Youngjae Song

Youngjae Song

Auto-generated profile, based on publicly available information

Youngjae Song

VUNO Inc Seoul Republic of Korea

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Journal of Medical Internet Research
Verified
Journal Article
Open access
CHChangho Han
Changho Han
YSYoungjae Song
Youngjae Song
HLHong-Seok Lim
Hong-Seok Lim
YTYunwon Tae
Yunwon Tae
JJJong-Hwan Jang
Jong-Hwan Jang
DYDukyong Yoon
Dukyong Yoon
Background: When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. Objective: We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. Methods: We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. Results: The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. Conclusions: By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.

14 June 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
YSYoungJae Song
YoungJae Song
FSFrancisco Sepulveda
Francisco Sepulveda
Electromyography artefacts are a well-known problem in Electroencephalography studies (BCIs, brain mapping, and clinical areas). Blind source separation (BSS) techniques are commonly used to handle artefacts. However, these may remove not only EMG artefacts but also some useful EEG sources. To reduce this useful information loss, we propose a new technique for statistically selecting EEG channels that are contaminated with class-dependent EMG (henceforth called EMG-CCh). Methods: The EMG-CCh are selected based on the correlation between EEG and facial EMG channels. They were compared (using a Wilcoxon test) to determine whether the artefacts played a significant role in class separation. To ensure that promising results are not due to weak EMG removal, reliability tests were done. Results: In our data set, the comparison results between BSS artefact removal applied in two ways, to all channels and only to EMG-CCh, showed that ICA, PCA and BSS-CCA can yield significantly better (p<0.05) class separation with the proposed method (79% of the cases for ICA, 53% for PCA and 11% for BSS-CCA). With BCI competition data, we saw improvement in 60% of the cases for ICA and BSS-CCA. Conclusion: The simple method proposed in this paper showed improvement in class separation with both our data and the BCI competition data. Significance: There are no existing methods for removing EMG artefacts based on the correlation between EEG and EMG channels. Also, the EMG-CCh selection can be used on its own or it can be combined with pre-existing artefact handling methods. For these reasons, we believe this method can be useful for other EEG studies.

1 January 2004 in Computer-Aided Design and Applications
Verified
Journal Article
Open access
YSYoungjae Song
Youngjae Song
KLKunwoo Lee
Kunwoo Lee
Computer-Aided Design and Applications is an international journal on the applications of CAD and CAM. It publishes papers in the general domain of CAD plus in emerging fields like bio-CAD, nano-CAD, soft-CAD, garment-CAD, PLM, PDM, CAD data mining, CAD and the internet, CAD education, genetic algorithms and CAD engines. The journal is aimed at all developers and users of CAD technology to ptovide CAD solutions for various stages of design and manufacturing. The journal publishes all about Computer-Aided Design and Computer-Aided technologies.

20 February 2017
Verified
Conference Paper
Closed access
YSYoungJae Song
YoungJae Song
FSFrancisco Sepulveda
Francisco Sepulveda
This research investigated an online onset detection (i.e., ON state detection in asynchronous BCIs) method for BCIs by opening a message when it arrives in two different daily-life task scenarios (watching video and reading text). A new sound-production related cognitive task (Sound-production imagery, SI) was tested. Blind-source separation with canonical correlation analysis was used for artefact handling. Autoregressive coefficients, band power, common spatial patterns and discrete wavelet transform were used for feature extraction to cover all time, frequency, and spatial time-frequency domain. Linear discriminant analysis was used for classification. The averaged true-positive rate with six subjects was 88.9% in the watching video scenario and 78.9% in the reading text case. The average false-positive rates were 4.2% and 3.9%, respectively. In terms of task response speed, SI task recognition took 4.45s on average for an onset. From these results, the new SI task showed promising results for an online self-paced onset detection system compared to other similar studies.

