Wilhelm von Rosenberg

Wilhelm von Rosenberg

Auto-generated profile, based on publicly available information

Wilhelm von Rosenberg

Department of Electrical and Electronic Engineering, Imperial College London, London, UK

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2017 in Frontiers in Physiology
Verified
Journal Article
Open access
WRWilhelm von Rosenberg
Wilhelm von Rosenberg
TCTheerasak Chanwimalueang
Theerasak Chanwimalueang
TATricia Adjei
Tricia Adjei
UJUsman Jaffer
Usman Jaffer
VGValentin Goverdovsky
Valentin Goverdovsky
DMDanilo Mandic
Danilo Mandic
It is generally accepted that the activities of the autonomic nervous system (ANS), which consists of the sympathetic (SNS) and parasympathetic nervous systems (PNS), are reflected in the low- (LF) and high-frequency (HF) bands in heart rate variability (HRV) – while, not without some controversy, the ratio of the powers in those frequency bands, the so called LFHF ratio (LF/HF), has been used to quantify the degree of sympathovagal balance. Indeed, recent studies demonstrate that, in general: (i) sympathovagal balance cannot be accurately measured via the ratio of the LF- and HF- power bands; and (ii) the correspondence between the LF/HF ratio and the psychological and physiological state of a person is not unique. Since the standard LF/HF ratio provides only a single degree of freedom for the analysis of this 2D phenomenon, we propose a joint treatment of the LF and HF powers in HRV within a two-dimensional representation framework, thus providing the required degrees of freedom. By virtue of the proposed 2D representation, the restrictive assumption of the linear dependence between the activity of the autonomic nervous system (ANS) and the LF-HF frequency band powers is demonstrated to become unnecessary. The proposed analysis framework also opens up completely new possibilities for a more comprehensive and rigorous examination of HRV in relation to physical and mental states of an individual, and makes possible the categorization of different stress states based on HRV. In addition, based on instantaneous amplitudes of Hilbert-transformed LF- and HF-bands, a novel approach to estimate the markers of stress in HRV is proposed and is shown to improve the robustness to artefacts and irregularities, critical issues in real-world recordings. The proposed approach for resolving the ambiguities in the standard LF/HF-ratio analyses is verified over a number of real-world stress-invoking scenarios.

31 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VGValentin Goverdovsky
Valentin Goverdovsky
WRWilhelm von Rosenberg
Wilhelm von Rosenberg
TNTakashi Nakamura
Takashi Nakamura
DLDavid Looney
David Looney
DSDavid J. Sharp
David J. Sharp
DMDanilo Mandic
Danilo Mandic
Future health systems require the means to assess and track the neural and physiological function of a user over long periods of time, and in the community. Human body responses are manifested through multiple, interacting modalities – the mechanical, electrical and chemical; yet, current physiological monitors (e.g. actigraphy, heart rate) largely lack in cross-modal ability, are inconvenient and/or stigmatizing. We address these challenges through aninconspicuousearpiece, which benefits from the relatively stable position of the ear canal with respect to vital organs. Equipped with miniature multimodal sensors, it robustly measures the brain, cardiac and respiratory functions. Comprehensive experiments validate each modality within the proposed earpiece, while its potential in wearable health monitoring is illustrated through case studies spanning these three functions. We further demonstrate how combining data from multiple sensors within such an integrated wearable device improves both the accuracy of measurements and the ability to deal with artifacts in real-world scenarios.

1 November 2016 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
WRWilhelm Von Rosenberg
Wilhelm Von Rosenberg
TCTheerasak Chanwimalueang
Theerasak Chanwimalueang
VGValentin Goverdovsky
Valentin Goverdovsky
DLDavid Looney
David Looney
DSDavid Sharp
David Sharp
DMDanilo Mandic
Danilo Mandic
Modern wearable technologies have enabled continuous recording of vital signs, however, for activities such as cycling, motor-racing, or military engagement, a helmet with embedded sensors would provide maximum convenience and the opportunity to monitor simultaneously both the vital signs and the electroencephalogram (EEG). To this end, we investigate the feasibility of recording the electrocardiogram (ECG), respiration, and EEG from face-lead locations, by embedding multiple electrodes within a standard helmet. The electrode positions are at the lower jaw, mastoids, and forehead, while for validation purposes a respiration belt around the thorax and a reference ECG from the chest serve as ground truth to assess the performance. The within-helmet EEG is verified by exposing the subjects to periodic visual and auditory stimuli and screening the recordings for the steady-state evoked potentials in response to these stimuli. Cycling and walking are chosen as real-world activities to illustrate how to deal with the so-induced irregular motion artifacts, which contaminate the recordings. We also propose a multivariate R-peak detection algorithm suitable for such noisy environments. Recordings in real-world scenarios support a proof of concept of the feasibility of recording vital signs and EEG from the proposed smart helmet.

