Mari Nieves Velasco Forte

Mari Nieves Velasco Forte

Auto-generated profile, based on publicly available information

Mari Nieves Velasco Forte

School of Biomedical Engineering and Imaging Sciences King's College London London UK

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2019 in Cardiology in the Young
Verified
Journal Article
Open access
PDF file
MFMari Nieves Velasco Forte
Mari Nieves Velasco Forte
THTarique Hussain
Tarique Hussain
ARArno Roest
Arno Roest
GGGorka Gomez
Gorka Gomez
Mrm JongbloedMrm Jongbloed
Mrm Jongbloed
IVIsrael Valverde
Israel Valverde
Advances in biomedical engineering have led to three-dimensional (3D)-printed models being used for a broad range of different applications. Teaching medical personnel, communicating with patients and relatives, planning complex heart surgery, or designing new techniques for repair of CHD via cardiac catheterisation are now options available using patient-specific 3D-printed models. The management of CHD can be challenging owing to the wide spectrum of morphological conditions and the differences between patients. Direct visualisation and manipulation of the patients’ individual anatomy has opened new horizons in personalised treatment, providing the possibility of performing the whole procedure in vitro beforehand, thus anticipating complications and possible outcomes. In this review, we discuss the workflow to implement 3D printing in clinical practice, the imaging modalities used for anatomical segmentation, the applications of this emerging technique in patients with structural heart disease, and its limitations and future directions.

1 December 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MFMari Nieves Velasco Forte
Mari Nieves Velasco Forte
KPKuberan Pushparajah
Kuberan Pushparajah
TSTobias Schaeffter
Tobias Schaeffter
IVIsrael Valverde
Israel Valverde
Kawal RhodeKawal Rhode
Kawal Rhode
SRSébastien Roujol
Sébastien Roujol
Cardiac catheterization is a common procedure in patients with congenital heart disease (CHD). Although cardiovascular magnetic resonance imaging (CMR) represents a promising alternative approach to fluoroscopy guidance, simultaneous high contrast visualization of catheter, soft tissue and the blood pool remains challenging. In this study, a novel passive tracking technique is proposed for enhanced positive contrast visualization of gadolinium-filled balloon catheters using partial saturation (pSAT) magnetization preparation. The proposed pSAT sequence uses a single shot acquisition with balanced steady-state free precession (bSSFP) readout preceded by a partial saturation pre-pulse. This technique was initially evaluated in five healthy subjects. The pSAT sequence was compared to conventional bSSFP images acquired with (SAT) and without (Non-SAT) saturation pre-pulse. Signal-to-noise ratio (SNR) of the catheter balloon, blood and myocardium and the corresponding contrast-to-noise ratio (CNR) are reported. Subjective assessment of image suitability for CMR-guidance and ideal pSAT angle was performed by three cardiologists. The feasibility of the pSAT sequence is demonstrated in two adult patients undergoing CMR-guided cardiac catheterization. The proposed pSAT approach provided better catheter balloon/blood contrast and catheter balloon/myocardium contrast than conventional Non-SAT sequences. It also resulted in better blood and myocardium SNR than SAT sequences. When averaged over all volunteers, images acquired with a pSAT angle of 20° to 40° enabled simultaneous visualization of the catheter balloon and the cardiovascular anatomy (blood and myocardium) and were found suitable for CMR-guidance in >93% of cases. The pSAT sequence was successfully used in two patients undergoing CMR-guided diagnostic cardiac catheterization. The proposed pSAT sequence offers real-time, simultaneous, enhanced contrast visualization of the catheter balloon, soft tissues and blood. This technique provides improved passive tracking capabilities during CMR-guided catheterization in patients.

6 November 2020 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
MFMari Nieves Velasco Forte
Mari Nieves Velasco Forte
SRSébastien Roujol
Sébastien Roujol
BRBram Ruijsink
Bram Ruijsink
IVIsrael Valverde
Israel Valverde
PDPhuoc Duong
Phuoc Duong
KPKuberan Pushparajah
Kuberan Pushparajah
Background: Improvements in outcomes for patients with congenital heart disease (CHD) have increased the need for diagnostic and interventional procedures. Cumulative radiation risk is a growing concern. MRI‐guided interventions are a promising ionizing radiation‐free, alternative approach.Purpose: To assess the feasibility of MRI‐guided catheterization in young patients with CHD using advanced visualization passive tracking techniques.Study Type: Prospective.Population: A total of 30 patients with CHD referred for MRI‐guided catheterization and pulmonary vascular resistance analysis (median age/weight: 4 years / 15 kg).Field Strength/Sequence: 1.5T; partially saturated (pSAT) real‐time single‐shot balanced steady‐state free‐precession (bSSFP) sequence.Assessment: Images were visualized by a single viewer on the scanner console (interactive mode) or using a commercially available advanced visualization platform (iSuite, Philips). Image quality for anatomy and catheter visualization was evaluated by three cardiologists with >5 years' experience in MRI‐catheterization using a 1–5 scale (1, poor, 5, excellent). Catheter balloon signal‐to‐noise ratio (SNR), blood and myocardium SNR, catheter balloon/blood contrast‐to‐noise ratio (CNR), balloon/myocardium CNR, and blood/myocardium CNR were measured. Procedure findings, feasibility, and adverse events were recorded. A fraction of time in which the catheter was visible was compared between iSuite and the interactive mode.Statistical Tests: T‐test for numerical variables. Wilcoxon signed rank test for categorical variables.Results: Nine patients had right heart catheterization, 11 had both left and right heart catheterization, and 10 had single ventricle circulation. Nine patients underwent solely MRI‐guided catheterization. The mean score for anatomical visualization and contrast between balloon tip and soft tissue was 3.9 ± 0.9 and 4.5 ± 0.7, respectively. iSuite provided a significant improvement in the time during which the balloon was visible in relation to interactive imaging mode (66 ± 17% vs. 46 ± 14%, P < 0.05).Data Conclusion: MRI‐guided catheterizations were carried out safely and is feasible in children and adults with CHD. The pSAT sequence offered robust and simultaneous high contrast visualization of the catheter and cardiac anatomy.Level of Evidence: 2Technical Efficacy Stage: 1

