Cap and pin insulators are widely used in electricity transmission towers in power systems and are one of their key functional elements. This paper reports on a successful application of using electric field as an index to detect and locate shorted insulator units in a cap and pin string. Electro-optical (EO) probes were used to measure the electrical field, and a six-axis robotic arm, holding the probes, enabled electrical field mapping at different spatial locations. The electric field distribution was first plotted according to the measurements performed by EO probes travelling along straight lines parallel to the string, and then a closer examination between insulator sheds was conducted to evaluate the possibility of higher accuracy locating of shorted insulator units. The measured changes in electric field distribution were compared with predictions from corresponding electrostatic finite element analysis (FEA) models, confirming the ability of locating shorted units in the string based on observation of the field spatial distribution change. The electric field monitoring system was also further developed to achieve operator-free and automated data acquisition and recording. The reported methodology exhibits promising potential in live condition monitoring of insulator strings in high voltage (HV) towers.
The importance of electrical trees and interfacial electrical track growth as aging processes in high voltage polymeric insulation systems is well established. It is argued that the majority of testing using needle-plane electrode systems with small insulation gaps is not representative of insulation in high voltage service conditions. In particular, the relationship between partial discharge magnitude, tree length and sample scale is considered. Track growth has been considered in laboratory samples with a 90 mm gap between electrodes. This arrangement allows the channels to grow independent of their proximity to the electrodes. The applied voltage and sample thickness, as well as the electrical field, are critical parameters to be considered. The growth of channels here was voltage limited. Smaller and lower voltage tests cannot replicate this behavior because in small samples tree channels are always in close proximity to, and dominated by, the electrode geometry.
28 November 2025 in Composites Part B: Engineering
Urban populations are particularly vulnerable to heat-related mortality and morbidity. Climate-responsive urban design, which can include development of green and bluespaces, has the potential to offset climate change-related impacts. Compared to greenspaces, the effects of bluespaces on urban temperatures have received comparatively little attention, with uncertainty regarding the magnitude of urban cooling. In this study, we develop an energy balance model to estimate the thermal effects of canals and apply this to the canal network of Great Britain and Ireland. Here we show that the modelled canals provide an average annual daytime cooling effect of ~0.8 °C (0.7 – 1 °C) within the immediate vicinity of the canal network, with more pronounced cooling during spring and early summer (~1.2 – 1.4 °C) and during heatwaves (~1.5 – 2.3 °C). While thermal effects are not exclusively positive, our results indicate that canals can improve thermal comfort and reduce heat risk, with related benefits for population health and wellbeing.
26 May 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Long-term degradation of polymer insulation systems is a major reliability issue for the electrical generation and supply industries. In the laboratory, unrepresentative needle geometries are ubiquitously used to generate and study electrical tracks and trees. This paper describes how tree-like structures and tracking can be generated, without the use of needles, from an engineered cavity at the interface between two polymers. Under these conditions trees can be grown at relatively low average applied fields of 2 kV/mm. Characteristic partial discharge activity and light emission are associated with the generation of tree channels. A model describing the growth of such defects is presented containing five stages. The paper provides insight into how interfacial stress can lead to failures in high-voltage systems. X-Ray Computed Tomography (XCT) was used to characterize the channel structures and establish a correlation between PD and the shape and type of channel. The use of such voids may present an alternative and improved platform, compared to traditional needle-plane geometries, for investigation of insulation failure.
To enable the continued development of power transmission cabling, an understanding of the processes which result in their failures is essential. In order to do so, powerful analysis techniques are required. However, those which consider chemical degradation are lagging behind those for visible degradation. This paper presents the Atomic Force Microscopy - Infrared Spectroscopy (AFM-IR) chemical analysis technique, which can provide surface chemical analysis with resolution of ~50 nm across the infrared spectrum. Two cases are considered: interfacial tracking between epoxy and silicone rubber, and the degraded region formed in front of a needle tip in the electrical tree initiation process. The results obtained using AFM-IR are compared to the outcomes from other techniques. It is found that AFM-IR offers a unique and powerful insight into visible and non-visible degradation of solid dielectrics.