Xin Hui Ooi

Xin Hui Ooi

Auto-generated profile, based on publicly available information

Xin Hui Ooi

University of Michigan

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2026 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Open access
HMHamidreza Movahedi
Hamidreza Movahedi
XOXin Hui Ooi
Xin Hui Ooi
VTVivian V. Tran
Vivian V. Tran
WJWoongsun Jeon
Woongsun Jeon
JSJason Siegel
Jason Siegel
Anna StefanopoulouAnna Stefanopoulou
Anna Stefanopoulou
Detecting internal short circuits (ISCs) in a single cell connected in parallel with others is challenging because unmeasured internal currents can obscure measurable indicators such as charge loss and voltage drop from the faulty cell. In this work, we propose a new method for detecting ISCs based on the interacting multiple model (IMM) estimation technique, which can provide a probability for the occurrence of an ISC and simultaneously estimate the short-circuit resistance, indicating the severity of the ISC. The IMM relies on dynamic electrothermal models of parallel cells (nP), both for the healthy mode and short-circuit mode. The IMM technique is combined with unscented Kalman filters (UKFs) to detect internal short circuits and estimate the short-circuit resistance across various synthetic data sets that are corrupted by Gaussian noise for different values of ISC resistance. Fifty short-circuit scenarios were simulated in which one cell in a 46 P cell group underwent an ISC during a drive cycle. The short-circuit resistances ranged from 0.5 to 100 Ω, tested at ten different states of charge (SOCs). Our simulation outputs included busbar voltage, input current, and cell temperatures, which were then corrupted by Gaussian noise. Our IMM successfully detected and estimated the ISC in all fifty cases, with temperature rise remaining below 6 °C before detection, well before the onset of thermal runaway conditions.

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
XOXin Hui Ooi
Xin Hui Ooi
VTVivian Tran
Vivian Tran
Anna StefanopoulouAnna Stefanopoulou
Anna Stefanopoulou
JSJason Siegel
Jason Siegel
RMRobert Middleton
Robert Middleton
JJJudith A. Jeevarajan
Judith A. Jeevarajan
Recent Battery Energy Storage System (BESS) failures highlight the need to detect gases from venting cells as quickly as possible, as well as the vulnerabilities in existing monitoring infrastructure that would alert the occurrence and location of cell venting [1]. Conventional detection strategies, which rely on stationary gas sensors, can fail to identify low-volume gas release from single-cell early stage (first) venting, especially in large-scale BESS that have multiple racks and modules, such as Panel A in Figure 1. Suboptimal or improper fixed sensor placement, gas transport effects (e.g., thermal buoyancy), and dilution below detection thresholds further complicate failure detection. These limitations hinder emergency responders’ ability to accurately assess explosion and/or toxicity risks. To address these challenges, we propose integrating a guided mobile gas sensing platform to complement stationary gas sensors. This system will dynamically monitor spatial and temporal gas evolution during early failure stages by deploying a robotic platform equipped with commercial sensors to detect the most commonly emitted gases (CO2, H2, CO, electrolyte vapor). The robot will patrol accessible areas or be strategically guided to areas of interest to actively sample “suspicious zones” with high concentrations of vent gases. This target navigation will be informed by advanced state-of-health (SOH) diagnostics derived from electrical and thermal measurements typically available in the Battery Management System (BMS) data. A major component of our detection algorithm is to recognize how rapidly a fault is propagating to other cells or the time elapsed from the vent initiation. To this end, we first characterize venting gases in terms of composition, quantity, temperature, and time evolution. A literature review (Figure 1, Panel B) on gas characterization was conducted, and it was found that most prior work focused on global, post-thermal runaway (TR) gas analysis. However, the combustion of vent gases during TR makes their characterization challenging, leaving first venting behavior poorly understood. To address this gap, we aim to develop a systematic way to trigger gas generation without full thermal runaway by inducing controlled overheating and arresting the heat after first venting occurs. We will apply this method to two form factors: cylindrical (2.6 Ah) and prismatic (32 Ah), focusing on LFP cells due to their widespread adoption in grid-scale BESS. After characterizing single-cell behavior, we will construct a representative BESS rack (Figure 1, Panel C) with cells inside modules to study venting propagation from vented cells to the module venting channels and to the rack headspace where the stationary sensors are typically located. Our gas characterization will then inform models and algorithms that can recognize the various stages of an evolving failure, including the location and the number of cells undergoing slow discharge, venting, and/or the propagation of thermal runaway. This will guide the robotic sensor platform to reach the appropriate venting channel, providing a faster response and better guidance for first responders. By integrating robotic mobility with diagnostic and prognostic tools, this will not only improve the detection of first venting events, but also enhance situational awareness for emergency response. It enables high-confidence localization of first venting events, estimates the scale of the fault progression, and quantifies the number of cells involved in or propagating in a thermal runaway event, providing actionable data to guide safer and more rapid containment efforts. ACKNOWLEDGEMENT This project is supported by UL Research Institutes. REFERENCES [1] Srinivasan, L., Shaw, S. and Billaut, E. (2024). Insights from EPRI’s battery energy storage systems (BESS) failure incident database: analysis of failure root cause Figure 1: A typical large-scale Battery Energy Storage System (BESS) with multiple racks and modules (Panel A), an overview of literature showing the lack of vent (pre-thermal runaway) gas characterization for LFP cells (Panel B), and a representative BESS rack with a mockup of the mobile guided gas sensing platform directed to sample from a module vent (Panel C). Figure 1

