Sergej Viktorovich Lazarenko

Sergej Viktorovich Lazarenko

Auto-generated profile, based on publicly available information

Sergej Viktorovich Lazarenko

Kursk State Medical University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Novosti Khirurgii
Verified
Journal Article
Closed access
KUKursk State Medical University
Kursk State Medical University
VLV.A. Lipatov
V.A. Lipatov
SLS.V. Lazarenko
S.V. Lazarenko
KSK.A. Sotnikov
K.A. Sotnikov
C№City Clinical Hospital №1
City Clinical Hospital №1
MEM.P. Ershov
M.P. Ershov

4 September 2024 in Russian Sklifosovsky Journal "Emergency Medical Care"
Verified
Journal Article
Open access
PDF file
VLV. A. Lipatov
V. A. Lipatov
SLS. V. Lazarenko
S. V. Lazarenko
DSD. A. Severinov
D. A. Severinov
ADA. A. Denisov
A. A. Denisov
OPO. V. Padalkina
O. V. Padalkina
   BACKGROUND. The development of new samples of local hemostatic agents is an intensively developing area of the modern industrial biotechnology due to a high need of clinical bases for such products. In addition to constant search for optimal substances used as a basis (collagen, cellulose and its derivatives, gelatin, etc.) for local hemostatic agents, methods for their comprehensive testing are also being developed.   AIM OF THE STUDY. To evaluate the hemostatic activity of multicomponent polymer sponge implants using the coagulometer method developed by the authors in an in vitro experiment.   MATERIAL AND METHODS. As research materials, new samples of multicomponent polymer sponge implants developed within the Laboratory of Experimental Surgery and Oncology of the Kursk State Medical University were used. The samples were based on marine collagen made from deep-sea squid in different ratios by weight with carboxymethylcellulose sodium salt (15/85, 25/75, 50/50). The hemostatic activity of these products was evaluated in the in vitro experiment using our method based on coagulometric measurement of blood clotting time of volunteer donors. Statistical processing of the data was carried out using methods of descriptive and variation statistics (Me [25; 75]). The validity of the difference was determined using the Mann–Whitney test (p ≤ 0,05).   RESULTS. The blood clotting time in experimental group No. 2 turned out to be 2.12 s less than in the control group (the tested samples of hemostatic agents were not added). Statistically significant differences were found when comparing the values of coagulation time in experimental groups No. 3 (2.98 s less) and No. 4 (2.37 s less) with the values of the control group (No. 1). A decrease in the blood clotting time indirectly proves the effectiveness of the products used, due to the formation of the blood clot in a shorter period of time. This suggests that when the hemostatic agents are used in bleeding conditions, the products will reduce the time and volume of bleeding due to their hemostatic activity.   CONCLUSION. Within the framework of the completed study, it was established that our method for assessing the hemostatic activity of local hemostatic agents, based on the evaluation of blood clotting time using electrocoagulometry, after grinding the tested samples, is easy to perform, accessible to most laboratories, and allows researchers to investigate the effectiveness of various forms of multicomponent polymer sponge implants. The development of multicomponent polymer sponge implants based on carboxymethylcellulose sodium salt and collagen seems to be a promising direction, since these products accelerate blood clotting time in the in vitro experiment.

