Yunus Kizilarslan

Yunus Kizilarslan

Auto-generated profile, based on publicly available information

Yunus Kizilarslan

Ulaşım İç ve Dış Ticaret A.Ş.

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2025 in Cukurova University Journal of Natural and Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMuhammed Kürşad Baştürk
Muhammed Kürşad Baştürk
YKYunus Kizilarslan
Yunus Kizilarslan
Studies on energy efficiency and storage are being conducted both globally. Considering energy efficiency, safety, environmental impact, and total costs throughout the lifespan of electric vehicles, proper battery selection is crucial for reducing greenhouse gas emissions and optimizing energy resource usage. Parameters such as energy density, cycle life, charging time, thermal runaway risk, and cost play a significant role in determining the right battery type, particularly for public transportation vehicles. This study com-pares the parameters of LFP, LTO, and NMC batteries used in electric buses and examines their performances under identical usage scenarios and weights. To determine the most suitable battery chemistry for electric buses, a 10-year simulation was conduct-ed based on SORT-2 (Standardized On-Road Test Cycle) and the Istanbul Metrobus driving cycles, analyzing parameters such as energy density, cycle life, daily charging counts, energy consumption per kilometer, and energy consumption over a daily range of 400 km. Previous studies in the literature have emphasized the importance of selecting the appropriate battery type to enhance energy efficiency, especially in public transportation vehicles. Simulation results indicate that while LFP batteries offer long cycle life and low spatial requirements, they are disadvantageous in terms of energy density and fast charging/discharging. LTO batteries exhibit the highest cycle life and fastest charging/discharging capabilities, but their low energy density and high spatial requirements are notable drawbacks. NMC batteries provide high energy density and spatial advantages but suffer from low cycle life and ther-mal runaway risks

30 June 2026 in Cukurova University Journal of Natural and Applied Sciences
Verified
Journal Article
Closed access
YKYunus Kizilarslan
Yunus Kizilarslan
OAOğuzhan Arı
Oğuzhan Arı
In this study, the impact of different battery voltage architectures on energy efficiency, driving range, and charging performance of urban electric buses was analyzed using a MATLAB/Simulink-based simulation model. The objective was to comparatively evaluate the effects of 600 V and 800 V battery systems on overall vehicle energy management. The model consisted of vehicle dynamics, electric motor, battery system, and charging subsystems. Three scenarios were investigated: (S1) a 600 V system with 350 kWh capacity, (S2) an 800 V system with 490 kWh capacity, and (S3) an 800 V system with 352 kWh capacity. All scenarios were simulated under the SORT-1 driving cycle between 100% and 20% state of charge. Results showed that the 800 V architecture achieved approximately 1.1% lower normalized energy consumption (Wh/ton·km) compared to the 600 V system with similar capacity. Increasing battery capacity from 350 kWh to 490 kWh extended the driving range by about 39%. Charging analysis indicated comparable charging durations for equal energy transfer, while the 800 V system enabled lower current levels, reduced transmission losses, and improved fast-charging efficiency. The findings demonstrate that battery voltage level and pack configuration play a critical role in the energy efficiency and operational performance of urban electric buses.

30 September 2026 in Bitlis Eren Üniversitesi Fen Bilimleri Dergisi
Verified
Journal Article
Closed access
OAOğuzhan Arı
Oğuzhan Arı
YKYunus Kizilarslan
Yunus Kizilarslan
In this study, the energy consumption of a 10.5 m, 12,500 kg electric bus was modelled in MATLAB/Simulink under varying frontal areas and road conditions. Vehicle specifications were kept constant, while only frontal area and the rolling resistance coefficient, depending on road conditions, were altered. The analysis was based on the first and second trapezoids (30 km/h and 50 km/h) of the SORT-3 cycle. The results indicate that increasing the frontal area by 20% raised the energy consumption by approximately 2–3%. In contrast, the influence of road surface was far more significant, with gravel roads causing 35–40% higher consumption compared to asphalt. Regenerative braking reduced net energy demand, with recovery ratios of 35–41% on asphalt and 27–31% on gravel. The findings show that in the planning and operation of electric bus fleets, considering both aerodynamic design and route surface conditions is decisive for improving energy efficiency.

29 December 2025 in Cukurova University Journal of Natural and Applied Sciences
Verified
Journal Article
Closed access
YKYunus Kizilarslan
Yunus Kizilarslan
OAOğuzhan Arı
Oğuzhan Arı
SKSezgin Kaçar
Sezgin Kaçar
This study presents a MATLAB/Simulink-based analysis to investigate the effect of differential gear ratios on the energy consumption of a 13-meter low-entry electric city bus. Four differential ratios (5.12, 5.73, 6.19, and 7.36) were simulated under SORT-1, SORT-2, and SORT-3 driving cycles, representing different urban operation patterns. The developed simulation model incorporates vehicle longitudinal dynamics, motor efficiency maps, and battery energy flow. Results indicate that increasing the differential ratio reduces the specific energy consumption in all driving cycles. The lowest value of 1.747 kWh/km was obtained at a 7.36 ratio under the SORT-3 cycle. The recovery ratio remained stable around 27 ± 1 %, confirming consistent regenerative braking performance. The findings highlight the importance of differential ratio selection for optimizing the drivetrain efficiency of electric buses and can serve as a guideline for future powertrain configurations in urban public transport applications.