Sonja Dieterich

Sonja Dieterich

Auto-generated profile, based on publicly available information

Sonja Dieterich

Department of Radiation Oncology, University of California Davis Medical Center, Sacramento, CA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2011 in Medical Physics
Verified
Journal Article
Closed access
SDSonja Dieterich
Sonja Dieterich
CCCarlo Cavedon
Carlo Cavedon
CCCynthia F. Chuang
Cynthia F. Chuang
ACAlan B. Cohen
Alan B. Cohen
JGJeffrey A. Garrett
Jeffrey A. Garrett
CYCheng Yu
Cheng Yu

1 May 2005 in Journal of Neurosurgery: Spine
Verified
Journal Article
Closed access
JDJeffrey W. Degen
Jeffrey W. Degen
GGGregory J. Gagnon
Gregory J. Gagnon
JVJean-Marc Voyadzis
Jean-Marc Voyadzis
DMDonald A. McRae
Donald A. McRae
MLMichael Lunsden
Michael Lunsden
FHFraser C. Henderson
Fraser C. Henderson
Object.The authors conducted a study to assess safety, pain, and quality of life (QOL) outcomes following CyberKnife radiosurgical treatment of spinal tumors.Methods.Data obtained in all patients with spinal tumors who underwent CyberKnife radiosurgery at Georgetown University Hospital between March 2002 and March 2003 were analyzed. Patients underwent examination, visual analog scale (VAS) pain assessment, and completed the 12-item Short Form Health Survey (SF-12) before treatment and at 1, 3, 6, 8, 12, 18, and 24 months following treatment.Fifty-one patients with 72 lesions (58 metastatic and 14 primary) were treated. The mean follow-up period was 1 year. Pain was improved, with the mean VAS score decreasing significantly from 51.5 to 21.3 at 4 weeks (p < 0.001). This effect on pain was durable, with a mean score of 17.5 at 1 year, which was still significantly decreased (p = 0.002).Quality of life was maintained throughout the study period. After 18 months, physical well-being was 33 (initial score 32; p = 0.96) and mental well-being was 43.8 (initial score 44.2; p = 0.97). (The mean SF-12 score is 50 ± 10 [standard deviation].) Adverse effects included self-limited dysphagia (three cases), diarrhea (two cases), lethargy (three cases), paresthesias (one case), and wound dehiscence (one case).Conclusions.CyberKnife radiosurgery improves pain control and maintains QOL in patients treated for spinal tumors. Early adverse events are infrequent and minor. The authors await long-term follow-up data to determine late complications and tumor control rates.

17 June 2008 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
YSYelin Suh
Yelin Suh
SDSonja Dieterich
Sonja Dieterich
BCByungchul Cho
Byungchul Cho
PKPaul J Keall
Paul J Keall
An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients was performed using more than 70 h of tumour motion estimated from the correlation between the external and internal motion for 143 treatment fractions in 42 patients. The tumour sites included lungs (30 patients) and retroperitoneum (12 patients). The overall mean respiratory-induced peak-to-trough distance was 0.48 cm, with individual treatment fraction means ranging from 0.02 to 1.44 cm. The overall mean respiratory period was 3.8 s, with individual treatment fraction means ranging from 2.2 to 6.4 s. In 57 treatment fractions (40%), the mean respiratory-induced peak-to-trough distance was greater than 0.5 cm. In general, tumour motion was predominantly superior-inferior (60% of all the treatment fractions), while anterior-posterior and left-right motion were 22% and 18%, respectively. The motion was predominantly linear, and the overall mean of the first principal component was 94%. However, for motion magnitude, direction and linearity, large variations were observed from patient to patient, fraction to fraction and cycle to cycle.

1 December 2010 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
JMJames D. Murphy
James D. Murphy
CCClaudia Christman-Skieller
Claudia Christman-Skieller
JKJeff Kim
Jeff Kim
SDSonja Dieterich
Sonja Dieterich
DCDaniel T. Chang
Daniel T. Chang
AKAlbert C. Koong
Albert C. Koong

1 August 2006 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
PKPaul J. Keall
Paul J. Keall
HCHerbert Cattell
Herbert Cattell
DPDamodar Pokhrel
Damodar Pokhrel
SDSonja Dieterich
Sonja Dieterich
KWKenneth H. Wong
Kenneth H. Wong
RMRadhe Mohan
Radhe Mohan

26 October 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MMMartin J Murphy
Martin J Murphy
SDSonja Dieterich
Sonja Dieterich
Breathing adaptation during external-beam radiotherapy is a matter of great concern because uncompensated tumour motion requires extended treatment margins that endanger sensitive tissue. Compensation strategies include beam gating, collimator tracking and robotic beam re-alignment. All of these schemes have a system latency of up to several hundred milliseconds, which calls in turn for predictive control loops. Irregularities in breathing make prediction difficult. We have evaluated the performance of two classes of control loop algorithms-the linear adaptive filter and the adaptive nonlinear neural network-for highly irregular patient breathing behaviours. The neural network demonstrated robust adaptability to all of the observed breathing patterns while the linear filter failed in a significant percentage of cases. For those cases where the linear filter could function, it made less accurate predictions than the neural network. Because the neural network presents no additional computational burden in the control loop we conclude that it is the preferred choice among heuristic predictive algorithms.