7 February 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
YSYoungjae Song
Youngjae Song
FSFrancisco Sepulveda
Francisco Sepulveda
Background: Even though the BCI field has quickly grown in the last few years, it is still mainly investigated as a research area. Increased practicality and usability are required to move BCIs to the real-world. Self-paced (SP) systems would reduce the problem but there is still the big challenge of what is known as the ‘onset detection problem’. Methods: Our previous studies showed how a new sound-imagery (SI) task, high-tone covert sound production, is very effective for onset detection scenarios and we expect there are several advantages over most common asynchronous approaches used thus far, i.e., motor-imagery (MI): 1) Intuitiveness; 2) benefits to people with motor disabilities and, especially, those with lesions on cortical motor areas; and 3) no significant overlap with other common, spontaneous cognitive states, making it easier to use in daily-life situations. The approach was compared with MI tasks in online real-life scenarios, i.e., during activities such as watching videos and reading text. In our scenario, when a new message prompt from a messenger program appeared on the screen, participants watching a video (or reading text, browsing images) were asked to open the message by executing the SI or MI tasks, respectively, for each experimental condition. Results: The results showed the SI task performed statistically significantly better than the MI approach: 84.04% (SI) vs 66.79 (MI) True-False positive rate for the sliding image scenario, 80.84% vs 61.07% for watching video. The classification performance difference between SI and MI was found not to be significant in the text-reading scenario. Furthermore, the onset response speed showed SI (4.08 s) being significantly faster than MI (5.46 s). In terms of basic usability, 75% of subjects found SI easier to use. Conclusions: Our novel SI task outperforms typical MI for SP onset detection BCIs, therefore it would be more easily used in daily-life situations. This could be a significant step forward for the BCI field which has so far been mainly restricted to research-oriented indoor laboratory settings.

23 June 2021 in JMIR Preprints
Verified
Preprint
Open access
CHChangho Han
Changho Han
YSYoungjae Song
Youngjae Song
HLHong-Seok Lim
Hong-Seok Lim
YTYunwon Tae
Yunwon Tae
JJJong-Hwan Jang
Jong-Hwan Jang
DYDukyong Yoon
Dukyong Yoon
BACKGROUND When using a smartwatch to obtain electrocardiogram (ECG) signals from multiple leads, the device has to be placed on different parts of the body sequentially. The ECG signals measured from different leads are asynchronous. Artificial intelligence (AI) models for asynchronous ECG signals have barely been explored. OBJECTIVE We aimed to develop an AI model for detecting acute myocardial infarction using asynchronous ECGs and compare its performance with that of the automatic ECG interpretations provided by a commercial ECG analysis software. We sought to evaluate the feasibility of implementing multiple lead–based AI-enabled ECG algorithms on smartwatches. Moreover, we aimed to determine the optimal number of leads for sufficient diagnostic power. METHODS We extracted ECGs recorded within 24 hours from each visit to the emergency room of Ajou University Medical Center between June 1994 and January 2018 from patients aged 20 years or older. The ECGs were labeled on the basis of whether a diagnostic code corresponding to acute myocardial infarction was entered. We derived asynchronous ECG lead sets from standard 12-lead ECG reports and simulated a situation similar to the sequential recording of ECG leads via smartwatches. We constructed an AI model based on residual networks and self-attention mechanisms by randomly masking each lead channel during the training phase and then testing the model using various targeting lead sets with the remaining lead channels masked. RESULTS The performance of lead sets with 3 or more leads compared favorably with that of the automatic ECG interpretations provided by a commercial ECG analysis software, with 8.1%-13.9% gain in sensitivity when the specificity was matched. Our results indicate that multiple lead-based AI-enabled ECG algorithms can be implemented on smartwatches. Model performance generally increased as the number of leads increased (12-lead sets: area under the receiver operating characteristic curve [AUROC] 0.880; 4-lead sets: AUROC 0.858, SD 0.008; 3-lead sets: AUROC 0.845, SD 0.011; 2-lead sets: AUROC 0.813, SD 0.018; single-lead sets: AUROC 0.768, SD 0.001). Considering the short amount of time needed to measure additional leads, measuring at least 3 leads—ideally more than 4 leads—is necessary for minimizing the risk of failing to detect acute myocardial infarction occurring in a certain spatial location or direction. CONCLUSIONS By developing an AI model for detecting acute myocardial infarction with asynchronous ECG lead sets, we demonstrated the feasibility of multiple lead-based AI-enabled ECG algorithms on smartwatches for automated diagnosis of cardiac disorders. We also demonstrated the necessity of measuring at least 3 leads for accurate detection. Our results can be used as reference for the development of other AI models using sequentially measured asynchronous ECG leads via smartwatches for detecting various cardiac disorders.