David S. Lalush

David S. Lalush

Auto-generated profile, based on publicly available information

David S. Lalush

Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in NeuroImage
Verified
Journal Article
Closed access
YWYan Wang
Yan Wang
BYBiting Yu
Biting Yu
LWLei Wang
Lei Wang
CZChen Zu
Chen Zu
DLDavid S. Lalush
David S. Lalush
LZLuping Zhou
Luping Zhou

29 November 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Yan WangYan Wang
Yan Wang
LZLuping Zhou
Luping Zhou
BYBiting Yu
Biting Yu
LWLei Wang
Lei Wang
CZChen Zu
Chen Zu
DSDinggang Shen
Dinggang Shen
Positron emission tomography (PET) has been substantially used recently. To minimize the potential health risk caused by the tracer radiation inherent to PET scans, it is of great interest to synthesize the high-quality PET image from the low-dose one to reduce the radiation exposure. In this paper, we propose a 3D auto-context-based locality adaptive multi-modality generative adversarial networks model (LA-GANs) to synthesize the high-quality FDG PET image from the low-dose one with the accompanying MRI images that provide anatomical information. Our work has four contributions. First, different from the traditional methods that treat each image modality as an input channel and apply the same kernel to convolve the whole image, we argue that the contributions of different modalities could vary at different image locations, and therefore a unified kernel for a whole image is not optimal. To address this issue, we propose a locality adaptive strategy for multimodality fusion. Second, we utilize 1 × 1 × 1 kernel to learn this locality adaptive fusion so that the number of additional parameters incurred by our method is kept minimum. Third, the proposed locality adaptive fusion mechanism is learned jointly with the PET image synthesis in a 3D conditional GANs model, which generates high-quality PET images by employing large-sized image patches and hierarchical features. Fourth, we apply the auto-context strategy to our scheme and propose an auto-context LA-GANs model to further refine the quality of synthesized images. Experimental results show that our method outperforms the traditional multi-modality fusion methods used in deep networks, as well as the state-of-the-art PET estimation approaches.

1 April 1998 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
DLDavid S Lalush
David S Lalush
BTBenjamin M W Tsui
Benjamin M W Tsui
We introduce a fast block-iterative maximum a posteriori (MAP) reconstruction algorithm and apply it to four-dimensional reconstruction of gated SPECT perfusion studies. The new algorithm, called RBI-MAP, is based on the rescaled block iterative EM (RBI-EM) algorithm. We develop RBI-MAP based on similarities between the RBI-EM, ML-EM and MAP-EM algorithms. RBI-MAP requires far fewer iterations than MAP-EM, and so should result in acceleration similar to that obtained from using RBI-EM or OS-EM as opposed to ML-EM. When complex four-dimensional clique structures are used in the prior, however, evaluation of the smoothing prior dominates the processing time. We show that a simple scheme for updating the prior term in the heart region only for RBI-MAP results in savings in processing time of a factor of six over MAP-EM. The RBI-MAP algorithm incorporating 3D collimator-detector response compensation is demonstrated on a simulated Tc gated perfusion study. Results of RBI-MAP are compared with RBI-EM followed by a 4D linear filter. For the simulated study, we find that RBI-MAP provides consistently higher defect contrast for a given degree of noise smoothing than does filtered RBI-EM. This is an indication that RBI-MAP smoothing does less to degrade resolution gained from 3D detector response compensation than does a linear filter. We conclude that RBI-MAP can provide smooth four-dimensional reconstructions with good visualization of heart structures in clinically realistic processing times.