3 July 2020 in I.P. Pavlov Russian Medical Biological Herald
Verified
Journal Article
Open access
PDF file
VLVyacheslav A. Lipatov
Vyacheslav A. Lipatov
DSDmitriy A. Severinov
Dmitriy A. Severinov
ADArtem A. Denisov
Artem A. Denisov
SLSergey V. Lazarenko
Sergey V. Lazarenko
NGNikolay N. Grigor’yEv
Nikolay N. Grigor’yEv
Taking into account the peculiarities of the blood supply to the liver and the structure of its parenchyma, and, as a result, considerable difficulties in providing reliable hemostasis without additional traumatization, a surgeon needs to be careful when performing a surgical manipulation. Despite a large number of modern methods for stopping parenchymal bleeding, many practi-tioners give preference to classic methods of hemostasis, including ligation of bleeding vessels in the bulk of the organ using specialized sutures. One of the most serious complications of the use of suture material is cutting of organ tissue, which leads to enhanced bleeding and expansion of the area of damage. At the moment, the tactics of choosing suture material for surgical procedures is empirical. In this context, the aim of this study was to assess the physico-mechanical properties of suture material regarding its structure, and to develop a criterion for choosing surgical sutures for surgical procedures. For the study, the liver was removed out of corpses of males of 35 to 40 years of age, after which separate sections of 7.574 cm in size were obtained from it. Then a wound 3 cm long and 2 cm deep was made. The wound was sutured with a simple interrupted suture without tightening, but with application of one simple half-node. For suturing, catgut, twisted capron and polyglycolide thread were used. Attention was paid to the maximal force applied at the moment of cutting (Fmax) and the degree of pulling the thread at the moment of cutting (Lu). The analysis of the data was based on comparison of Fmax and Lu parameters. This method permits to refuse from the empirical approach to the choice of suture material for operations on the liver, and to develop a criterion for choosing surgical sutures.

28 October 2019 in Journal of Experimental and Clinical Surgery
Verified
Journal Article
Open access
PDF file
VLVyacheslav Aleksandrovich Lipatov
Vyacheslav Aleksandrovich Lipatov
SLSergey Viktorovich Lazarenko
Sergey Viktorovich Lazarenko
DSDmitriy Andreevich Severinov
Dmitriy Andreevich Severinov
AUAlexander Aleksandrovich Ushanov
Alexander Aleksandrovich Ushanov
Background: One of the important unsolved problems of hepatobiliary surgery is to stop the bleeding of the parenchymal organ. The most promising means of local hemostasis are spongy implants made of various materials, the study of which is one of the leading directions in modern surgery. Nevertheless, despite the relevance of the research, there is no uniform classification of the structural features of such hemostatics. Aims: to study the features of the surface of the application of hemostatic implants based on collagen and Carboxymethylcellulose Sodium. Materials and methods: the authors performed light microscopy of the samples, photographing and subsequent processing of the photographs obtained using the trial version of the graphic editor Adobe Photoshop CS6 (Adobe Systems, San Jose, United States of America) to obtain black and white images by enhancing the contrast (+400 ), which excluded the possibility of false color definition. The black and white pixels were counted using the Altami Studio 3.4 program (Altami LLC, St. Petersburg, Russian Federation). Then, the real pixel size was converted into percentages using the trial version of Statistica 10.0 (Dell Software Company, Round Rock, United States of America). After that, the ratio of low areas of the implant (black pixels) to high (white pixels) was determined. Results: According to the data obtained, a classification was developed for the heterogeneity of the surface of the relief of hemostatic implants, according to which all of them can be divided into three groups: with weak, moderate and strong severity of the heterogeneity of the surface relief. Conclusions: when correlating the obtained results and selected groups, it was found out that the hemostatic sponge Tachocomb (Takeda Pharmaceuticals LLC, Linz, Austria) has a slightly pronounced heterogeneity of the surface relief, and the hemostatic collagen sponge (OJSC Luga Belkozin, Luga, Russian Federation) and a Carboxymethylcellulose based hemostatic sponge (developed in cooperation with Linteks LLC, St. Petersburg, Russian Federation) - moderately pronounced surface heterogeneity.