7 August 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
VOVânia Oliveira
Vânia Oliveira
WRWilhelm von Rosenberg
Wilhelm von Rosenberg
Paolo MontaldoPaolo Montaldo
Paolo Montaldo
TATricia Adjei
Tricia Adjei
JMJosephine Mendoza
Josephine Mendoza
STSudhin Thayyil
Sudhin Thayyil
Background: Despite the increasing interest in fetal and neonatal heart rate variability (HRV) analysis and its potential use as a tool for early disease stratification, no studies have previously described the normal trends of HRV in healthy babies during the first hours of postnatal life. Methods: We prospectively recruited 150 healthy babies from the postnatal ward and continuously recorded their electrocardiogram during the first 24 h after birth. Babies were included if born in good condition and stayed with their mother. Babies requiring any medication or treatment were excluded. Five-minute segments of the electrocardiogram (non-overlapping time-windows) with more than 90% consecutive good quality beats were included in the calculation of hourly medians and interquartile ranges to describe HRV trends over the first 24 h. We used multilevel mixed effects regression with auto-regressive covariance structure for all repeated measures analysis and t-tests to compare group differences. Non-normally distributed variables were log-transformed. Results: Nine out of 16 HRV metrics (including heart rate) changed significantly over the 24 h [Heart rate p < 0.01; Standard deviation of the NN intervals p = 0.01; Standard deviation of the Poincaré plot lengthwise p < 0.01; Cardiac sympathetic index (CSI) p < 0.01; Normalized high frequency power p = 0.03; Normalized low frequency power p < 0.01; Total power p < 0.01; HRV index p = 0.01; Parseval index p = 0.03], adjusted for relevant clinical variables. We observed an increase in several HRV metrics during the first 6 h followed by a gradual normalization by approximately 12 h of age. Between 6 and 12 h of age, only heart rate and the normalized low frequency power changed significantly, while between 12 and 18 h no metric, other than heart rate, changed significantly. Analysis with multilevel mixed effects regression analysis (multivariable) revealed that gestational age, reduced fetal movements, cardiotocography and maternal chronic or pregnancy induced illness were significant predictors of several HRV metrics. Conclusion: Heart rate variability changes significantly during the first day of life, particularly during the first 6 h. The significant correlations between HRV and clinical risk variables support the hypothesis that HRV is a good indicator of overall wellbeing of a baby and is sensitive to detect birth-related stress and monitor its resolution over time.

15 November 2017 in Royal Society Open Science
Verified
Journal Article
Open access
WRWilhelm von Rosenberg
Wilhelm von Rosenberg
TCTheerasak Chanwimalueang
Theerasak Chanwimalueang
VGValentin Goverdovsky
Valentin Goverdovsky
NPNicholas S. Peters
Nicholas S. Peters
CPChristos Papavassiliou
Christos Papavassiliou
DMDanilo Mandic
Danilo Mandic
Mobile technologies for the recording of vital signs and neural signals are envisaged to underpin the operation of future health services. For practical purposes, unobtrusive devices are favoured, such as those embedded in a helmet or incorporated onto an earplug. However, these locations have so far been underexplored, as the comparably narrow neck impedes the propagation of vital signals from the torso to the head surface. To establish the principles behind electrocardiogram (ECG) recordings from head and ear locations, we first introduce a realistic three-dimensional biophysics model for the propagation of cardiac electric potentials to the head surface, which demonstrates the feasibility of head-ECG recordings. Next, the proposed biophysics propagation model is verified over comprehensive real-world experiments based on head- and in-ear-ECG measurements. It is shown both that the proposed model is an excellent match for the recordings, and that the quality of head- and ear-ECG is sufficient for a reliable identification of the timing and shape of the characteristic P-, Q-, R-, S- and T-waves within the cardiac cycle. This opens up a range of new possibilities in the identification and management of heart conditions, such as myocardial infarction and atrial fibrillation, based on 24/7 continuous in-ear measurements. The study therefore paves the way for the incorporation of the cardiac modality into future ‘hearables’, unobtrusive devices for health monitoring.

1 July 2015
Verified
Conference Paper
Closed access
TCTheerasak Chanwimalueang
Theerasak Chanwimalueang
WRWilhelm von Rosenberg
Wilhelm von Rosenberg
DMDanilo P. Mandic
Danilo P. Mandic
Precise detection of R-peaks is a prerequisite in real-world ECG applications - this is particularly critical for wearable ECG where sensors are typically low resolution and embedded. Such recorded ECG data are typically contaminated by noise, motion artefacts, unbalanced skin-electrode impedance and other physiological signals. These affect the quality of R-peak detection and can consequently lead to failure in the evaluation of physiological functions or a misinterpretation of the state of the body, such as in monitoring stress. While numerous methods for R-peak detection are available for stationary and comparably noise-free ECG, robust DSP software for wearable devices is still emerging. To this end, a new approach which combines matched filtering and Hilbert transform is proposed. The RR-intervals and cross-correlation are used in conjunction to not only automatically locate the R-peaks but also to display the candidate ambiguous peaks via an interactive graphical user interface. The performance of the proposed approach is compared to the well-known Pan-Tompkins algorithm and is evaluated for two types of ECG databases: standard stationary data and low-SNR ECG data obtained from wearable ECG. The proposed method results in a distinctly higher positive predictivity and leads to more satisfying overall outcomes, especially for the critical call of low-SNR data.