26 March 2019 in IEEE Transactions on Power Electronics
Conventionally, additional control levels are often introduced in a dc microgrid (MG) to ensure equal power sharing among distributed energy resources (DERs). To achieve this, it is necessary for the supervisory controller to collect multiple operation signals of all DERs. Thus, the burden of communication increases with increased usage of DERs. Additionally, high requirements on communication links decrease the flexibility and reliability of dc MGs. In this paper, an improved secondary control strategy with maximum loading factor (MLF) for accurate power sharing in dc MGs is proposed. In this method, the MLF is used to achieve an auto-selection of the leader converter with differential delay methods. Additionally, the compensation value for power sharing improvement is calculated at the secondary control level. In contrast with the conventional approaches, the only signal transmitted in the communication link corresponded to the MLF, and thus power sharing is realized with ultra-low bandwidth communication. After receiving the MLF signal, the compensation value is calculated in the local converter. Thus, the centralized secondary controller or master controller is not required. Finally, performance of the proposed control scheme with different time latencies is verified via hardware-in-the-loop tests for different scenarios.
11 December 2020 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Hybrid AC-DC systems integrate ac bus and various dc buses as well as multiple power electronic converters, and such systems are consequently vulnerable to instability issues. In order to investigate the stabilities of hybrid AC-DC systems with multiple dc buses and identify which converters are mainly responsible for instability, this paper proposes a stage-by-stage stability analysis method. The small-signal models of AC-DC and DC-DC converters are established, based upon which the whole system is separated into multiple stages according to its structure, and checked stage-by-stage. Make sure that equivalent input admittance (or impedance) of stage k (k=2, 3, …) has no right-half-plane poles so that it is self-stable, then consider the equivalent input admittance (or impedance) of stage k as the equivalent load admittance (or impedance) of stage k-1, and check the stability of stage k-1; and repeat the process until the whole system has been checked. All stage being stable can ensure the stability of overall system. The converters that are mainly responsible for instability can be clearly identified by this stage-by-stage method, and it could be beneficial for stability enhancement of the system. The effectiveness of the proposed method is verified by simulations in PSCAD/EMTDC and experiments of the control hardware in the loop (CHIL).