Russell J. Gardner

Russell J. Gardner

Auto-generated profile, based on publicly available information

Russell J. Gardner

Idaho National Lab. (INL), Idaho Falls, ID (United States)

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
WJWen Jiang
Wen Jiang
JHJason D. Hales
Jason D. Hales
BSBenjamin W. Spencer
Benjamin W. Spencer
BCBlaise P. Collin
Blaise P. Collin
ASAndrew E. Slaughter
Andrew E. Slaughter
RGRussell Gardner
Russell Gardner

1 January 2021 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
GPG. Pastore
G. Pastore
RWR.L. Williamson
R.L. Williamson
RGR.J. Gardner
R.J. Gardner
SNS.R. Novascone
S.R. Novascone
JTJ.B. Tompkins
J.B. Tompkins
JHJ.D. Hales
J.D. Hales

1 March 2021 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
GPG. Pastore
G. Pastore
KGK.A. Gamble
K.A. Gamble
RWR.L. Williamson
R.L. Williamson
SNS.R. Novascone
S.R. Novascone
RGR.J. Gardner
R.J. Gardner
JHJ.D. Hales
J.D. Hales

29 June 2018
Verified
Report
Open access
PDF file
BSBenjamin W. Spencer
Benjamin W. Spencer
RWRichard L. Williamson
Richard L. Williamson
ALAlexander D. Lindsay
Alexander D. Lindsay
FKFande Kong
Fande Kong
RGRussell J. Gardner
Russell J. Gardner
CUCetin Unal
Cetin Unal
Early in its development, the primary emphasis of efforts to improve the Bison fuel performance code were focused on initial development of new capabilities. As Bison has matured and become adopted by a wider set of users, it has become clear that a number of robustness issues needed to be addressed to ensure that the code can reliably produce a converged solution. This need became particularly evident when a recent effort by Westinghouse Electric Company to simulate all of the fuel rods in a reactor using Bison resulted in approximately 30\% of the models failing to run to completion because of lack of convergence or other errors that were encountered. It is important to emphasize that there was no evidence that Bison generated results that were incorrect for the set of models exercised. In many cases, issues such as those encountered could be addressed by adjusting solver-related parameters. However, there is no question that for Bison to become widely adopted for production work, it needs to be inherently far more robust than it was. Because of this, a concerted effort was undertaken to improve Bison's robustness, or its ability to reliably obtain converged solutions under a wider variety of conditions.more » As a result of this work, a number of high-priority areas for improvement for modeling light water reactor (LWR) fuel rods have been identified and addressed. As a result of this work, the number of failing Bison analyses in the aforementioned set of simulations for a full core has been reduced to a fraction of a percent. In addition, the robustness of Bison models using the VERA core simulator has been significantly improved. This is important because all of the Bison models representing individual fuel rods must run to completion successfully for the full core model to run to completion. This report provides summaries of the identified sources of robustness issues in Bison and the development that was done to resolve these issues. It also summarizes the addition of new capabilities to address deficiencies in Bison's ability to include needed aspects of LWR fuel behavior, and improvements that were made to improve Bison's solution efficiency. « less

29 September 2017
Verified
Report
Closed access
PDF file
GPG. Pastore
G. Pastore
KGK. A. Gamble
K. A. Gamble
RGR. J. Gardner
R. J. Gardner
JTJ. B. Tompkins
J. B. Tompkins
WLW. Liu
W. Liu
RWRichard L. Williamson
Richard L. Williamson
Since 2013 CASL has been planning and working towards a PWR LOCA Challenge Problem. Since BISON is the CASL fuel rod simulation platform, it plays a central role in that activity. The goal of the FY-17 CASL milestone reported here was to develop an Experimental Benchmark for LOCA analysis using BISON. Activities encompassed both code development and validation. This report provides a current snapshot of BISON’s capability for LOCA behavior including: 1) a summary of code extensions to facilitate accident analysis, 2) a series of separate effects tests, and 3) initial code validation to complex integral rod LOCA behavior. Conclusions from each of these main activities are summarized below. The key material and behavior models required to address transient high-temperature phenomena occurring during LOCAs in a standard PWR have now been implemented in BISON. These apply specifically to UO2 fuel, Zircaloy cladding and water coolant. During FY-17 important new capability to address axial UO2 fuel relocation (for 1.5D geometry) and account for oxidation energy deposition in cladding, were included. Planned future development efforts include extending the axial fuel relocation model from 1.5D to 2D/3D and improving BISON’s fission gas release model to include transient gas release associated with the highmore » burnup structure (HBS) in high burnup fuel. Additionally, investigation of potential anisotropic creep behavior in Zircaloy cladding is planned, assuming sufficient experimental data are available to support this effort. A substantial number of separate effects validation cases (42 tests from 3 experimental series) have been completed to compare BISON predictions to measured ballooning and burst behavior for Zircaloy cladding. Such experiments include a wide variety of pressures, temperatures and loading rates. In general, BISON predictions of burst temperature, pressure and burst time are very reasonable. For one experimental series, however, involving both very high temperatures and strain rates, BISON systematically over-predicts the cladding hoop strain. Investigation of this discrepancy is an important and planned activity. With another experiment an effort was made to investigate 3D cladding response due to an azimuthal temperature variation. Results indicated 3D effects are potentially important in fuel rod analysis during LOCAs and will be further investigated in the future. BISON validation to a series of integral fuel rod experiments has also been completed. These experiments involve all fuel and cladding phenomena relevant to LOCA conditions, and can include complexities associated with irradiated fuel relative to fresh fuel. Such experiments also generally include complex thermal-hydraulic boundary conditions. Four experiments (6 rods) have been considered to date including simulated fuel (ZrO2) and both fresh and high-burnup UO2. Test rods ranged from rodlets to full length commercial PWR fuel rods. As with the separate effects experiments, BISON predictions of burst temperature, pressure and burst time are generally very reasonable. Comparisons to cladding peak strain and rod outer diameter axial profiles are less satisfactory, and identify material models and possibly modeling approximations (e.g., 2D-RZ vs 3D geometries) requiring additional investigation. Validation of BISON for integral rod LOCA behavior is by no means complete, with additional cases planned. « less

10 October 2018
Verified
Report
Closed access
PDF file
RGRussell J. Gardner
Russell J. Gardner
CFCharles P. Folsom
Charles P. Folsom
WJWen Jiang
Wen Jiang
JHJason D. Hales
Jason D. Hales
BSBenjamin W. Spencer
Benjamin W. Spencer
This report summarizes Bison development and application in three areas: • Development of the layered 1D approach to permit its use with the reference residual convergence criterion that is widely used for 2D and 3D Bison simulations. For higher-dimensional simulations, this approach has resulted in significant improvements in robustness and solution efficiency, and it is expected to result in similar benefits for 1D simulations of light water reactor (LWR) rods. • A study on the effects of the chosen convergence tolerances on solution difficulty and accuracy was performed for a prototypical layered 1D simulation of an LWR fuel rod. The effect of convergence tolerance on iteration counts, run times, and several quantities of interest in the solution are compared for the various convergence tolerance. This study will be helpful for guiding the choice of convergence tolerances. • A demonstration of a reactivity insertion accident (RIA) simulation with Bison within the coupled VERA code was performed. The MPACT neutron transport code and the CTF thermal-hydraulic code provided inputs to Bison for a postulated control rod ejection scenario. This demonstrates the ability of the VERA environment to consider coupling effects not only for normal operation, but for accident conditions.