Background: Breath‐holding (BH) for cine balanced steady state free precession (bSSFP) imaging is challenging for patients with impaired BH capacity. Deep learning‐based reconstruction (DLR) of undersampled k‐space promises to shorten BHs while preserving image quality and accuracy of ventricular assessment.Purpose: To perform a systematic evaluation of DLR of cine bSSFP images from undersampled k‐space over a range of acceleration factors.Study Type: Retrospective.Subjects: Fifteen pectus excavatum patients (mean age 16.8 ± 5.4 years, 20% female) with normal cardiac anatomy and function and 12‐second BH capability.Field Strength/Sequence: 1.5‐T, cine bSSFP.Assessment: Retrospective DLR was conducted by applying compressed sensitivity encoding (C‐SENSE) acceleration to systematically undersample fully sampled k‐space cine bSSFP acquisition data over an acceleration/undersampling factor (R) considering a range of 2 to 8. Quality imperceptibility (QI) measures, including structural similarity index measure, were calculated using images reconstructed from fully sampled k‐space as a reference. Image quality, including contrast and edge definition, was evaluated for diagnostic adequacy by three readers with varying levels of experience in cardiac MRI (>4 years, >18 years, and 1 year). Automated DL‐based biventricular segmentation was performed commercially available software by cardiac radiologists with more than 4 years of experience.Statistical Tests: Tukey box plots, linear mixed effects model, analysis of variance (ANOVA), weighted kappa, Kruskal–Wallis test, and Wilcoxon signed‐rank test were employed as appropriate. A P‐value <0.05 was considered statistically significant.Results: There was a significant decrease in the QI values and edge definition scores as R increased. Diagnostically adequate image quality was observed up to R = 5. The effect of R on all biventricular volumetric indices was non‐significant (P = 0.447).Data Conclusion: The biventricular volumetric indices obtained from the reconstruction of fully sampled cine bSSFP acquisitions and DLR of the same k‐space data undersampled by C‐SENSE up to R = 5 may be comparable.Evidence Level: 3Technical Efficacy: Stage 1
Purpose of review: Significant improvements in the diagnosis and management of patients with congenital heart disease (CHD) have led to improved survival. These patients require life-long noninvasive evaluation. The use of advanced imaging such as cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CCT) has increased to support this need. The purpose of this review is to discuss the basics of advanced cardiac imaging, indications and review the recent innovations. Recent findings: Recent literature has demonstrated the increasing reliance of advanced imaging for CHD patients. In addition, research is focusing on CMR techniques to shorten scan time and address previous limitations that made imaging younger and sicker patients more challenging. CCT research has involved demonstrating high-quality images with low radiation exposure. Advances in digital technology have impacted the interactivity of 3D imaging through the use of virtual and augmented reality platforms. With the increased reliance of advanced imaging, appropriate use criteria have been developed to address possible under or over utilization. Summary: The utilization of advanced cardiac imaging continues to increase. As CMR and CCT continue to grow, increased knowledge of these modalities and their usage will be necessary for clinicians caring for CHD patients.
18 July 2019 in The International Journal of Cardiovascular Imaging