1 January 2019 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MFMari Nieves Velasco Forte
Mari Nieves Velasco Forte
IVIsrael Valverde
Israel Valverde
NPNanda Prabhu
Nanda Prabhu
TCTeresa Correia
Teresa Correia
SNSrinivas Ananth Narayan
Srinivas Ananth Narayan
MHMarkus Henningsson
Markus Henningsson
To investigate the use of respiratory motion compensation using image-based navigation (iNAV) with constant respiratory efficiency using single end-expiratory thresholding (CRUISE) for coronary magnetic resonance angiography (CMRA), and compare it to the conventional diaphragmatic navigator (dNAV) in paediatric patients with congenital or suspected heart disease. iNAV allowed direct tracking of the respiratory heart motion and was generated using balanced steady state free precession startup echoes. Respiratory gating was achieved using CRUISE with a fixed 50% efficiency. Whole-heart CMRA was acquired with 1.3 mm isotropic resolution. For comparison, CMRA with identical imaging parameters were acquired using dNAV. Scan time, visualization of coronary artery origins and mid-course, imaging quality and sharpness was compared between the two sequences. Forty patients (13 females; median weight: 44 kg; median age: 12.6, range: 3 months–17 years) were enrolled. 25 scans were performed in awake patients. A contrast agent was used in 22 patients. The scan time was significantly reduced using iNAV for awake patients (iNAV 7:48 ± 1:26 vs dNAV 9:48 ± 3:11, P = 0.01) but not for patients under general anaesthesia (iNAV = 6:55 ± 1:50 versus dNAV = 6:32 ± 2:16; P = 0.32). In 98% of the cases, iNAV image quality had an equal or higher score than dNAV. The visual score analysis showed a clear difference, favouring iNAV (P = 0.002). The right coronary artery and the left anterior descending vessel sharpness was significantly improved (iNAV: 56.8% ± 10.1% vs dNAV: 53.7% ± 9.9%, P < 0.002 and iNAV: 55.8% ± 8.6% vs dNAV: 53% ± 9.2%, P = 0.001, respectively). iNAV allows for a higher success-rate and clearer depiction of the mid-course of coronary arteries in paediatric patients. Its acquisition time is shorter in awake patients and image quality score is equal or superior to the conventional method in most cases.

27 March 2017 in Cardiology in the Young
Verified
Journal Article
Closed access
PDF file
MFMari N. Velasco Forte
Mari N. Velasco Forte
MNMohamed Nassar
Mohamed Nassar
NBNick Byrne
Nick Byrne
MVMiguel Silva Vieira
Miguel Silva Vieira
IVIsrael Valverde
Israel Valverde
THTarique Hussain
Tarique Hussain
ObjectiveMitral valve anatomy has a significant impact on potential surgical options for patients with hypoplastic or borderline left ventricle. Papillary muscle morphology is a major component regarding this aspect. The purpose of this study was to use cardiac magnetic resonance to describe the differences in papillary muscle anatomy between normal, borderline, and hypoplastic left ventricles.MethodsWe carried out a retrospective, observational cardiac magnetic resonance study of children (median age 5.36 years) with normal (n=30), borderline (n=22), or hypoplastic (n=13) left ventricles. Borderline and hypoplastic cases had undergone an initial hybrid procedure. Morphological features of the papillary muscles, location, and arrangement were analysed and compared across groups.ResultsAll normal ventricles had two papillary muscles with narrow pedicles; however, 18% of borderline and 46% of hypoplastic cases had a single papillary muscle, usually the inferomedial type. In addition, in borderline or hypoplastic ventricles, the supporting pedicle occasionally displayed a wide insertion along the ventricular wall. The length ratio of the superolateral support was significantly different between groups (normal: 0.46±0.08; borderline: 0.39±0.07; hypoplastic: 0.36±0.1; p=0.009). No significant difference, however, was found when analysing the inferomedial type (0.42±0.09; 0.38±0.07; 0.39±0.22, p=0.39). The angle subtended between supports was also similar among groups (113°±17°; 111°±51° and 114°±57°; p=0.99). A total of eight children with borderline left ventricle underwent biventricular repair. There were no significant differentiating features for papillary muscle morphology in this subgroup.ConclusionsThe superolateral support can be shorter or absent in borderline or hypoplastic left ventricle cases. The papillary muscle pedicles in these patients often show a broad insertion. These changes have important implications on surgical options and should be described routinely.