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
XOXin Hui Ooi
Xin Hui Ooi
HMHamidreza Movahedi
Hamidreza Movahedi
Anna StefanopoulouAnna Stefanopoulou
Anna Stefanopoulou
JSJason Siegel
Jason Siegel
Internal short circuits (ISCs) in batteries occur when electrode layers unintentionally come into contact, creating an unanticipated current path that diverts electrical flow from its intended path, which poses critical safety risks. Manufacturing defects, mechanical stress, lithium plating, or exposure to excessive heat may cause soft shorts, which result in self-discharge heating [1]. Soft shorts with a large short-to-cell resistance ratio (R isc /R 0 >1) are difficult to detect via their electrical signature alone (terminal voltage) but could be observable from their thermal signature. Detection of the soft shorts is vital because they could evolve into hard shorts and lead to thermal runaway. Detection of shorted cells in parallel connected groups is even more critical, as the failure of one cell can cause current from adjacent cells to discharge through the faulty cell, accelerating overheating but having a less recognizable faulty electrical response due to the shared voltage across the parallel group. In our study, we develop simple electrical and thermal circuit submodels for parallel-connected lithium-ion battery cells to investigate their behavior under both normal operating conditions and short-circuit scenarios [2]. We recognize that ISCs can occur in various configurations and consider different ISC architectures by connecting a short-circuit resistor (R isc ) parallel to different segments of an equivalent circuit model (EQM), which consists of an open-circuit voltage function and an internal resistance (OCV-R). Leveraging this scalable model, we analyze the complexities arising from an increasing number of parallel-connected cells. We considered two notable ISC scenarios: one involving a short between the Aluminum and Copper current collectors (Al-Cu ISC) and another between the cathode and anode (Ca-An ISC), the latter of which is associated with lithium dendrite formation [3]. While increasing the number of parallel connections tends to reduce both the voltage drop and temperature rise as generally expected, we discovered that the degree of reduction depends on the specific location of the ISC. This variability complicates ISC detection, especially when dealing with a larger network of interconnected cells. We further demonstrate that thermal runaway risk is governed not by the absolute magnitude of the short-circuit resistance but by its ratio to internal resistance, as well as its relationship to the overall capacity of the cell group. By maintaining this ratio while scaling the resistance magnitudes for both types of ISCs, we evaluate its influence on voltage and temperature trends. In our simulations, we consider a pack of up to 10 parallel-connected NMC cells, where one of the cells experiences an ISC. Notably, for a short that occurs between the current collectors (Al-Cu ISC), the voltage drop and temperature rise responses for a pack of parallel-connected cells are nearly identical as resistance values decrease, provided the ratio of R isc /R 0 is the same. In contrast, for a short between the cell’s cathode and anode (Ca-An ISC), higher resistance magnitudes result in reduced voltage drops and temperature rises. These findings highlight threshold tuning and monitoring strategies to mitigate ISC risks, offering insights that can improve threshold selection for conventional detection methods and tuning parameters for model-based algorithms. REFERENCES [1] Chen, Wei, et al. "Defects in Lithium-Ion Batteries: From Origins to Safety Risks." Green Energy and Intelligent Transportation (2024): 100235. [2] Movahedi, Hamidreza, et al. “Interacting Multiple-Model for Fault Detection and Short Resistance Estimation in Parallel Connected Lithium-ion Batteries.” MECC 2025 (submitted) [3] Zhang, Mingxuan, et al. "Internal short circuit trigger method for lithium-ion battery based on shape memory alloy." Journal of The Electrochemical Society 164.13 (2017): A3038. Figure 1: A model showing parallel-connected cells, with one experiencing one of two internal short circuits: Current collector (Al-Cu) and Dendrite (Ca-An). Their OCV-R representation and physical interpretation are also shown. In the center, the time domain results for terminal voltage, c-rate, and temperature are shown for a pack of 2 and 5 parallel-connected cells. Note that t = 0 is where the ISC was induced. At the bottom, the features of voltage drop and temperature rise one second after the ISC occurrence are plotted against the number of parallel-connected cells in a pack (n = 2, 5, 10). To study their impact on these features, the total resistance of the pack, magnitude of the short-circuit resistance (R isc ), and short-to-cell ratio (R isc /R 0 ) were varied for each nP pack. Figure 1