25 February 2020 in Journal of Experimental and Clinical Surgery
Verified
Journal Article
Open access
PDF file
VLVyacheslav Aleksandrovich Lipatov
Vyacheslav Aleksandrovich Lipatov
SLSergej Viktorovich Lazarenko
Sergej Viktorovich Lazarenko
DSDmitry Andreevich Severinov
Dmitry Andreevich Severinov
ATAnastasia Valeryevna Tarasova
Anastasia Valeryevna Tarasova
Abdominal trauma in 26.7-40.8% of cases is accompanied by trauma of parenchymal organs. The condition of the patient with liver injury in 75% of cases is complicated by the development of hemorrhagic shock. In surgery, to achieve local hemostasis, the most promising method is the topical use of application hemostatic agents, while the composition of such funds determines the effectiveness of hemostasis. The aim of the study is to assess the histological characteristics of the liver using new samples of polymeric hemostatic materials in the experiment in vivo. Materials and methods. As research material was used hemostatic sponge based on natrocarbonatite (Na-CMC) (developed jointly with Linteks, Russia. Saint-Petersburg.) In the experimental groups of laboratory animals under general anesthesia produced a median laparotomy and simulated planar surface injury to the liver. Parenchymal bleeding was stopped by applying application hemostatic materials. An autopsy of the injured area of the liver was performed together with an implanted hemostatic agent. The thickness of the capsule, the size of the Central veins of the liver, the number of dual-core hepatocytes, the size of hepatocytes and their nuclei were measured. Results. The indicator of the area of hepatocytes of groups No. 4 and No. 5 are as close as possible to group No. 1 indicators. Similar to the area of hepatocytes, difference of the area of their kernels in groups No. 6, No. 7 are statistically not significant in comparison with group No. 1. In groups No. 6 and No. 5 the area of kernels is authentically increased, but does not reach values of control group. The greatest statistically significant increase in thickness of the capsule in comparison with group No. 1, group No. 2 and No. 3 was observed in group No. 4. The area of the central vein is authentically increased in comparison with control group in groups No. 2, No. 3 and No. 6. The number of two-nuclear hepatocytes in comparison with norm, group No. 4 and group No. 1 is reliable above in groups No. 6 and No. 7. Conclusion. Histologic reorganizations, changes of morphological structure in places of a trauma and implantation of the tested samples are less expressed when using haemo static implants of experimental groups No. 3-№6 (styptic local means on the basis of Na-KMTs with addition of aminocaproic, acetilsalicylic and aminoacetic acids).

30 March 2025 in Актуальные проблемы медицины
Verified
Journal Article
Open access
KUKursk State Medical University
Kursk State Medical University
VLViacheslav A. Lipatov
Viacheslav A. Lipatov
SLSergey V. Lazarenko
Sergey V. Lazarenko
AIAlexander V. Ivanov
Alexander V. Ivanov
TKTatyana N. Kudryavtseva
Tatyana N. Kudryavtseva
VNVictoria A. Nikulochkina
Victoria A. Nikulochkina
The aim of the study was to evaluate the dynamics of hydroxyproline concentration after subcutaneous implantation of local hemostatic agents in an in vivo experiment. The experiment was carried out on 210 male Wistar rats divided into seven groups (30 animals in each). Under inhalation anesthesia, an incision was made in the skin and subcutaneous fat of laboratory animals along the scapular line, then a tool was inserted into the wound, forming a pocket. Samples were implanted into the resulting depression according to the division into groups. To assess the dynamics of hydroxyproline concentrations, animals were taken out on the 7th, 14th and 28th days. After CO2-induced euthanasia, the area of the periprosthetic capsule was isolated. After sample preparation of the biomaterial, the concentration of hydroxyproline was determined by chromatographic method. The statistical significance of differences was determined by calculating the Kruskal-Wallis test. In all experimental groups, a direct correlation was revealed between the concentration of 4-hydroxy-L-proline and the timing of elimination. On the 28th day, the highest concentration of hydroxyproline was detected in experimental groups No. 5 (0.0285), 7 (0.0160), 3 (0.0110), and the lowest in groups No. 4 (0.0058), 6 (0.0058), 2 (0.0078), 1 (0.0082). These indicators can be associated with the high collagen content in implants, which provokes a more pronounced local reaction of the macroorganism. Subcutaneous implantation of combined hemostatic sponges based on NaCMC and deep-sea squid collagen statistically significantly (p ≤ 0.05) provoke a less pronounced tissue reaction compared with control and comparison groups.