal-Filho
Joaquim Mauricio Motta-Leal-Filho
Background: Pancreatic transplantation is a definitive treatment for selected patients with insulin-dependent diabetes. It is a technically challenging surgery, and vascular complications are the most common cause of pancreatic graft failure. Although rare, pancreas transplants present higher rates of pseudoaneurysms at the vascular anastomosis than other visceral transplants. We present a case of a simultaneous pancreas–kidney transplant complicated with graft failure and common iliac artery pseudoaneurysm that was successfully treated through endovascular techniques. Case presentation: A 34-year-old White woman presented with abdominal pain and a history of type 1 diabetes mellitus, end-stage renal disease, and two previous pancreas transplantation failures. The first was a simultaneous pancreas–kidney transplantation performed 7 months prior that was complicated by pancreas graft thrombosis within 1 month and required graft resection. Five months later, she underwent a second pancreas transplantation with another pancreatic graft thrombosis requiring graft resection. Abdominal angiotomography revealed a pseudoaneurysm in the right common iliac artery at the point of the previous graft anastomosis. The patient was successfully treated endovascularly with a covered stent in the common iliac artery. Conclusion: Stent graft implantation for the treatment of common iliac artery pseudoaneurysm as a complication of simultaneous pancreas–kidney transplantation is a safe and feasible procedure.

1 March 2023 in Brazilian Journal of Nephrology
Verified
Journal Article
Open access
TLTÚLIO LEITE
TÚLIO LEITE
LPLucas Vatanabe Pazinato
Lucas Vatanabe Pazinato
MVMaria Juliana de Aquino Vidal
Maria Juliana de Aquino Vidal
DFDanielo de Freitas
Danielo de Freitas
JMJoaquim Mauricio Motta-Leal-Filho
Joaquim Mauricio Motta-Leal-Filho
Tuberous sclerosis complex (TSC) and autosomal dominant polycystic kidney disease (ADPKD) are conditions related to renal failure that can rarely occur in association as a contiguous gene syndrome. Angiomyolipomas (AMLs) are renal tumors strongly related to TSC that may rupture and cause life-threatening bleedings. We present a patient with TSC, ADPKD, and renal AMLs with persistent hematuria requiring blood transfusion. The persistent hematuria was successfully treated through endovascular embolization, a minimally invasive nephron sparing technique.