1 April 2019 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
SPSteven J. Pfeiffer
Steven J. Pfeiffer
JSJeffrey Spang
Jeffrey Spang
DNDaniel Nissman
Daniel Nissman
DLDavid Lalush
David Lalush
KWKyle Wallace
Kyle Wallace
BPBrian Pietrosimone
Brian Pietrosimone
Purpose: Aberrant walking biomechanics after anterior cruciate ligament reconstruction (ACLR) are hypothesized to be associated with deleterious changes in knee cartilage. T1ρ magnetic resonance imaging (MRI) is sensitive to decreased proteoglycan density of cartilage. Our purpose was to determine associations between T1ρ MRI interlimb ratios (ILR) and walking biomechanics 6 months after ACLR. Methods: Walking biomechanics (peak vertical ground reaction force (vGRF), vGRF loading rate, knee extension moment, knee abduction moment) were extracted from the first 50% of stance phase in 29 individuals with unilateral ACLR. T1ρ MRI ILR (ACLR limb/uninjured limb) was calculated for regions of interest in both medial and lateral femoral (LFC) and medial and lateral tibial condyles. Separate, stepwise linear regressions were used to determine associations between biomechanical outcomes and T1ρ MRI ILR after accounting for walking speed and meniscal/chondral injury ( P ≤ 0.05). Results: Lesser peak vGRF in the ACLR limb was associated with greater T1ρ MRI ILR for the LFC (posterior Δ R 2 = 0.14, P = 0.05; central Δ R 2 = 0.15, P = 0.05) and medial femoral condyle (central Δ R 2 = 0.24, P = 0.01). Lesser peak vGRF loading rate in the ACLR limb (Δ R 2 = 0.21, P = 0.02) and the uninjured limb (Δ R 2 = 0.27, P = 0.01) was associated with greater T1ρ MRI ILR for the anterior LFC. Lesser knee abduction moment for the injured limb was associated with greater T1ρ MRI ILR for the anterior LFC (Δ R 2 = 0.16, P = 0.04) as well as the posterior medial tibial condyle (Δ R 2 = 0.13, P = 0.04). Conclusion: Associations between outcomes related to lesser mechanical loading during walking and greater T1ρ MRI ILR were found 6 months after ACLR. Although preliminary, our results suggest that underloading of the ACLR limb at 6 months after ACLR may be associated with lesser proteoglycan density in the ACLR limb compared with the uninjured limb.

25 March 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
GCG Cao
G Cao
YLYueh Z Lee
Yueh Z Lee
RPR Peng
R Peng
ZLZ Liu
Z Liu
RRR Rajaram
R Rajaram
OZO Zhou
O Zhou
Current commercial micro-CT scanners have the capability of imaging objects ex vivo with high spatial resolution, but performing in vivo micro-CT on free-breathing small animals is still challenging because their physiological motions are non-periodic and much faster than those of humans. In this paper, we present a prototype physiologically gated micro-computed tomography (micro-CT) scanner based on a carbon nanotube field emission micro-focus x-ray source. The novel x-ray source allows x-ray pulses and imaging sequences to be readily synchronized and gated to non-periodic physiological signals from small animals. The system performance is evaluated using phantoms and sacrificed and anesthetized mice. Prospective respiratory-gated micro-CT images of anesthetized free-breathing mice were collected using this scanner at 50 ms temporal resolution and 6.2 lp mm(-1) at 10% system MTF. The high spatial and temporal resolutions of the micro-CT scanner make it well suited for high-resolution imaging of free-breathing small animals.

6 January 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
YWYan Wang
Yan Wang
PZPei Zhang
Pei Zhang
LALe An
Le An
GMGuangkai Ma
Guangkai Ma
JKJiayin Kang
Jiayin Kang
DSDinggang Shen
Dinggang Shen
Positron emission tomography (PET) has been widely used in clinical diagnosis for diseases and disorders. To obtain high-quality PET images requires a standard-dose radionuclide (tracer) injection into the human body, which inevitably increases risk of radiation exposure. One possible solution to this problem is to predict the standard-dose PET image from its low-dose counterpart and its corresponding multimodal magnetic resonance (MR) images. Inspired by the success of patch-based sparse representation (SR) in super-resolution image reconstruction, we propose a mapping-based SR ( m -SR) framework for standard-dose PET image prediction. Compared with the conventional patch-based SR, our method uses a mapping strategy to ensure that the sparse coefficients, estimated from the multimodal MR images and low-dose PET image, can be applied directly to the prediction of standard-dose PET image. As the mapping between multimodal MR images (or low-dose PET image) and standard-dose PET images can be particularly complex, one step of mapping is often insufficient. To this end, an incremental refinement framework is therefore proposed. Specifically, the predicted standard-dose PET image is further mapped to the target standard-dose PET image, and then the SR is performed again to predict a new standard-dose PET image. This procedure can be repeated for prediction refinement of the iterations. Also, a patch selection based dictionary construction method is further used to speed up the prediction process. The proposed method is validated on a human brain dataset. The experimental results show that our method can outperform benchmark methods in both qualitative and quantitative measures.