8 January 2024 in IEEE Sensors Journal
Ultrasonic surface wave electromagnetic acoustic transducers (EMATs) have been widely utilized in detecting surface defects of metal materials due to their non-contact advantages. However, the signal energy of surface wave EMAT is weak, mainly influenced by energy conversion efficiency. Increasing the number of excitation signal cycles can enhance the signal energy, but it leads to longer pulse width and reduced time-domain resolution. Meanwhile, most of the existing studies excite surface waves with a single frequency, and the frequency information components are limited. To overcome these issues, wideband signal is introduced into the design of surface wave EMAT, and combined with pulse compression technique to obtain surface wave signals with wideband, high amplitude and narrow pulse width. In this paper, a new wideband pulse compression surface wave EMAT (WPCSW-EMAT) is proposed. WPCSW-EMAT replaces the single frequency signal in conventional EMAT with a linear frequency modulation (LFM) signal. Additionally, the equal meander-line coil is replaced by a variable distance meander-line coil, where the distance between adjacent wires matches the frequency change of the LFM signal. Finite element simulation results demonstrate that compared to conventional EMAT, WPCSW-EMAT can obtain pulse compression surface wave signals with wideband frequency, high amplitude, and narrow pulse width. The performance verification experiment and defect detection experiment of EMAT were carried out on aluminum plate samples, and the experimental results indicate that the wideband pulse compression surface wave signal excited by WPCSW-EMAT is more suitable for nondestructive testing of metal materials.
25 November 2021 in IEEE Sensors Journal
In this study, an advanced magnetoacoustic compound inspection method for a high-order Lamb waves mode electromagnetic acoustic transducer (EMAT) was proposed. The proposed EMAT can achieve the excitation and reception of the A 1 mode which is the first-order Lamb waves mode. According to the characteristics of the A 1 mode EMAT testing signal, a signal processing method for obtaining the pulsed eddy current signal by curve fitting was developed to extract the information for the pulsed eddy current. The voltage of the ultrasonic waves was carried on the pulsed eddy current voltage, and it was obtained by removing the pulsed eddy current voltage and extracting the time-domain testing signal of the A 1 mode EMAT. Through A 1 mode EMAT single detection that was used to obtain the pulsed eddy current and A 1 mode, the multi-parameter from the magnetoacoustic compound testing signal of the A 1 mode EMAT could be used to characterize the aluminum plate performance degradation. The detection accuracy of aluminum plate performance degradation was improved by the magnetoacoustic compound inspection compared with a single detection method.
26 February 2025 in Sensors and Actuators A: Physical
10 September 2025 in IEEE Transactions on Instrumentation and Measurement
HBVD-EMAT is an electromagnetic acoustic transducer (EMAT) composed of a Halbach magnet and a variable distance meander-line coil. By introducing a linear frequency-modulated (LFM) signal into the coil, wideband pulse compression surface waves can be generated. This article proposes an optimization method for HBVD-EMAT based on the fusion of orthogonal experiment and a multilayer perceptron (MLP) to enhance its performance in both the time and frequency domains. First, the finite-element simulation method is used to perform a four-factor, five-level orthogonal experiment on the size of the Halbach magnet. Then, the time- and frequency-domain response variables of the signal from the simulation results are extracted to analyze the orthogonal experimental results. The EMAT performance evaluation index is constructed based on this analysis. Finally, the MLP model is established with the performance evaluation index as the objective function. The orthogonal experimental results are used as training data to predict the optimal EMAT factor-level combination corresponding to the maximum objective function. The EMAT detection experimental results show that, compared with the nonoptimized HBVD-EMAT, the increase of incident surface wave generated by the optimized HBVD-EMAT in four response variables is 98%, 26%, 95%, and 10%, respectively. EMAT performance evaluation index is increased from 0.13 to 0.86. After optimization, the signal-to-noise ratio (SNR) of EMAT’s crack defect reflection signal and transmission signal is increased by 11.4 and 12.5 dB, respectively.