Joachim Ernst Wildberger

Joachim Ernst Wildberger

Auto-generated profile, based on publicly available information

Joachim Ernst Wildberger

Department of Radiology & Nuclear Medicine, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2022 in Investigative Radiology
Verified
Journal Article
Open access
VMVictor Mergen
Victor Mergen
TSThomas Sartoretti
Thomas Sartoretti
MBMatthias Baer-Beck
Matthias Baer-Beck
BSBernhard Schmidt
Bernhard Schmidt
MPMartin Petersilka
Martin Petersilka
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Objectives: The aim of this study was to evaluate the feasibility and quality of ultra-high-resolution coronary computed tomography angiography (CCTA) with dual-source photon-counting detector CT (PCD-CT) in patients with a high coronary calcium load, including an analysis of the optimal reconstruction kernel and matrix size. Materials and Methods: In this institutional review board–approved study, 20 patients (6 women; mean age, 79 ± 10 years; mean body mass index, 25.6 ± 4.3 kg/m2) undergoing PCD-CCTA in the ultra-high-resolution mode were included. Ultra-high-resolution CCTA was acquired in an electrocardiography-gated dual-source spiral mode at a tube voltage of 120 kV and collimation of 120 × 0.2 mm. The field of view (FOV) and matrix sizes were adjusted to the resolution properties of the individual reconstruction kernels using a FOV of 200 × 200 mm2 or 150 × 150 mm2 and a matrix size of 512 × 512 pixels or 1024 × 1024 pixels, respectively. Images were reconstructed using vascular kernels of 8 sharpness levels (Bv40, Bv44, Bv56, Bv60, Bv64, Bv72, Bv80, and Bv89), using quantum iterative reconstruction (QIR) at a strength level of 4, and a slice thickness of 0.2 mm. Images with the Bv40 kernel, QIR at a strength level of 4, and a slice thickness of 0.6 mm served as the reference. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and blooming artifacts were quantified. For subjective image quality, 2 blinded readers evaluated image noise and delineation of coronary artery plaques and the adjacent vessel lumen using a 5-point discrete visual scale. A phantom scan served to characterize image noise texture by calculating the noise power spectrum for every reconstruction kernel. Results: Maximum spatial frequency (fpeak) gradually shifted to higher values for reconstructions with the Bv40 to Bv64 kernel (0.15 to 0.56 mm−1), but not for reconstructions with the Bv72 to Bv89 kernel. Ultra-high-resolution CCTA was feasible in all patients (median calcium score, 479). In patients, reconstructions with the Bv40 kernel and a slice thickness of 0.6 mm showed largest blooming artifacts (55.2% ± 9.8%) and lowest vessel sharpness (477.1 ± 73.6 ΔHU/mm) while achieving highest SNR (27.4 ± 5.6) and CNR (32.9 ± 6.6) and lowest noise (17.1 ± 2.2 HU). Considering reconstructions with a slice thickness of 0.2 mm, image noise, SNR, CNR, vessel sharpness, and blooming artifacts significantly differed across kernels (all P's < 0.001). With higher kernel sharpness, SNR and CNR continuously decreased, whereas image noise and vessel sharpness increased, with highest sharpness for the Bv89 kernel (2383.4 ± 787.1 ΔHU/mm). Blooming artifacts continuously decreased for reconstructions with the Bv40 (slice thickness, 0.2 mm; 52.8% ± 9.2%) to the Bv72 kernel (39.7% ± 9.1%). Subjective noise was perceived by both readers in agreement with the objective measurements. Considering delineation of coronary artery plaques and the adjacent vessel lumen, reconstructions with the Bv64 and Bv72 kernel (for both, median score of 5) were favored by the readers providing an excellent anatomic delineation of plaque characteristics and vessel lumen. Conclusions: Ultra-high-resolution CCTA with PCD-CT is feasible and enables the visualization of calcified coronaries with an excellent image quality, high sharpness, and reduced blooming. Coronary plaque characterization and delineation of the adjacent vessel lumen are possible with an optimal quality using Bv64 kernel, a FOV of 200 × 200 mm2, and a matrix size of 512 × 512 pixels.

10 February 2023 in British Journal of Radiology
Verified
Journal Article
Open access
TSThomas Sartoretti
Thomas Sartoretti
JWJoachim E Wildberger
Joachim E Wildberger
TFThomas Flohr
Thomas Flohr
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Since its development in the 1970s, X-ray CT has emerged as a landmark diagnostic imaging modality of modern medicine. Technological advances have been crucial to the success of CT imaging, as they have increasingly enabled improvements in image quality and diagnostic value at increasing radiation dose efficiency. With recent advances in engineering and physics, a novel technology has emerged with the potential to surpass several shortcomings and limitations of current CT systems. Photon-counting detector (PCD)-CT might substantially improve and expand the applicability of CT imaging by offering intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise and improved image contrast. In this review we sought to summarize the first clinical experience of PCD-CT. We focused on most recent prototype and first clinically approved PCD-CT systems thereby reviewing initial publications and presenting corresponding clinical cases.

