Jeff Terry

Jeff Terry

Auto-generated profile, based on publicly available information

Jeff Terry

Department of Physics, Illinois Institute of Technology 1 , 3101 South Dearborn Street, Chicago, Illinois 60616

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2020 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
GMGeorge H. Major
George H. Major
NFNeal Fairley
Neal Fairley
PSPeter M. A. Sherwood
Peter M. A. Sherwood
MLMatthew Linford
Matthew Linford
JTJeff Terry
Jeff Terry
KAKateryna Artyushkova
Kateryna Artyushkova
The use of peak fitting to extract information from x-ray photoelectron spectroscopy (XPS) data is of growing use and importance. Due to increased instrument accessibility and reliability, the use of XPS instrumentation has significantly increased around the world. However, the increased use has not been matched by the expertise of the new users, and the erroneous application of curve fitting has contributed to ambiguity and confusion in parts of the literature. This guide discusses the physics and chemistry involved in generating XPS spectra, describes good practices for peak fitting, and provides examples of appropriate use along with tools for avoiding mistakes.

1 May 2023 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
GMGeorge H. Major
George H. Major
JPJoshua W. Pinder
Joshua W. Pinder
DADaniel E. Austin
Daniel E. Austin
DBDonald R. Baer
Donald R. Baer
SCSteven L. Castle
Steven L. Castle
MLMatthew Linford
Matthew Linford
Due to significant advances in instrumentation, many previously specialized techniques have become “routine” in user facilities. However, detailed knowledge held by experts has often not been relayed to general users, so they often rely on entry-level information, basic principles, and comparison with literature results for data analysis. As a result, major errors in the data analysis of multiple surface and material analysis techniques, including in x-ray photoelectron spectroscopy (XPS), have been appearing in the scientific literature. Representative examples of serious errors in XPS data analysis are shown in this work. We suggest that surface and material analysis, and perhaps even science in general, are in a state of “pre-crisis.” We use two (logistic) models from population biology to suggest that bad analyses self-correct if they remain below a critical number. However, beyond a threshold, the literature can become useless because of the perpetuation of faulty analyses and concomitant loss of its self-correcting ability. XPS is used by scientists in many communities because of the power of the technique and high-quality instrumentation that is commercially available. Those who make new surfaces and materials face unique challenges because of the large number of surface and material analytical techniques that are often needed to characterize their materials. Graduate students and post-docs are often provided with only minimal instruction on using surface and material characterization methods. High fees for instruments may affect both the quality and the quantity of the data people collect. The Prisoner's Dilemma is a model from game theory that describes situations with reward structures that encourage uncooperative behavior and lead to suboptimal outcomes. However, the outcomes of Prisoner's Dilemma are not inevitable—their consequences change if their reward structures change. The current system does not appear to incentivize detailed learning of surface and material characterization techniques and careful material characterization. Prisoner's dilemmas appear to lead to other undesirable consequences in science. The concerns raised in this work suggest that many manuscripts are incompletely reviewed at present. The different stakeholders in this problem, including authors, research advisers, subject matter experts, reviewers, scientists who notice examples of faulty data analysis, editors, journals and publishers, funding agencies, scientific societies, leaders at universities and research centers, and instrument vendors, can improve the current situation. This work provides specific recommendations for each of these stakeholders. For example, we believe that authors are primarily responsible for the correctness of their work, not reviewers or editors; we question the wisdom of listing the names of the editor and reviewers on a paper; we are grateful for the significant contributions that have been made by subject matter experts to produce standards and tutorial information; the high cost of instrument time at some institutions may limit student access and result in suboptimal analyses; staff scientists often need to be better recognized for their intellectual contributions to studies; publishers may wish to allow selective reviewing of specific sections of papers related to material characterization; the reviewing at some open access journals may be inadequate; while it had its shortcomings, the pre-open access model of publishing incentivized the production and publication of high-quality work; audits of the products (scientific papers) of funding agencies may be necessary; collaboration needs to be encouraged to a greater extent at some institutions; and instrument vendors should not suggest to potential customers that surface characterization, e.g., by XPS, is trivial or simple.

4 March 2016 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
DVDaniel Velázquez
Daniel Velázquez
RSRachel Seibert
Rachel Seibert
HMHamdi Man
Hamdi Man
LSLinda Spentzouris
Linda Spentzouris
JTJeff Terry
Jeff Terry
We report on the growth of 1–10 ML films of hexagonal boron nitride (h-BN), also known as white graphene, on fiber-oriented Ag buffer films on SrTiO3(001) by pulsed laser deposition. The Ag buffer films of 40 nm thickness were used as substitutes for expensive single crystal metallic substrates. In-situ, reflection high-energy electron diffraction was used to monitor the surface structure of the Ag films and to observe the formation of the characteristic h-BN diffraction pattern. Further evidence of the growth of h-BN was provided by attenuated total reflectance spectroscopy, which showed the characteristic h-BN peaks at ∼780 cm−1 and 1367.4 cm−1. Ex-situ photoelectron spectroscopy showed that the surface of the h-BN films is stoichiometric. The physical structure of the films was confirmed by scanning electron microscopy. The h-BN films grew as large, sub-millimeter sheets with nano- and micro-sheets scattered on the surface. The h-BN sheets can be exfoliated by the micromechanical adhesive tape method. Spectral analysis was performed by energy dispersive spectroscopy in order to identify the h-BN sheets after exfoliation. The use of thin film Ag allows for reduced use of Ag and makes it possible to adjust the surface morphology of the thin film prior to h-BN growth.

