Shijun Gao

Shijun Gao

Auto-generated profile, based on publicly available information

Shijun Gao

Department of Orthopedics, Third Hospital of Hebei Medical University, Shijiazhuang, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2018 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
XZXiaozuo Zheng
Xiaozuo Zheng
YHYang Hu
Yang Hu
PXPeng Xie
Peng Xie
MCMeijuan Cui
Meijuan Cui
XMXuelin Ma
Xuelin Ma
SGShijun Gao
Shijun Gao

21 November 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
XZXiaozuo Zheng
Xiaozuo Zheng
YHYang Hu
Yang Hu
PXPeng Xie
Peng Xie
TLTong Li
Tong Li
YFYu-E Feng
Yu-E Feng
SGShijun Gao
Shijun Gao
Background: There is no consensus as to the choice of grafts for primary anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare the clinical and second-look arthroscopic outcomes after ACL reconstruction by use of autograft, hybrid graft, and γ-irradiated allograft. Methods: Ninety-seven patients who underwent second-look arthroscopy after ACL reconstruction with autografts (28 patients, hamstring autograft), hybrid grafts (32 patients, hamstring autograft augmented with γ-irradiated tibialis anterior tendon allograft), or γ-irradiated allografts (37 patients, tibialis anterior tendons) were included in this study. The clinical outcomes were compared by using Lysholm score, International Knee Documentation Committee (IKDC) score, and Tegner activity score, and the side-to-side differences of KT-1000 measurement. Second-look arthroscopic findings were compared in terms of synovial coverage and graft tension. Results: There were no statistical significances among the three groups in Lysholm score, IKDC score, or Tegner activity score (P > 0.05). The KT-1000 examination showed more anterior laxity in the γ-irradiated allograft group than in the autograft or hybrid graft groups (P = 0.006, and P = 0.013, respectively). Two patients in the autograft group, 2 patients in the hybrid graft group and 4 patients in the allograft group were evaluated as graft failure on second-look arthroscopy. The synovial coverage was superior in the autograft group than that in the hybrid graft group or the allograft group (P = 0.013 and P = 0.010, respectively), and was comparable between the hybrid graft group and allograft group (P = 0.876). With regard to graft tension, the autograft group and hybrid group were comparable (P = 0.883) but showed better results than the allograft group (P = 0.011 and P = 0.007, respectively). Conclusion: The hamstring autografts and hybrid grafts used for ACL reconstruction produced equal efficacy but provided better knee stability than allografts. In addition, the hamstring autografts showed better synovial coverage than the other two graft types.

3 September 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
ZXZheshu Xu
Zheshu Xu
YDYunlong Dong
Yunlong Dong
YFYu-E Feng
Yu-E Feng
PXPeng Xie
Peng Xie
JGJuyuan Gu
Juyuan Gu
XZXiaozuo Zheng
Xiaozuo Zheng
Background: The surgical technique for treatment of tibial avulsion fractures of the posterior cruciate ligament (PCL) remains challenging due to the deep-located lesion and the complexity of the anatomy. The purpose of this study was to report preliminary results of an arthroscopic technique in patients with the “hinged” type PCL tibial avulsion fractures. Methods: Twenty-eight patients with the displaced “hinged” fractures with elevation of the posterior aspect of the bony fragment were arthroscopically treated. The bony fragment was reducted and fixed with the sutures passing through only one single tibial tunnel. The clinical outcomes were assessed by Lysholm score, Tegner activity score, and the side-to-side differences of KT-1000 measurement. The reduction and union of the fracture were assessed by radiography of the knee. Results: Patients were followed up for a mean of 19 (12 to 24) months. There were no surgery-related complications, and all patients regained normal range of motion of the knees at the last follow-up. The Lysholm score significantly increased from preoperative 14.78 ± 8.23 to postoperative 96.96 ± 3.62 (P = 0.000). The Tegner score was 6.78 ± 1.35 pre-injury and 6.48 ± 1.20 at the last follow-up with no statistical difference (P = 0.688). The KT-1000 side-to-side differences significantly decreased from 8.26(SD 1.86; 6 to 12) pre-operatively to 0.91 (SD 0.85; 0 to 3) (P = 0.000). X-rays showed that satisfactory reduction and solid union was achieved in all patients. Conclusion: The arthroscopic suture fixation through single-tibial tunnel technique yielded good clinical and radiographic outcome for treatment of displaced “hinged” type of PCL avulsion fractures.

22 July 2016 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
XZXiaozuo Zheng
Xiaozuo Zheng
TLTong Li
Tong Li
JWJuan Wang
Juan Wang
JDJiangtao Dong
Jiangtao Dong
SGShijun Gao
Shijun Gao
The medial collateral ligament (MCL) is the main static stabilizer of the medial knee. The surgical treatment was recommended in cases with serious medial collateral ligament insufficiency combined with multi-ligament injuries and chronic symptomatic medial instability. Several surgical techniques have been described for the MCL reconstruction, while potential problems including donor site morbidity, complicated procedure, and high risk of femoral tunnel collision were reported. In order to minimize such potential limitations, we describe a new medial reconstruction technique for MCL injury using bone-patellar tendon-bone (BPTB) allograft. A longitudinal incision at the medial knee was made. The centers of femoral and tibial attachments were gained through repeated isometricity test. Then, the bone grooves were made around the femoral and tibial centers. The appropriate BPTB allograft was selected, and both ends were trimmed. The prepared bone blocks were embedded into the grooves and fixed with cancellous screws. The programmed rehabilitation exercises were performed after the operation. A strong graft and bone-to-bone healing on both femoral and tibial attachment sites were obtained, and femoral tunnel collision during multi-ligament reconstruction was avoided. Satisfactory valgus and rotatory stability were gained. This novel MCL reconstruction technique using BPTB allograft can be safely performed, and the clinical outcome was favorable with satisfactory valgus and rotatory stability. More cases and additional follow-up results are needed to verify the overall effect of this technique.

21 June 2018 in Experimental and Therapeutic Medicine
Verified
Journal Article
Open access
PDF file
XZXiaozuo Zheng
Xiaozuo Zheng
WXWei Xu
Wei Xu
JGJuyuan Gu
Juyuan Gu
YHYang Hu
Yang Hu
MCMeijuan Cui
Meijuan Cui
SGShijun Gao
Shijun Gao
Preconditioning of the grafts prior to implantation into the knee is considered to reduce the loss of tension caused by graft viscoelasticity after anterior cruciate ligament reconstruction. The present study analyzed the impacts of different preconditioning forces on the biomechanical properties of the γ‑irradiated deep frozen tendon allografts. A total of 36 tendon grafts were randomly divided into three groups and were preconditioned at 80 N (group 1), 160 N (group 2) and 320 N (group 3) for 10 min. Subsequently, the grafts were gradually completely relaxed for 1 min and subsequently received 25 cyclic loads of 0‑80 N. Afterwards, the grafts were loaded to 80 N, which was maintained for 30 min. Finally, load was gradually increased until ultimate failure at maximum load (UFML) was obtained. There were significant differences in the stiffness and UFML values between the 3 groups (all P<0.05). The graft stiffness in group 3 significantly increased compared with the other 2 groups, and the stiffness of group 2 grafts increased compared with group 1. The UFML in group 3 was significantly lower compared with groups 1 and 2, while there was no significant difference between groups 1 and 2. In the present study, the results suggested that increasing the initial tension could effectively reduce the loss of stiffness due to viscoelasticity for the γ‑irradiated deep frozen allogeneic tendon grafts. However, overloaded initial tension decreased the tensile strength.