1 March 2021 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
RHRobert J. Holtackers
Robert J. Holtackers
CHCaroline Van De Heyning
Caroline Van De Heyning
ACAmedeo Chiribiri
Amedeo Chiribiri
JWJoachim E. Wildberger
Joachim E. Wildberger
RBRene Botnar
Rene Botnar
MKM. Eline Kooi
M. Eline Kooi
For almost 20 years, late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been the reference standard for the non-invasive assessment of myocardial viability. Since the blood pool often appears equally bright as the enhanced scar regions, detection of subendocardial scar patterns can be challenging. Various novel LGE methods have been proposed that null or suppress the blood signal by employing additional magnetization preparation mechanisms. This review aims to provide a comprehensive overview of these dark-blood LGE methods, discussing the magnetization preparation schemes and findings in phantom, preclinical, and clinical studies. Finally, conclusions on the current evidence and limitations are drawn and new avenues for future research are discussed. Dark-blood LGE methods are a promising new tool for non-invasive assessment of myocardial viability. For a mainstream adoption of dark-blood LGE, however, clinical availability and ease of use are crucial.

1 January 2021 in BJR|Open
Verified
Journal Article
Open access
LNLidewij M.F.H. Neeter
Lidewij M.F.H. Neeter
HRH.P.J. (Frank) Raat
H.P.J. (Frank) Raat
RARodrigo Alcantara
Rodrigo Alcantara
QRQuirien Robbe
Quirien Robbe
MSMarjolein Smidt
Marjolein Smidt
MLMarc B.I. Lobbes
Marc B.I. Lobbes
Contrast-enhanced mammography (CEM) is a combination of standard mammography and iodinated contrast material administration. During the last decade, CEM has found its place in breast imaging protocols: after i.v. administration of iodinated contrast material, low-energy and high-energy images are retrieved in one acquisition using a dual-energy technique, and a recombined image is constructed enabling visualisation of areas of contrast uptake.The increased incorporation of CEM into everyday clinical practice is reflected in the installation of dedicated equipment worldwide, the (commercial) availability of systems from different vendors, the number of CEM examinations performed, and the number of scientific articles published on the subject. It follows that ever more radiologists will be confronted with this technique, and thus be required to keep up to date with the latest developments in the field. Most importantly, radiologists must have sufficient knowledge on how to interpret CEM images and be acquainted with common artefacts and pitfalls.This comprehensive review provides a practical overview of CEM technique, including CEM-guided biopsy; reading, interpretation and structured reporting of CEM images, including the accompanying learning curve, CEM artefacts and interpretation pitfalls; indications for CEM; disadvantages of CEM; and future developments.

1 February 2023 in British Journal of Radiology
Verified
Journal Article
Open access
PDF file
TSThomas Sartoretti
Thomas Sartoretti
MMMichael McDermott
Michael McDermott
VMVictor Mergen
Victor Mergen
AEAndré Euler
André Euler
BSBernhard Schmidt
Bernhard Schmidt
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
Objectives: To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA). Methods: CCTA with PCD-CT (prospective ECG-triggering, 120 kVp, automatic tube current modulation) was performed in a high-end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR-off) and with all quantum iterative reconstruction (QIR) levels (QIR-1 to 4). In the phantom, noise power spectrum, vessel attenuation, contrast-to-noise-ratio (CNR), and vessel sharpness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronary artery plaque delineation on 5-point Likert scales in patients. Results: In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR-4 to 40 keV QIR-off. Reconstructions at 40 keV QIR-4 exhibited the highest CNR (46.1 ± 1.8), vessel sharpness (425 ± 42 ∆HU/mm), and vessel attenuation (1098 ± 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR-3 and QIR-4 images received the best scores (p < 0.001). Conclusion: Forty keV VMI with QIR-4 significantly improved image quality of CCTA with PCD-CT. Advances in knowledge: PCD-CT at 40 keV and QIR-4 improves image quality of CCTA.

1 June 2016 in European Journal of Radiology
Verified
Journal Article
Closed access
MKMadeleine Kok
Madeleine Kok
CMCasper Mihl
Casper Mihl
BHBabs M.F. Hendriks
Babs M.F. Hendriks
SASibel Altintas
Sibel Altintas
BKBas L.J.H. Kietselaer
Bas L.J.H. Kietselaer
MDMarco Das
Marco Das