7 July 2026 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
ARApoorva Roy
Apoorva Roy
VTVivian Tran
Vivian Tran
ZWZhiwen Wan
Zhiwen Wan
XOXin Hui Ooi
Xin Hui Ooi
HMHamidreza Movahedi
Hamidreza Movahedi
Anna StefanopoulouAnna Stefanopoulou
Anna Stefanopoulou
When an electric vehicle (EV) is deemed incapable of achieving the acceleration or driving range desired by its user due to battery deterioration (capacity fade and/or resistance growth), the battery pack is retired but can still be reused for less demanding duty cycles. Prolonging the usage of retired packs via second-life applications such as energy storage systems (ESS) prevents premature pack recycling and helps users extract maximum value from the resources spent in manufacturing batteries. Even though an estimated 30 GWh of second-life batteries (SLBs) are already installed in ESS worldwide without any incidents of thermal runaway reported [1], guaranteeing SLB resiliency and safety continues to remain a concern for new deployments. Repurposers lack access to confidential data from the batteries’ first use including the details about the battery management system (BMS) needed to evaluate SLB health and the risk of safety hazards. Original equipment manufacturers are often unwilling to share the liability burden of repurposing the battery for a new application [2]. In 2018, U.S. based Underwriters Laboratory published the world's first certification standard for retired batteries -- UL 1974 [3]. The standard requires charge and discharge tests on aged cells and comparing the results to their fresh counterparts and reporting capacity, internal resistance, and self discharge rate, but it does not yet specify a test protocol or a set of features that can quantify state of safety (SOS). Therefore, it is necessary to develop and validate feature-based methodologies that can assess the SOS of retired batteries without accessing any historical first-life data, to prevent deployment of potentially hazardous batteries into second-life assets.

23 September 2026 in Journal of Energy Storage
Verified
Journal Article
Open access
CWClement Wong
Clement Wong
AWAndrew Weng
Andrew Weng
XOXin Hui Ooi
Xin Hui Ooi
ZWZhiwen Wan
Zhiwen Wan
JCJeesoon Choi
Jeesoon Choi
Anna StefanopoulouAnna Stefanopoulou
Anna Stefanopoulou