17 May 2023 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
GMGeorge H. Major
George H. Major
BCB. Maxwell Clark
B. Maxwell Clark
KCKevin Cayabyab
Kevin Cayabyab
NENathan Engel
Nathan Engel
CEChristopher D. Easton
Christopher D. Easton
MLMatthew Linford
Matthew Linford
This study was motivated by earlier observations. It is a systematic examination of the adequacy of reporting of information (metadata) necessary to understand x-ray photoelectron spectroscopy (XPS) data collection and data analysis in the scientific literature. The information for this study was obtained from papers published in three high-quality journals over a six-month period in 2019 and throughout 2021. Each paper was evaluated to determine whether the authors had reported (percentages of the papers properly providing the information are given in parentheses) the spectrometer (66%), fitting software (15%), x-ray source (40%), pass energy (10%), spot size (5%), synthetic peak shapes in fits (10%), backgrounds in fits (10%), whether the XPS data are shown in the main body of the paper or in the supporting information (or both), and whether fitted or unfitted spectra were shown (80% of published spectra are fit). The Shirley background is the most widely used background in XPS peak fitting. The Al Kα source is the most widely used x-ray source for XPS data collection. casaxps is the most widely used fitting program for XPS data analysis. There is good agreement between the results gathered during the two years of our survey. There are some hints the situation may be improving. This study also provides a list of the information/parameters that should be reported when XPS is performed.

3 November 2023 in Journal of Vacuum Science & Technology A
Verified
Journal Article
Open access
PDF file
MLMiu Lun Lau
Miu Lun Lau
ABAbraham Burleigh
Abraham Burleigh
JTJeff Terry
Jeff Terry
MLMin Long
Min Long
Material characterization techniques are widely used to characterize the physical and chemical properties of materials at the nanoscale and, thus, play central roles in material scientific discoveries. However, the large and complex datasets generated by these techniques often require significant human effort to interpret and extract meaningful physicochemical insights. Artificial intelligence (AI) techniques such as machine learning (ML) have the potential to improve the efficiency and accuracy of surface analysis by automating data analysis and interpretation. In this perspective paper, we review the current role of AI in surface analysis and discuss its future potential to accelerate discoveries in surface science, materials science, and interface science. We highlight several applications where AI has already been used to analyze surface analysis data, including the identification of crystal structures from XRD data, analysis of XPS spectra for surface composition, and the interpretation of TEM and SEM images for particle morphology and size. We also discuss the challenges and opportunities associated with the integration of AI into surface analysis workflows. These include the need for large and diverse datasets for training ML models, the importance of feature selection and representation, and the potential for ML to enable new insights and discoveries by identifying patterns and relationships in complex datasets. Most importantly, AI analyzed data must not just find the best mathematical description of the data, but it must find the most physical and chemically meaningful results. In addition, the need for reproducibility in scientific research has become increasingly important in recent years. The advancement of AI, including both conventional and the increasing popular deep learning, is showing promise in addressing those challenges by enabling the execution and verification of scientific progress. By training models on large experimental datasets and providing automated analysis and data interpretation, AI can help to ensure that scientific results are reproducible and reliable. Although integration of knowledge and AI models must be considered for the transparency and interpretability of models, the incorporation of AI into the data collection and processing workflow will significantly enhance the efficiency and accuracy of various surface analysis techniques and deepen our understanding at an accelerated pace.

18 October 2021 in Environmental Science: Nano
Verified
Journal Article
Closed access
PDF file
HLHongjuan Liu
Hongjuan Liu
XWXianli Wang
Xianli Wang
TAThulitha Abeywickrama
Thulitha Abeywickrama
FJForough Jahanbazi
Forough Jahanbazi
ZMZefu Min
Zefu Min
Yuanbing MaoYuanbing Mao
Yuanbing Mao
Radionuclides and heavy metal ions have become the main harmful pollutants in the environment. Developing sensitive and rapid methods to detect them from natural water or wastewater is important to reduce their exposure risks. In this study, a novel luminescent Tb3+-doped fluorapatite/agar nanocomposite (Tb-FAP/agar) has been synthesized via a facile and green synthetic route through an environmentally friendly biomineralization process using agar as a template. This nanocomposite is the first luminescent fluorapatite for detecting UO2 2+, Cu2+, and Cr3+ ions in water with high selectivity and sensitivity based on luminescence turn-off effects. The detection limits of the Tb-FAP/agar for UO2 2+ (7.95 nM), Cu2+ (3.94 nM), and Cr3+ (1.67 nM) are much lower than the permissible limits in drinking water defined by the United States Environmental Protection Agency (USEPA). Furthermore, the luminescence detection mechanisms for UO2 2+, Cu2+, and Cr3+ ions were speculated. Our study provides insight into developing biodegradable rare earth doped fluorapatite probes for the detection of both radioactive and nonradioactive ions.