27 February 2018 in IEEE Transactions on Power Electronics
A 1270 Hz resonance occurred between ±350 kV/ 1000 MW Luxi back-to-back voltage source converter based high-voltage dc transmission (VSC-HVDC) converter and the 525 kV ac grid after disconnection of several ac transmission lines. To understand the resonance and find a solution, the impedance-based stability analysis model considering different equipment is first established. Then, the resonance is analyzed and repeated in the simulation based on the established model. The system stability can be judged by the ratio of grid impedance to the equivalent impedance of all parallel-connected equipment with the converter. To evaluate the occurrence and risk of resonance, the frequency range where the impedance has a negative-real-part has been searched and studied. In order to narrow the negative-real-part region to avoid potential resonance, solutions such as control strategy improvement and passive or active impedance adapter may be applicable and are discussed. For a complex system containing various equipment, the equipment can be divided into several subsectors to avoid modeling all possible combinations of equipment, which can be exhausting. And analysis has shown sufficient but not necessary condition to stabilize the system is to avoid the negative-real-part region in each sector.
5 June 2014 in IEEE Transactions on Industrial Informatics
Delay is inevitable in digital-controlled system and the delay will change system phase-frequency characteristic, thus affecting system stability. The system stability of inductor-capacitor-inductor (LCL)-type grid-connected inverter with single-loop control based on inverter-side current and single-loop control based on grid-side current is analyzed both in continuous and discrete domains. The influence of delay time on system stability is systematically studied. A delay time control method that is capable of adjusting delay time is further proposed to improve system stability. The proposed delay time control method is applied in the experiment, making an unstable system to be stable, and verifies the analysis result and proposed method.
2 January 2014 in IEEE Transactions on Power Electronics
This letter establishes the stationary frame equivalent model of proportional-integral (PI) controller in dq synchronous frame. Although both PI controller in dq synchronous frame and proportional-resonant (PR) controller in stationary frame achieve zero steady-state error when tracing fundamental frequency reference, their amplitude and phase characteristics differ greatly from each other except for fundamental frequency. Using stationary frame PR controller to replace PI controller in dq synchronous frame directly leads to analytical errors, especially in low frequency stage. Another straightforward analysis method is to use stationary frame PI controller to replace PI controller in dq synchronous frame, however the coupling terms in dq synchronous frame are ignored and the approximation is not accurate. The accurate stationary frame equivalent model of PI controller is established. For system controlled in dq synchronous frame, the established model can be used to precisely predict system performance and thus guides control parameters design process. Theoretical analysis is presented and validity of the model is evaluated by simulation.
26 October 2017 in IEEE Transactions on Industrial Informatics
When single-loop inverter-side current control is used in LCL-type inverters, there may be more than one stable regions with regard to computation delay in control path. The system is stable if computation delay is small enough, but it, named as the first stable region, may be too narrow to finish the control codes in high-frequency system. On the other hand, the second stable region is highly sensitive to the grid impedance variation and is hardly applicable in weak grids. To deal with the situation, this paper investigates the influence of the capacitor voltage feedforward on the system stability considering flexible computation delay in feedforward path. It is found that the capacitor voltage feedforward is able to suppress the resonance of LCL filter. However a new resonance may arise if computation delay is not carefully handled. The influence of computation delay in both forward path and feedforward path on system stability are systematically analyzed. The analytical results show that after applying feedforward control with optimized delay, the system stability is greatly improved and is not sensitive to the grid impedance variation. The simulation and experiment results verify the analytical results.
30 May 2014 in IEEE Transactions on Industry Applications
This paper presents a power decoupling method based on a four-switch three-port dc/dc/ac converter in dc microgrid. The proposed topology has three interfaces which can be connected with a dc source, a capacitor, and an ac port. With a corresponding power flow control method, this converter can decouple the low-frequency ripple power which is necessary for the ac port and undesirable for the dc source with small capacitor. The proposed topology is compact and cost-effective because, compared with the H-bridge inverter, no extra switches or devices are required. With the model of the proposed dc/dc/ac converter, a power control method with two inductors' current control is presented for power decoupling. In addition, the control parameters are designed as well. Experimental results on the laboratory prototype verified the feasibility of the proposed topology and the designed power control method.
13 August 2012 in IEEE Transactions on Industrial Informatics
This paper proposes a three-phase grid impedance detection method based on dual-frequency harmonic current injection for islanding detection. Grid impedance detection based on single harmonic current injection is reliable in three-phase impedance balanced grid. However, under impedance unbalanced condition, the harmonic voltage caused by the injected symmetric harmonic current is asymmetric, which affects the calculation of grid impedances and even leads to failed detection. The method based on dual-frequency harmonic current injection is injecting two non-characteristic symmetric harmonic currents, and then according to the different harmonic voltages caused by different frequency harmonic currents, all three-phase impedances can be calculated accurately. The implementing algorithm of the presented method is derived and its performance is analyzed in detail. Simulation and experiments are carried out under grid impedance balanced and unbalanced conditions. Theoretical analysis and experiment results proved that the proposed method is feasible.